Stefano Rossi

Dr. Stefano Rossi

Department of Economics, Engineering, Society and Business Organization (DEIM) – University of Tuscia, Viterbo, Italy
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Juri TaborriJuri Taborri
Juri Taborri
Eduardo PalermoEduardo Palermo
Eduardo Palermo
Stefano RossiStefano Rossi
Stefano Rossi
PCPaolo Cappa
Paolo Cappa
In the last years, gait phase partitioning has come to be a challenging research topic due to its impact on several applications related to gait technologies. A variety of sensors can be used to feed algorithms for gait phase partitioning, mainly classifiable as wearable or non-wearable. Among wearable sensors, footswitches or foot pressure insoles are generally considered as the gold standard; however, to overcome some inherent limitations of the former, inertial measurement units have become popular in recent decades. Valuable results have been achieved also though electromyography, electroneurography, and ultrasonic sensors. Non-wearable sensors, such as opto-electronic systems along with force platforms, remain the most accurate system to perform gait analysis in an indoor environment. In the present paper we identify, select, and categorize the available methodologies for gait phase detection, analyzing advantages and disadvantages of each solution. Finally, we comparatively examine the obtainable gait phase granularities, the usable computational methodologies and the optimal sensor placements on the targeted body segments.

1 June 2014 in Measurement
Verified
Journal Article
Closed access
Eduardo PalermoEduardo Palermo
Eduardo Palermo
Stefano RossiStefano Rossi
Stefano Rossi
FMFrancesca Marini
Francesca Marini
FPFabrizio Patane
Fabrizio Patane
PCPaolo Cappa
Paolo Cappa

2 September 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Juri TaborriJuri Taborri
Juri Taborri
Stefano RossiStefano Rossi
Stefano Rossi
Eduardo PalermoEduardo Palermo
Eduardo Palermo
FPFabrizio Patane
Fabrizio Patane
PCPaolo Cappa
Paolo Cappa
In this work, we decided to apply a hierarchical weighted decision, proposed and used in other research fields, for the recognition of gait phases. The developed and validated novel distributed classifier is based on hierarchical weighted decision from outputs of scalar Hidden Markov Models (HMM) applied to angular velocities of foot, shank, and thigh. The angular velocities of ten healthy subjects were acquired via three uni-axial gyroscopes embedded in inertial measurement units (IMUs) during one walking task, repeated three times, on a treadmill. After validating the novel distributed classifier and scalar and vectorial classifiers-already proposed in the literature, with a cross-validation, classifiers were compared for sensitivity, specificity, and computational load for all combinations of the three targeted anatomical segments. Moreover, the performance of the novel distributed classifier in the estimation of gait variability in terms of mean time and coefficient of variation was evaluated. The highest values of specificity and sensitivity (>0.98) for the three classifiers examined here were obtained when the angular velocity of the foot was processed. Distributed and vectorial classifiers reached acceptable values (>0.95) when the angular velocity of shank and thigh were analyzed. Distributed and scalar classifiers showed values of computational load about 100 times lower than the one obtained with the vectorial classifier. In addition, distributed classifiers showed an excellent reliability for the evaluation of mean time and a good/excellent reliability for the coefficient of variation. In conclusion, due to the better performance and the small value of computational load, the here proposed novel distributed classifier can be implemented in the real-time application of gait phases recognition, such as to evaluate gait variability in patients or to control active orthoses for the recovery of mobility of lower limb joints.

1 April 2018 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
Juri TaborriJuri Taborri
Juri Taborri
Valentina AgostiniValentina Agostini
Valentina Agostini
PAPanagiotis Artemiadis
Panagiotis Artemiadis
MGMarco GHISLIERI
Marco GHISLIERI
DJDaniel A. Jacobs
Daniel A. Jacobs
Stefano RossiStefano Rossi
Stefano Rossi
In the last years, several studies have been focused on understanding how the central nervous system controls muscles to perform a specific motor task. Although it still remains an open question, muscle synergies have come to be an appealing theory to explain the modular organization of the central nervous system. Even though the neural encoding of muscle synergies remains controversial, a large number of papers demonstrated that muscle synergies are robust across different tested conditions, which are within a day, between days, within a single subject, and between subjects that have similar demographic characteristics. Thus, muscle synergy theory has been largely used in several research fields, such as clinics, robotics, and sports. The present systematical review aims at providing an overview on the applications of muscle synergy theory in clinics, robotics, and sports; in particular, the review is focused on the papers that provide tangible information for (i) diagnosis or pathology assessment in clinics, (ii) robot-control design in robotics, and (iii) athletes’ performance assessment or training guidelines in sports.

6 March 2015 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
KMKonstantinos P. Michmizos
Konstantinos P. Michmizos
Stefano RossiStefano Rossi
Stefano Rossi
ECEnrico Castelli
Enrico Castelli
PCPaolo Cappa
Paolo Cappa
HKHermano Igo Krebs
Hermano Igo Krebs
This paper presents the pediAnklebot, an impedance-controlled low-friction, backdriveable robotic device developed at the Massachusetts Institute of Technology that trains the ankle of neurologically impaired children of ages 6-10 years old. The design attempts to overcome the known limitations of the lower extremity robotics and the unknown difficulties of what constitutes an appropriate therapeutic interaction with children. The robot's pilot clinical evaluation is on-going and it incorporates our recent findings on the ankle sensorimotor control in neurologically intact subjects, namely the speed-accuracy tradeoff, the deviation from an ideally smooth ankle trajectory, and the reaction time. We used these concepts to develop the kinematic and kinetic performance metrics that guided the ankle therapy in a similar fashion that we have done for our upper extremity devices. Here we report on the use of the device in at least nine training sessions for three neurologically impaired children. Results demonstrated a statistically significant improvement in the performance metrics assessing explicit and implicit motor learning. Based on these initial results, we are confident that the device will become an effective tool that harnesses plasticity to guide habilitation during childhood.

30 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Juri TaborriJuri Taborri
Juri Taborri
Luca MolinaroLuca Molinaro
Luca Molinaro
ASAdriano Santospagnuolo
Adriano Santospagnuolo
VMVetrano Mario
Vetrano Mario
MVMaria Chiara Vulpiani
Maria Chiara Vulpiani
Stefano RossiStefano Rossi
Stefano Rossi
Anterior cruciate ligament (ACL) injury represents one of the main disorders affecting players, especially in contact sports. Even though several approaches based on artificial intelligence have been developed to allow the quantification of ACL injury risk, their applicability in training sessions compared with the clinical scale is still an open question. We proposed a machine-learning approach to accomplish this purpose. Thirty-nine female basketball players were enrolled in the study. Leg stability, leg mobility and capability to absorb the load after jump were evaluated through inertial sensors and optoelectronic bars. The risk level of athletes was computed by the Landing Error Score System (LESS). A comparative analysis among nine classifiers was performed by assessing the accuracy, F1-score and goodness. Five out nine examined classifiers reached optimum performance, with the linear support vector machine achieving an accuracy and F1-score of 96 and 95%, respectively. The feature importance was computed, allowing us to promote the ellipse area, parameters related to the load absorption and the leg mobility as the most useful features for the prediction of anterior cruciate ligament injury risk. In addition, the ellipse area showed a strong correlation with the LESS score. The results open the possibility to use such a methodology for predicting ACL injury.