Microactuators have become essential elements of microelectromechanical systems, for example, for positioning purposes and for fluid-handling tasks in microfluidic systems. UV depth lithography and other new micromachining technologies, which have been developed since the 1990s, have initiated extensive investigations of electromagnetic microactuators, which are characterized by high forces, large deflections, low driving voltages resulting from low input impedances and robustness under harsh environments. This paper reviews the comprehensive research on the design, fabrication and application of electromagnetic micromotors performed in our laboratory over the past years.
This work presents a multiparametric system capable of characterizing and classifying white wines according to the grape variety and geographical origin. Besides, it quantifies specific parameters of interest for quality control in wine. The system, known as a hybrid electronic tongue, consists of an array of electrochemical microsensors—six ISFET based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, a gold microelectrode and a microelectrode for sensing electrochemical oxygen demand—and a miniaturized optofluidic system. The test sample set comprised eighteen Catalan monovarietal white wines from four different grape varieties, two Croatian monovarietal white wines and seven bi- and trivarietal mixtures prepared from the Catalan varieties. Different chemometric tools were used to characterize (i.e., Principal Component Analysis), classify (i.e., Soft Independent Modeling Class Analogy) and quantify (i.e., Partial-Least Squares) some parameters of interest. The results demonstrate the usefulness of the multisensor system for analysis of wine.
This study presents experiments and computational simulations of single-layer passive micromixer designs. The proposed designs consist of chains of interlocking semicircles and omega-shaped mixing modules. The performance of the new designs is compared with the concentric spiral channel configuration. The micromixers are intended to be integrated into a lab on chip (LOC) micro-system that operates under continuous flow conditions. The purpose behind the multi-curvature in these designs is the introduction of Dean vortices in addition to molecular diffusion in order to enhance the mixing performance. The micromixers were fabricated in PDMS (Polydimethylsiloxane) and bonded to a glass substrate. A three-dimensional computational model of micromixers was carried out using Fluent ANSYS. In experiments, the mixing of a 1 g/L fluorescein isothiocyanate diluted in distilled water was observed and photographed using a charge-coupled device (CCD) microscopic camera. The obtained images were processed to determine the mixing intensity at different Reynolds numbers. The standard deviation (σ) of the fluorescence indicates the mixing completeness, which was calculated along the width of the channel at various locations downstream from the channel inlet. The value of σ = 0.5 indicates unmixed streams and 0 is for complete mixing. It is found that the two new designs have a standard deviation of nearly 0.05. Additionally, complete mixing was observed at the channel outlet as demonstrated by the fluorescence images and the numerical results. However, the location of complete mixing at different positions depends on the Reynolds number, which varies between 0.01 and 50. Good agreement was found between the experiment and the numerical results. A correlation to predict the length scale where complete mixing can be achieved is given in terms of the radius of curvature, the mixing module, and the Reynolds number.
In this contribution, we report on different miniaturized bulk micro machined three-axes piezoresistive force sensors for nanopositioning and nanomeasuring machine (NPMM). Various boss membrane structures, such as one boss full/cross, five boss full/cross and swastika membranes, were used as a basic structure for the force sensors. All designs have 16 p-type diffused piezoresistors on the surface of the membrane. Sensitivities in x, y and z directions are measured. Simulated and measured stiffness ratio in horizontal to vertical direction is measured for each design. Effect of the length of the stylus on H:V stiffness ratio is studied. Minimum and maximum deflection and resonance frequency are measured for all designs. The sensors were placed in a nanopositioning and nanomeasuring machine and one point measurements were performed for all the designs. Lastly the application of the sensor is shown, where dimension of a cube is measured using the sensor.
This paper introduces the synchronous micromotor concept and presents new investigations on its application as an integrated driving mechanism in microfluidic systems. A spiral channel viscous micropump and a microstirrer are considered and tested as examples to verify the concept. The fabrication technology of such integrated systems is based on UV depth lithography, electroplating and soft lithography. The synchronous micromotor consists of a stator including double layer coils, and a rotor disk containing alternate permanent magnets. The coils are distributed evenly around the stator and arranged in three phases. The phases are excited by sinusoidal currents with a corresponding phase shift resulting in a rotating magnetic field. Regarding the spiral channel viscous micropump, a spiral disk was fixed onto the rotor disk and run at different rotational speeds. Tests showed very promising results, with a flow rate up to 1023 µL·min−1 at a motor rotational speed of 4500 rpm. Furthermore, for the application of a microstirred-tank bioreactor, the rotor disk design was modified to work as a stirrer. The performance of the developed microbioreactor was tested over a time period of approximately 10 h under constant stirring. Tests demonstrated the successful cultivation of S. cerevisiae through the integration of the microstirrer in a microbioreactor system. These systems prove that synchronous micromotors are well suited to serve as integrated driving mechanisms of active microfluidic components.