Marco GHISLIERI

Dr. Marco GHISLIERI

Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Piedmont, Italy
orcid
Assistant Professor with time contract

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MGMarco GHISLIERI
Marco GHISLIERI
LGLaura Gastaldi
Laura Gastaldi
SPStefano Pastorelli
Stefano Pastorelli
STShigeru Tadano
Shigeru Tadano
Valentina AgostiniValentina Agostini
Valentina Agostini
Wearable sensors are de facto revolutionizing the assessment of standing balance. The aim of this work is to review the state-of-the-art literature that adopts this new posturographic paradigm, i.e., to analyse human postural sway through inertial sensors directly worn on the subject body. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 73 full-text articles, selecting 47 high-quality contributions. A good inter-rater reliability was obtained (Cohen’s kappa = 0.79). This selection of papers was used to summarize the available knowledge on the types of sensors used and their positioning, the data acquisition protocols and the main applications in this field (e.g., “active aging”, biofeedback-based rehabilitation for fall prevention, and the management of Parkinson’s disease and other balance-related pathologies), as well as the most adopted outcome measures. A critical discussion on the validation of wearable systems against gold standards is also presented.

1 April 2018 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
Juri TaborriJuri Taborri
Juri Taborri
Valentina AgostiniValentina Agostini
Valentina Agostini
PAPanagiotis Artemiadis
Panagiotis Artemiadis
MGMarco GHISLIERI
Marco GHISLIERI
DJDaniel A. Jacobs
Daniel A. Jacobs
Stefano RossiStefano Rossi
Stefano Rossi
In the last years, several studies have been focused on understanding how the central nervous system controls muscles to perform a specific motor task. Although it still remains an open question, muscle synergies have come to be an appealing theory to explain the modular organization of the central nervous system. Even though the neural encoding of muscle synergies remains controversial, a large number of papers demonstrated that muscle synergies are robust across different tested conditions, which are within a day, between days, within a single subject, and between subjects that have similar demographic characteristics. Thus, muscle synergy theory has been largely used in several research fields, such as clinics, robotics, and sports. The present systematical review aims at providing an overview on the applications of muscle synergy theory in clinics, robotics, and sports; in particular, the review is focused on the papers that provide tangible information for (i) diagnosis or pathology assessment in clinics, (ii) robot-control design in robotics, and (iii) athletes’ performance assessment or training guidelines in sports.

1 October 2021 in Gait & Posture
Verified
Journal Article
Closed access
Luciana LabancaLuciana Labanca
Luciana Labanca
MMMassimiliano Mosca
Massimiliano Mosca
MGMarco GHISLIERI
Marco GHISLIERI
Valentina AgostiniValentina Agostini
Valentina Agostini
MKMarco KNAFLITZ
Marco KNAFLITZ
MBMaria Grazia Benedetti
Maria Grazia Benedetti

21 October 2021 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MGMarco GHISLIERI
Marco GHISLIERI
GCGiacinto Luigi Cerone
Giacinto Luigi Cerone
MKMarco Knaflitz
Marco Knaflitz
Valentina AgostiniValentina Agostini
Valentina Agostini
Background: The accurate temporal analysis of muscle activation is of great interest in many research areas, spanning from neurorobotic systems to the assessment of altered locomotion patterns in orthopedic and neurological patients and the monitoring of their motor rehabilitation. The performance of the existing muscle activity detectors is strongly affected by both the SNR of the surface electromyography (sEMG) signals and the set of features used to detect the activation intervals. This work aims at introducing and validating a powerful approach to detect muscle activation intervals from sEMG signals, based on long short-term memory (LSTM) recurrent neural networks.Methods: First, the applicability of the proposed LSTM-based muscle activity detector (LSTM-MAD) is studied through simulated sEMG signals, comparing the LSTM-MAD performance against other two widely used approaches, i.e., the standard approach based on Teager–Kaiser Energy Operator (TKEO) and the traditional approach, used in clinical gait analysis, based on a double-threshold statistical detector (Stat). Second, the effect of the Signal-to-Noise Ratio (SNR) on the performance of the LSTM-MAD is assessed considering simulated signals with nine different SNR values. Finally, the newly introduced approach is validated on real sEMG signals, acquired during both physiological and pathological gait. Electromyography recordings from a total of 20 subjects (8 healthy individuals, 6 orthopedic patients, and 6 neurological patients) were included in the analysis.Results: The proposed algorithm overcomes the main limitations of the other tested approaches and it works directly on sEMG signals, without the need for background-noise and SNR estimation (as in Stat). Results demonstrate that LSTM-MAD outperforms the other approaches, revealing higher values of F1-score (F1-score > 0.91) and Jaccard similarity index (Jaccard > 0.85), and lower values of onset/offset bias (average absolute bias < 6 ms), both on simulated and real sEMG signals. Moreover, the advantages of using the LSTM-MAD algorithm are particularly evident for signals featuring a low to medium SNR.Conclusions: The presented approach LSTM-MAD revealed excellent performances against TKEO and Stat. The validation carried out both on simulated and real signals, considering normal as well as pathological motor function during locomotion, demonstrated that it can be considered a powerful tool in the accurate and effective recognition/distinction of muscle activity from background noise in sEMG signals.

9 January 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MGMarco GHISLIERI
Marco GHISLIERI
Valentina AgostiniValentina Agostini
Valentina Agostini
MKMarco Knaflitz
Marco Knaflitz
The muscle synergy theory has been widely used to assess the modular organization of the central nervous system (CNS) during human locomotion. The pre-processing approach applied to the surface electromyographic (sEMG) signals influences the extraction of muscle synergies. The aim of this contribution is to assess the improvements in muscle synergy extraction obtained by using an innovative pre-processing approach. We evaluate the improvement in terms of the possible variation in the number of muscle synergies, of the intra-subject consistency, of the robustness, and of the interpretability of the results. The pre-processing approach presented in this paper is based on the extraction of the muscle principal activations (muscle activations strictly necessary to accomplish a specific biomechanical task) from the original sEMG signals, to then obtain muscle synergies using principal activations only. The results herein presented show that the application of this novel approach for the extraction of the muscle synergies provides a more robust and easily interpretable description of the modular organization of the CNS with respect to the standard preprocessing approach.

4 January 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
GCGiacinto Luigi Cerone
Giacinto Luigi Cerone
AGA. Giangrande
A. Giangrande
MGMarco GHISLIERI
Marco GHISLIERI
MGMARCO GAZZONI
MARCO GAZZONI
HPHarri Piitulainen
Harri Piitulainen
ABAlberto Botter
Alberto Botter
Sensorimotor integration is the process through which the human brain plans the motor program execution according to external sources. Within this context, corticomuscular and corticokinematic coherence analyses are common methods to investigate the mechanism underlying the central control of muscle activation. This requires the synchronous acquisition of several physiological signals, including EEG and sEMG. Nevertheless, physical constraints of the current, mostly wired, technologies limit their application in dynamic and naturalistic contexts. In fact, although many efforts were made in the development of biomedical instrumentation for EEG and High Density-surface EMG (HD-sEMG) signal acquisition, the need for an integrated wireless system is emerging. We hereby describe the design and validation of a new fully wireless body sensor network for the integrated acquisition of EEG and HD-sEMG signals. This Body Sensor Network is composed of wireless bio-signal acquisition modules, named sensor units, and a set of synchronization modules used as a general-purpose system for time-locked recordings. The system was characterized in terms of accuracy of the synchronization and quality of the collected signals. An in-depth characterization of the entire system and an head-to-head comparison of the wireless EEG sensor unit with a wired benchmark EEG device were performed. The proposed device represents an advancement of the State-of-the-Art technology allowing the integrated acquisition of EEG and HD-sEMG signals for the study of sensorimotor integration.