Luca Neri

Dr. Luca Neri

Johns Hopkins University, Baltimore, Maryland, USA
+1
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2016 in Journal of Micro and Bio Robotics
Verified
Journal Article
Open access
PDF file
GCGastone Ciuti
Gastone Ciuti
RCRenato Calio'
Renato Calio'
DCDomenico Camboni
Domenico Camboni
Luca NeriLuca Neri
Luca Neri
FBF. Bianchi
F. Bianchi
PDP. Dario
P. Dario
Digestive diseases are a major burden for society and healthcare systems, and with an aging population, the importance of their effective management will become critical. Healthcare systems worldwide already struggle to insure quality and affordability of healthcare delivery and this will be a significant challenge in the midterm future. Wireless capsule endoscopy (WCE), introduced in 2000 by Given Imaging Ltd., is an example of disruptive technology and represents an attractive alternative to traditional diagnostic techniques. WCE overcomes conventional endoscopy enabling inspection of the digestive system without discomfort or the need for sedation. Thus, it has the advantage of encouraging patients to undergo gastrointestinal (GI) tract examinations and of facilitating mass screening programmes. With the integration of further capabilities based on microrobotics, e.g. active locomotion and embedded therapeutic modules, WCE could become the key-technology for GI diagnosis and treatment. This review presents a research update on WCE and describes the state-of-the-art of current endoscopic devices with a focus on research-oriented robotic capsule endoscopes enabled by microsystem technologies. The article also presents a visionary perspective on WCE potential for screening, diagnostic and therapeutic endoscopic procedures.

16 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Luca NeriLuca Neri
Luca Neri
MOMatt T. Oberdier
Matt T. Oberdier
KAKirsten van Abeelen
Kirsten van Abeelen
Luca MenghiniLuca Menghini
Luca Menghini
ETEthan Tumarkin
Ethan Tumarkin
HHHenry R. Halperin
Henry R. Halperin
Worldwide, population aging and unhealthy lifestyles have increased the incidence of high-risk health conditions such as cardiovascular diseases, sleep apnea, and other conditions. Recently, to facilitate early identification and diagnosis, efforts have been made in the research and development of new wearable devices to make them smaller, more comfortable, more accurate, and increasingly compatible with artificial intelligence technologies. These efforts can pave the way to the longer and continuous health monitoring of different biosignals, including the real-time detection of diseases, thus providing more timely and accurate predictions of health events that can drastically improve the healthcare management of patients. Most recent reviews focus on a specific category of disease, the use of artificial intelligence in 12-lead electrocardiograms, or on wearable technology. However, we present recent advances in the use of electrocardiogram signals acquired with wearable devices or from publicly available databases and the analysis of such signals with artificial intelligence methods to detect and predict diseases. As expected, most of the available research focuses on heart diseases, sleep apnea, and other emerging areas, such as mental stress. From a methodological point of view, although traditional statistical methods and machine learning are still widely used, we observe an increasing use of more advanced deep learning methods, specifically architectures that can handle the complexity of biosignal data. These deep learning methods typically include convolutional and recurrent neural networks. Moreover, when proposing new artificial intelligence methods, we observe that the prevalent choice is to use publicly available databases rather than collecting new data.

2 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Luca NeriLuca Neri
Luca Neri
MOMatt T. Oberdier
Matt T. Oberdier
AAAntonio Augello
Antonio Augello
MSMasahito Suzuki
Masahito Suzuki
ETEthan Tumarkin
Ethan Tumarkin
Claudio  BorghiClaudio Borghi
Claudio Borghi
Recent advancements in smart, wearable technologies have allowed the detection of various medical conditions. In particular, continuous collection and real-time analysis of electrocardiogram data have enabled the early identification of pathologic cardiac rhythms. Various algorithms to assess cardiac rhythms have been developed, but these utilize excessive computational power. Therefore, adoption to mobile platforms requires more computationally efficient algorithms that do not sacrifice correctness. This study presents a modified QRS detection algorithm, the AccYouRate Modified Pan–Tompkins (AMPT), which is a simplified version of the well-established Pan–Tompkins algorithm. Using archived ECG data from a variety of publicly available datasets, relative to the Pan–Tompkins, the AMPT algorithm demonstrated improved computational efficiency by 5–20×, while also universally enhancing correctness, both of which favor translation to a mobile platform for continuous, real-time QRS detection.

27 May 2024 in Journal of Medical Systems
Verified
Journal Article
Open access
PDF file
Luca NeriLuca Neri
Luca Neri
ICIvan Corazza
Ivan Corazza
MOMatt T. Oberdier
Matt T. Oberdier
JLJessica Lago
Jessica Lago
IGIlaria Gallelli
Ilaria Gallelli
Claudio  BorghiClaudio Borghi
Claudio Borghi
Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20–82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as “Good”, 12% as “Acceptable”, and 18% as “Not Readable”. The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.

30 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AOAlessandro Orro
Alessandro Orro
GGGian Angelo Geminiani
Gian Angelo Geminiani
FSFrancesco Sicurello
Francesco Sicurello
MMMarcello Modica
Marcello Modica
Francesco PegreffiFrancesco Pegreffi
Francesco Pegreffi
MBMatteo Botteghi
Matteo Botteghi
Wearable devices have a significant impact on society, and recent advancements in modern sensor technologies are opening up new possibilities for healthcare applications. Continuous vital sign monitoring using Internet of Things solutions can be a crucial tool for emergency management, reducing risks in rescue operations and ensuring the safety of workers. The massive amounts of data, high network traffic, and computational demands of a typical monitoring application can be challenging to manage with traditional infrastructure. Cloud computing provides a solution with its built-in resilience and elasticity capabilities. This study presents a Cloud-based monitoring architecture for remote vital sign tracking of paramedics and medical workers through the use of a mobile wearable device. The system monitors vital signs such as electrocardiograms and breathing patterns during work sessions, and it is able to manage real-time alarm events to a personnel management center. In this study, 900 paramedics and emergency workers were monitored using wearable devices over a period of 12 months. Data from these devices were collected, processed via Cloud infrastructure, and analyzed to assess the system’s reliability and scalability. The results showed a significant improvement in worker safety and operational efficiency. This study demonstrates the potential of Cloud-based systems and Internet of Things devices in enhancing emergency response efforts.

25 February 2025 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
MOMatt T Oberdier
Matt T Oberdier
Luca NeriLuca Neri
Luca Neri
AOAlessandro Orro
Alessandro Orro
RCRichard T Carrick
Richard T Carrick
MNMarco S Nobile
Marco S Nobile
HHHenry R Halperin
Henry R Halperin
Aims: Sudden cardiac arrest (SCA) is a commonly fatal event that often occurs without prior indications. To improve outcomes and enable preventative strategies, the electrocardiogram (ECG) in conjunction with deep learning was explored as a potential screening tool. Methods and results: A publicly available data set containing 10 s of 12-lead ECGs from individuals who did and did not have an SCA, information about time from ECG to arrest, and age and sex was utilized for analysis to individually predict SCA or not using deep convolution neural network models. The base model that included age and sex, ECGs within 1 day prior to arrest, and data sampled from windows of 720 ms around the R-waves from 221 individuals with SCA and 1046 controls had an area under the receiver operating characteristic curve of 0.77. With sensitivity set at 95%, base model specificity was 31%, which is not clinically applicable. Gradient-weighted class activation mapping showed that the model mostly relied on the QRS complex to make predictions. However, models with ECGs recorded between 1 day to 1 month and 1 month to 1 year prior to arrest demonstrated predictive capabilities. Conclusion: Deep learning models processing ECG data are a promising means of screening for SCA, and this method explains differences in SCAs due to age and sex. Model performance improved when ECGs were nearer in time to SCAs, although ECG data up to a year prior had predictive value. Sudden cardiac arrest prediction was more dependent upon QRS complex data compared to other ECG segments.