In view of scarcity of traditional energy resources and environmental issues, renewable energy resources (RERs) are introduced to fulfill the electricity requirement of growing world. Moreover, the effective utilization of RERs to fulfill the varying electricity demands of customers can be achieved via demand response (DR). Furthermore, control techniques, decision variables and offered motivations are the ways to introduce DR into distribution network (DN). This categorization needs to be optimized to balance the supply and demand in DN. Therefore, intelligent algorithms are employed to achieve optimized DR. However, these algorithms are computationally restrained to handle the parametric load of uncertainty involved with RERs and power system. Henceforth, this paper focuses on the limitations of intelligent algorithms for DR. Furthermore, a comparative study of different intelligent algorithms for DR is discussed. Based on conclusions, quantum algorithms are recommended to optimize the computational burden for DR in future smart grid.
The green innovations in the energy sector are smart solutions to meet the excessive power requirements through renewable energy resources (RERs). These resources have forwarded the revolutionary relief in control of carbon dioxide gaseous emissions from traditional energy resources. The use of RERs in a heuristic manner is necessary to meet the demand side management in microgrids (MGs). The pricing scheme limitations hinder the profit maximization of MG and their customers. In addition, recent pricing schemes lack mechanistic underpinning. Therefore, a dynamic electricity pricing scheme through linear regression is designed for RERs to maximize the profit of load customers (changeable and unchangeable) in MG. The demand response optimization problem is solved through the particle swarm optimization (PSO) technique. The proposed dynamic electricity pricing scheme is evaluated under two different scenarios. The simulation results verified that the proposed dynamic electricity pricing scheme sustained the profit margins and comforts for changeable and unchangeable load customers as compared to fixed electricity pricing schemes in both scenarios. Hence, the proposed dynamic electricity pricing scheme can readily be used for real microgrids (MGs) to grasp the goal for cleaner energy production.
The design and implementation of energy-efficient routing protocols for next-generation wireless sensor networks is always a challenge due to limited power resource capabilities. Hierarchical (clustering) routing protocols appeared to be a remarkable solution for extending the lifetime of wireless sensor networks, particularly in application-aware (threshold-sensitive) and heterogeneity-aware cluster-based routing protocols. In this article, we propose a protocol, namely, Threshold-based Energy-aware Zonal Efficiency Measuring hierarchical routing protocol. It is a heterogeneity-aware and threshold-based protocol that provides a better solution to existing problems in next-generation wireless sensor networks. During execution, the Threshold-based Energy-aware Zonal Efficiency Measuring hierarchical routing protocol splits the entire network area into several zones to manage network traffic efficiently. In the first step, Threshold-based Energy-aware Zonal Efficiency Measuring hierarchical routing protocol is designed for a homogeneous network where the initial energy of all the nodes is the same. Thereafter, we bring in heterogeneity in the Threshold-based Energy-aware Zonal Efficiency Measuring hierarchical routing protocol execution environment to optimize its energy consumption. By investigating the performance of the various numbers of divisions, it is proved that the Threshold-based Energy-aware Zonal Efficiency Measuring hierarchical routing protocol with 9 zonal divisions has higher stability and throughput. The performance of the proposed Threshold-based Energy-aware Zonal Efficiency Measuring hierarchical routing protocol is compared with those of Stable Election Protocol, Low-Energy Adaptive Clustering Hierarchy, Modified Low-Energy Adaptive Clustering Hierarchy, and Gateway-Based Energy-Efficient Routing Protocol through computer simulations. Simulation results verify the improved performance of the proposed Threshold-based Energy-aware Zonal Efficiency Measuring hierarchical routing protocol in terms of network stability, lifetime, and throughput.
A voltage stability index is proposed using a new single-port equivalent depending on component peculiarity representation and sensitivity persistence to locate and determine long-term voltage instability in transmission and distribution power networks. The suggested single-port equivalent effectively represents the equivalence of various component types and assures the consistency of sensitivity information before and after the equivalence which is compulsory for the equivalent accuracy in estimating the voltage stability analysis. The stability index is derived from the new single-port equivalent to determine the system voltage instability. The proposed stability index is compared with indices based on virtual impedance and Thevenin impedance models. This new stability index shows more accuracy and effectiveness as compared to the indices based on virtual and Thevenin equivalent models. The index also determines the weak buses, where an improvement or functional measure can be used to reduce the system voltage instability. The validity of the proposed equivalent approach and stability index is presented by utilizing two radial systems, four IEEE systems and an actual system having bus size from five to 1010 buses.