Lolli Nicola

Dr. Lolli Nicola


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2019 in Wood Material Science & Engineering
Verified
Journal Article
Closed access
LNLolli Nicola
Lolli Nicola
SFSelamawit Mamo Fufa
Selamawit Mamo Fufa
MWMarianne Kjendseth Wiik
Marianne Kjendseth Wiik
This paper analyses and compares the embodied and operational greenhouse gas (GHG) emissions of two nearly Zero Energy Buildings, a student housing building in Trondheim, Norway, and a residential building in Växjö, Sweden. The student housing in Trondheim, Moholt Allmenning Tower B, is a 9-storey tower composed of cross laminated timber (CLT) panels and concrete floor slabs with a total heated floor area of 3801 m2. The apartment building in Växjö, House A, consists of 8 floors composed of glued laminated timber (glulam) beams with a wood-cassette floor, and concrete slabs with a total heated floor area of 3483 m2. The results show that the use of CLT has the largest reduction of total GHG emissions due to substituting concrete elements in the structural frame. The comparative assessment of the external wall and the internal floor constructions shows that the use of CLT adds marginal GHG emissions per unit of area of component. The calculation of operational GHG emissions shows that the use of the Nordic electricity mix disfavours the full-electric energy system of Moholt Allmenning Tower B, in contrast to the district heating used in Norra Vallen Building A.

22 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
Mattia ManniMattia Manni
Mattia Manni
Gabriele LobaccaroGabriele Lobaccaro
Gabriele Lobaccaro
LNLolli Nicola
Lolli Nicola
RBRolf André Bohne
Rolf André Bohne
This work presents a validated workflow based on an algorithm developed in Grasshopper to parametrically control the building’s shape, by maximizing the solar irradiation incident on the building envelope and minimizing the embodied emissions. The algorithm is applied to a zero-emission building concept in Nordic and Mediterranean climate zones. The algorithm enables conducting both energy and environmental assessments through Ladybug tools. The emissions embodied in materials and the solar irradiation incident on the building envelope were estimated in the early design stage. A three-steps optimization process through evolutionary solvers, such as Galapagos (one-objective) and Octopus (multi-objective), has been conducted to shape the most environmentally responsive ZEB model in both climates. The results demonstrated the replicability of the algorithm to optimize the solar irradiation by producing an increment of solar incident irradiation equal to 35% in the Mediterranean area, and to 20% in the Nordic climate. This could contribute to compensate the additional 15% of emissions due to the higher quantities of employed materials in the optimized design. The developed approach, which is based on the parametric design principles for ZEBs, represents a support instrument for designers to develop highly efficient energy solutions in the early design stages.

1 December 2019 in Journal of Daylighting
Verified
Journal Article
Open access
PDF file
LNLolli Nicola
Lolli Nicola
ANAlessandro Nocente
Alessandro Nocente
JBJohannes Brozovsky
Johannes Brozovsky
RWRuth Woods
Ruth Woods
SGSteinar Grynning
Steinar Grynning
A case study to evaluate the occupants' satisfaction in relation to two different control strategies (fully automatic and manual) for blind and ceiling lights use in cell offices was carried on in Trondheim, Norway. A group of 11 participants with varying age, gender, and ethnicity, used two test cells of a laboratory as a workspace primarily carrying out office tasks at a personal computer for a total of 19 calendar days. The participants were asked to answer a computer-based questionnaire for reporting their perceived thermal and visual comfort. Concurrently, measurements of the indoor operative temperature, illuminance level, and operation of windows, blinds, and ceiling lights were registered. Results shows that the use of the automatic control strategy led to a higher visual discomfort, which in addition led to a higher thermal discomfort, despite this last not caused by a higher average operative temperature. Header of solarlits.com

27 April 2020 in Buildings
Verified
Journal Article
Open access
PDF file
LNLolli Nicola
Lolli Nicola
ANAlessandro Nocente
Alessandro Nocente
SGSteinar Grynning
Steinar Grynning
The influence of different control strategies on the user’s satisfaction in cell offices was studied in a full-scale facility in Trondheim, Norway. Eleven participants used two test cells as a workspace and answered a computer-based questionnaire for reporting their perceived thermal and visual comfort, and any desired changes in the cell environment. Concurrently, the indoor operative temperature and illuminance were registered. Two different strategies for controlling the indoor environment were used in the case study. In Cell A, the ceiling-mounted lights, the window blind, and a water-based radiator were controlled by the main acquisition and control system, whereas in Cell B, these were manually controlled by the users. In both cells, the window opening was user-controlled, except for a small motorised window, which was automated in Cell A, and user-controlled in Cell B. The results show that the occupants of Cell B first tended to open the window, then to adjust their clothing level, and finally to lower the blind when the operative temperature increased. The recorded Thermal Sensation Votes (TSVs) and Illuminance Ratings (IRs) show that the limitation of control opportunities in Cell A increases the level of thermal and visual dissatisfaction.

28 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
LNLolli Nicola
Lolli Nicola
EGEvgenia Gorantonaki
Evgenia Gorantonaki
JCJohn Clauß
John Clauß
An office building in Trondheim, Norway, was used as a case study to test the influence of Predictive Control (PC) for the optimization of energy use on the employees’ thermal comfort. A predictive control was implemented in the Building Energy Management System (BEMS) by operating on the supply temperature of the radiator circuit. A questionnaire was given to the employees to evaluate to what extent the operation of the predictive control influenced their perceived thermal comfort. Several factors known to influence employees’ satisfaction (such as office type, perceived noise level, level of control, perceived luminous environment, perceived indoor air quality, adaptation strategies, well-being) were investigated in the questionnaire. The evaluation shows that the occupants rated the perceived thermal comfort as equally good compared to the business-as-usual operation. This is an important finding toward the user acceptance of such predictive control schemes.

30 November 2020 in Buildings
Verified
Journal Article
Open access
PDF file
LNLolli Nicola
Lolli Nicola
ALAnne Gunnarshaug Lien
Anne Gunnarshaug Lien
ØRØystein Rønneseth
Øystein Rønneseth
The cost-effectiveness of energy efficiency measures meant to achieve a zero-emission office building is investigated and compared to business as usual energy efficiency measures. The laboratory for zero emission buildings, the ZEB Lab, located in Trondheim, Norway, is an office building designed and built to compensate its lifecycle emissions with the use of a large array of building-integrated photovoltaic panels, pursuing a zero-emissions ambition level. Three design alternatives are investigated by downgrading the building insulation level to the values recommended by the currently enforced Norwegian building code, the byggteknisk forskrift TEK17. A sensitivity analysis of the variation of the installed area of the photovoltaic panels is performed to evaluate if smaller areas give better cost performances. Net present values are calculated by using three scenarios of future increase of electricity price for a time horizon of 20 years. Results show that business as usual solutions give higher net present values. Optimized areas of the photovoltaic panels further increase the net present values of the business as usual solutions in the highest electricity price scenario. The zero-emission ambition level shows a higher net present value than that of the business as usual solutions for a time horizon of at least 36 years.