Alaaldeen Al-Halhouli

Dr. Alaaldeen Al-Halhouli


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2015 in Micromachines
Verified
Journal Article
Open access
PDF file
AAAlaaldeen Al-Halhouli
Alaaldeen Al-Halhouli
AAAiman Alshare
Aiman Alshare
MMMukeet Mohsen
Mukeet Mohsen
MMMaher Matar
Maher Matar
Andreas DietzelAndreas Dietzel
Andreas Dietzel
SBStephanus Büttgenbach
Stephanus Büttgenbach
This study presents experiments and computational simulations of single-layer passive micromixer designs. The proposed designs consist of chains of interlocking semicircles and omega-shaped mixing modules. The performance of the new designs is compared with the concentric spiral channel configuration. The micromixers are intended to be integrated into a lab on chip (LOC) micro-system that operates under continuous flow conditions. The purpose behind the multi-curvature in these designs is the introduction of Dean vortices in addition to molecular diffusion in order to enhance the mixing performance. The micromixers were fabricated in PDMS (Polydimethylsiloxane) and bonded to a glass substrate. A three-dimensional computational model of micromixers was carried out using Fluent ANSYS. In experiments, the mixing of a 1 g/L fluorescein isothiocyanate diluted in distilled water was observed and photographed using a charge-coupled device (CCD) microscopic camera. The obtained images were processed to determine the mixing intensity at different Reynolds numbers. The standard deviation (σ) of the fluorescence indicates the mixing completeness, which was calculated along the width of the channel at various locations downstream from the channel inlet. The value of σ = 0.5 indicates unmixed streams and 0 is for complete mixing. It is found that the two new designs have a standard deviation of nearly 0.05. Additionally, complete mixing was observed at the channel outlet as demonstrated by the fluorescence images and the numerical results. However, the location of complete mixing at different positions depends on the Reynolds number, which varies between 0.01 and 50. Good agreement was found between the experiment and the numerical results. A correlation to predict the length scale where complete mixing can be achieved is given in terms of the radius of curvature, the mixing module, and the Reynolds number.

18 July 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
AAAlaaldeen Al-Halhouli
Alaaldeen Al-Halhouli
SDStefanie Demming
Stefanie Demming
AWAndreas Waldschik
Andreas Waldschik
SBStephanus Büttgenbach
Stephanus Büttgenbach
This paper introduces the synchronous micromotor concept and presents new investigations on its application as an integrated driving mechanism in microfluidic systems. A spiral channel viscous micropump and a microstirrer are considered and tested as examples to verify the concept. The fabrication technology of such integrated systems is based on UV depth lithography, electroplating and soft lithography. The synchronous micromotor consists of a stator including double layer coils, and a rotor disk containing alternate permanent magnets. The coils are distributed evenly around the stator and arranged in three phases. The phases are excited by sinusoidal currents with a corresponding phase shift resulting in a rotating magnetic field. Regarding the spiral channel viscous micropump, a spiral disk was fixed onto the rotor disk and run at different rotational speeds. Tests showed very promising results, with a flow rate up to 1023 µL·min−1 at a motor rotational speed of 4500 rpm. Furthermore, for the application of a microstirred-tank bioreactor, the rotor disk design was modified to work as a stirrer. The performance of the developed microbioreactor was tested over a time period of approximately 10 h under constant stirring. Tests demonstrated the successful cultivation of S. cerevisiae through the integration of the microstirrer in a microbioreactor system. These systems prove that synchronous micromotors are well suited to serve as integrated driving mechanisms of active microfluidic components.

4 December 2015 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
AAAlaaldeen Al-Halhouli
Alaaldeen Al-Halhouli
SDStefanie Demming
Stefanie Demming
Andreas DietzelAndreas Dietzel
Andreas Dietzel
SBStephanus Büttgenbach
Stephanus Büttgenbach
This paper presents the design, fabrication, and characterization of a continuous flow micropump system. The system comprises two single pneumatic micropumps connected in parallel and a fluidic capacitor. It has been made of polydimethylsiloxane (PDMS). Each of the pneumatic pumps features a pump chamber, a flexible membrane, and an air chamber. The fluidic capacitor equals a single micropump without air chamber. A maximum flow rate of 496 μL/min is obtained. The influence of the fluidic capacitor is investigated at frequencies of 1 Hz and 3 Hz. The flow rate is considerably smoothened with a smoothing factor of about 0.6.

25 August 2014 in Sensors
Verified
Journal Article
Open access
PDF file
AAAlaaldeen Al-Halhouli
Alaaldeen Al-Halhouli
SDStefanie Demming
Stefanie Demming
LALaila Alahmad
Laila Alahmad
ALAndreu Liobera
Andreu Liobera
SBStephanus Büttgenbach
Stephanus Büttgenbach
This paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor design allows optical detection of glucose concentrations under continuous glucose flow conditions of 33 µL/h based on internal co-immobilization of glucose oxidase (GOX) and horseradish peroxidase (HRP) on the internal PDMS surface of the reactor chamber. For this design, two co-immobilization methods, the simple adsorption and the covalent binding (PEG) methods were tested. Experiments showed successful results when using the covalent binding (PEG) method, where glucose concentrations up to 5 mM with a coefficient of determination (R2) of 0.99 and a limit of detection of 0.26 mM are detectable. The second design is a modified version of the internally immobilized sensor, where a microbead chamber and a beads filling channel are integrated into the sensor. This modification enabled external co-immobilization of enzymes covalently onto functionalized silica microbeads and allows binding a huge amount of HRP and GOX enzymes on the microbeads surfaces which increases the interaction area between immobilized enzymes and the analyte. This has a positive effect on the amount and rate of chemical reactions taking place inside the chamber. The sensor was tested under continuous glucose flow conditions and was found to be able to detect glucose concentrations up to 10 mM with R2 of 0.98 and a limit of detection of 0.7 mM. Such results are very promising for the application in photonic LOC systems used for online analysis.