zhonghan wang

Dr. zhonghan wang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2018 in IEEE Access
Verified
Journal Article
Open access
ZWzhonghan wang
zhonghan wang
YSYaoliang Song
Yaoliang Song
TMTong Mu
Tong Mu
ZAZeeshan Ahmad
Zeeshan Ahmad
In this paper, we propose a new technique to generate a range-angle dependent transmit beampattern by introducing a nonlinear frequency modulation scheme based on arctangent function in the frequency diverse array (FDA) system. The propagation process of the transmitted signals is usually neglected in most of the existing range-angle dependent transmit beampattern synthesis schemes. More specifically, the time variable is considered to be a constant value or defined from 0 to T, where Tis the pulse duration for pulsed FDA. As a result, such schemes cease to focus the signal power at a desired position for a period of time when this practical constraint is taken into account. The proposed methodology incorporates the propagation process of the transmitted signal and simultaneously focuses the signal power at a desired position and lasting for a period of time. We investigate the consequences of this constraint briefly and also explain the corrected model. Numerical simulations are implemented to validate the theoretical analysis of the proposed methodology.

5 March 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ZWzhonghan wang
zhonghan wang
YSYaoliang Song
Yaoliang Song
YLYitong Li
Yitong Li
Imaging systems based on millimeter waves (mm-waves) are advancing to achieve higher resolution and wider bandwidth. However, a large bandwidth requires high sample rates, which may limit the development of ultra-wideband imaging systems. In this letter, we introduce the concept of frequency diverse array (FDA) into mm-wave imaging systems. In particular, we propose an ultra-wideband imaging method based on the FDA configuration to reduce sampling rates. In the proposed method, the required sampling rate of an imaging system with N transmit elements is only one-Nth of the conventional systems. Hence, the proposed method can significantly reduce the sampling rate. Unlike compressed-sensing-based sampling methods, the proposed method does not require repeated observations, and is easier to implement. Thanks to the FDA concept, the proposed method can scan the space without phase-shifters or rotation of antennas. We perform matched filtering process in the frequency domain to obtain frequency-delay-dependent vectors. By discretizing the scene, we establish a dictionary covering the imaging scene. Accordingly, a convex optimization problem with measured results and the dictionary based on sparse reconstruction are formulated to realize super-resolution imaging. Compared to conventional methods, the proposed method can distinguish smaller target intervals with low sampling rate in an easy-to-implement way. The proposed method provides a different perspective for the development of ultra-wideband imaging systems.

21 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
ZAZeeshan Ahmad
Zeeshan Ahmad
ZWzhonghan wang
zhonghan wang
ZJZain ul Abidin Jaffri
Zain ul Abidin Jaffri
SBShudi Bao
Shudi Bao
Wireless power transfer (WPT) is a well-known problem, and has received wide attention in the next generation industrial applications and consumer electronics. On the other hand, frequency diverse array (FDA) is a new concept with the ability to generate a range-angle dependent beampattern. Therefore, some researchers are engaged in designing WPT systems based on the FDA framework (FDA-WPT) instead of phased arrays. Unlike phased arrays, the FDA beampattern is time-variant. Therefore, existing beam collection efficiency models based on the phased array are not suitable for the FDA-WPT system. More importantly, the time-variant property of FDAs is usually ignored in the literature, and the system configuration of the target area where the power-harvesting end is located does not conform to the actual WPT scenario. In this paper, we derive and present accurate models of the FDA-WPT system. The power transfer performance of the corrected FDA-WPT system is then compared with the phased array based WPT system. Simulation results demonstrate that time-variant consideration in the FDA-WPT model causes difficulty in controlling the main beam direction to focus the power. The accurate FDA-WPT is theoretically investigated, and numerical simulations are implemented to validate the theoretical analysis.

1 September 2018 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
Verified
Journal Article
Open access
PDF file
TMTong Mu
Tong Mu
YSYaoliang Song
Yaoliang Song
ZWzhonghan wang
zhonghan wang
The basic frequency diverse array (FDA) using linearly increasing frequency increments generates a range-angle dependent beampattern. However, it is coupled in range and angle dimensions and is also periodic in range and time, making its applications limited. In this paper, a novel FDA beampattern synthesis approach is proposed utilizing the time-modulated double parameters based on the chaos sequence. The chirp signal mechanism is used instead of the single-frequency signal mechanism. Meanwhile, the multi-carrier architecture is used for range-angle decoupling. Satisfactory time-invariant range-angle beampattern can be synthesized for both single and multiple targets locations. Simulation results show the effectiveness of the proposed FDA scheme. Furthermore, comparative study with the existing technology indicates that the proposed approach can provide better performance in spatial focusing and side-lobe suppressing.

17 March 2021 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
ZWzhonghan wang
zhonghan wang
YSYaoliang Song
Yaoliang Song
SFshicheng fan
shicheng fan
YFYuan Fan
Yuan Fan
With the ability to increase the gain of the millimeter-wave antenna system effectively, lenses have attracted wide attention. Researchers proposed a large number of lens-based array systems. When each array element works alone, the system can transmit beams in different directions. However, it is difficult to adjust the scanning angle flexibly. In this letter, we propose a method to synthesize the radiation pattern of the lens-array system, which can flexibly adjust the scanning angle by weighted array elements. Firstly, we derive an approximate mathematical model of the lens-array system. Then, the influence of the weighting coefficients on the far-field radiation pattern of the system is analyzed. By setting coefficients as the optimization parameters and combining it with the desired beampattern, we establish an optimization model. Then we optimize the coefficients. Full-wave simulation results performed by CST studio and measured results demonstrate that the proposed method can approach the desired radiation pattern by the optimized coefficients. What's more, measured results show that the proposed method is suitable for wideband signals. Hence, the presented method can flexibly adjust the scanning angle.

11 February 2021 in International Journal of Microwave and Wireless Technologies
Verified
Journal Article
Closed access
PDF file
ZWzhonghan wang
zhonghan wang
YSYaoliang Song
Yaoliang Song
A frequency diverse array (FDA) radar has attracted wide attention, due to its capability to provide a range-angle dependent beampattern and to scan the spatial without phase shifters or rotating arrays. However, FDA systems will suffer from low echo signal energy or high sidelobe peaks when detecting targets by beamforming based on existing receivers. To reduce the sidelobe peak of detection results while increasing the echo signal energy, in this paper, we propose an FDA radar system based on diversity linear frequency modulation waveforms. Correspondingly, we propose a receiver architecture with a time-variant beamforming chain. The proposed system retains the ability of the FDA system to automatically spatial beam scanning, owing to the frequency increment across elements. By increasing the pulse duration of transmitted signals, we enhance the echo signal energy. By applying the artificial bee colony algorithm to design the bandwidth of each chirp signal, the proposed system reduces the sidelobe level of detection results while increasing pulse width. Numerical simulation results are presented to demonstrate the effectiveness of the proposed system.