The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as well as relative dosimetry when compared to absolute absorbed dose calibrated using ionization chamber results. For comparison, a silver halide film (Kodak EDR-2) representing the current standard in film dosimetry was included. As an initial step a measurement protocol yielding accurate and precise results was established for a flatbed transparency scanner (Epson Expression 1680 Pro) that was utilized as a film reading instrument. The light transmission measured by the scanner was found to depend on the position of the film on the scanner plate. For three film pieces irradiated with doses of 0 Gy, approximately 1 Gy and approximately 7 Gy, the pixel values measured in portrait or landscape mode differed by 4.7%, 6.2% and 10.0%, respectively. A study of 200 film pieces revealed an excellent sheet-to-sheet uniformity. On a long time scale, the optical development of irradiated EBT film consisted of a slow but steady increase of absorbance which was not observed to cease during 4 months. Sensitometric curves of EBT films obtained under reference conditions (SSD = 95 cm, FS = 5 x 5 cm(2), d = 5 cm) for 6, 10 and 25 MV photon beams did not show any energy dependence. The average separation between all curves was only 0.7%. The variation of the depth d (range 2-25 cm) in the phantom did not affect the dose response of EBT film. Also the influence of the radiation field size (range 3 x 3-40 x 40 cm(2)) on the sensitometric curve was not significant. For EDR-2 films maximum differences between the calibration curves reached 7-8% for X6MV and X25MV. Radiochromic EBT film, in combination with a flatbed scanner, presents a versatile system for high-precision dosimetry in two dimensions, provided that the intrinsic behaviour of the film reading device is taken into account. EBT film itself presents substantial improvements on formerly available models of radiographic and a radiochromic film and its dosimetric characteristics allow us to measure absorbed dose levels in a large variety of situations with a single calibration curve.
Recent observations in animal models show that ultra-high dose rate ("FLASH") radiation treatment significantly reduces normal tissue toxicity maintaining an equivalent tumor control. The dependence of this "FLASH" effect on target oxygenation has led to the assumption that oxygen "depletion" could be its major driving force. In a bottom-up approach starting from the chemical track evolution of 1 MeV electrons in oxygenated water simulated with the TRAX-CHEM Monte Carlo code, we determine the oxygen consumption and radiolytic reactive oxygen species production following a short radiation pulse. Based on these values, the effective dose weighted by oxygen enhancement ratio (OER) or the in vitro cell survival under dynamic oxygen pressure is calculated and compared to that of conventional exposures, at constant OER. We find an excellent agreement of our Monte Carlo predictions with the experimental value for radiolytic oxygen removal from oxygenated water. However, the application of the present model to published radiobiological experiment conditions shows that oxygen depletion can only have a negligible impact on radiosensitivity through oxygen enhancement, especially at typical experimental oxygenations where a FLASH effect has been observed. We show that the magnitude and dependence of the "oxygen depletion" hypothesis are not consistent with the observed biological effects of FLASH irradiation. While oxygenation plays an undoubted role in mediating the FLASH effect, we conclude that state-of-the-art radiation chemistry models do not support oxygen depletion and radiation-induced transient hypoxia as the main mechanism.
25 September 2013 in The European Physical Journal D
To incorporate the effects of low energy electrons and positrons into radiation interaction models. The simulation method proposed here was based on experimental and theoretical cross section data and energy loss spectra we have previously derived. After a summary of the main techniques used to obtain reliable input data, the basis of a Low Energy Particle Track Simulation (LEPTS) procedure was established. The programme is specifically designed to describe electron and positron interactions below 10 keV, down to thermal energies. Single electron and positron tracks in water are presented and the possibility of using these results to develop tools for nanodosimetry is discussed. Standard approximations based on high incident energies, such as the Born-Bethe theory, are not suitable to simulate electron and positron tracks below 10 keV. Prior to the inclusion of low-energy effects in a radiation model, an appropriate study is required to determine both the interaction cross sections and the energy loss spectra.
In this paper, we report on total electron tetrahydrofuran scattering cross-section measurements for energies in the range from 50 to 5000 eV with experimental errors of about 5%. In addition, integral elastic and inelastic cross sections have been calculated over a broad energy range , with an optical potential method assuming a screening-corrected independent atom representation. Partial and total ionization cross sections have been also obtained by combining simultaneous electron and ion measurements with a time-of-flight analysis of the ionic induced fragmentation. Finally, an average energy distribution of secondary electrons has been derived from these measurements in order to provide data for modeling electron-induced damage in biomolecular systems.
The radiosensitivity of biological systems is strongly affected by the system oxygenation. On the nanoscopic scale and molecular level, this effect is considered to be strongly related to the indirect damage of radiation. Even though particle track radiolysis has been the object of several studies, still little is known about the nanoscopic impact of target oxygenation on the radical yields. Here we present an extension of the chemical module of the Monte Carlo particle track structure code TRAX, taking into account the presence of dissolved molecular oxygen in the target material. The impact of the target oxygenation level on the chemical track evolution and the yields of all the relevant chemical species are studied in water under different irradiation conditions: different linear energy transfer (LET) values, different oxygenation levels, and different particle types. Especially for low LET radiation, a large production of two highly toxic species ( and ), which is not produced in anoxic conditions, is predicted and quantified in oxygenated solutions. The remarkable correlation between the and production yield and the oxygen enhancement ratio observed in biological systems suggests a direct or indirect involvement of and in the oxygen sensitization effect. The results are in agreement with available experimental data and previous computational approaches. An analysis of the oxygen depletion rate in different radiation conditions is also reported. The radiosensitivity of biological systems is strongly affected by the system oxygenation. On the nanoscopic scale and molecular level, this effect is considered to be strongly related to the indirect damage of radiation. Even though particle track radiolysis has been the object of several studies, still little is known about the nanoscopic impact of target oxygenation on the radical yields. Here we present an extension of the chemical module of the Monte Carlo particle track structure code TRAX, taking into account the presence of dissolved molecular oxygen in the target material. The impact of the target oxygenation level on the chemical track evolution and the yields of all the relevant chemical species are studied in water under different irradiation conditions: different linear energy transfer (LET) values, different oxygenation levels, and different particle types. Especially for low LET radiation, a large production of two highly toxic species ( and ), which is not produced in anoxic conditions, is predicted and quantified in oxygenated solutions. The remarkable correlation between the and production yield and the oxygen enhancement ratio observed in biological systems suggests a direct or indirect involvement of and in the oxygen sensitization effect. The results are in agreement with available experimental data and previous computational approaches. An analysis of the oxygen depletion rate in different radiation conditions is also reported.