Alessandro Nocente

Dr. Alessandro Nocente

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2022 in Energy Research & Social Science
Verified
Journal Article
Closed access
RCRoberta Jacoby Cureau
Roberta Jacoby Cureau
Ilaria PigliautileIlaria Pigliautile
Ilaria Pigliautile
Anna Laura PiselloAnna Laura Pisello
Anna Laura Pisello
MBMateus Bavaresco
Mateus Bavaresco
CBChristiane Berger
Christiane Berger
AWA. Wang
A. Wang

1 December 2019 in Journal of Daylighting
Verified
Journal Article
Open access
PDF file
LNLolli Nicola
Lolli Nicola
ANAlessandro Nocente
Alessandro Nocente
JBJohannes Brozovsky
Johannes Brozovsky
RWRuth Woods
Ruth Woods
SGSteinar Grynning
Steinar Grynning
A case study to evaluate the occupants' satisfaction in relation to two different control strategies (fully automatic and manual) for blind and ceiling lights use in cell offices was carried on in Trondheim, Norway. A group of 11 participants with varying age, gender, and ethnicity, used two test cells of a laboratory as a workspace primarily carrying out office tasks at a personal computer for a total of 19 calendar days. The participants were asked to answer a computer-based questionnaire for reporting their perceived thermal and visual comfort. Concurrently, measurements of the indoor operative temperature, illuminance level, and operation of windows, blinds, and ceiling lights were registered. Results shows that the use of the automatic control strategy led to a higher visual discomfort, which in addition led to a higher thermal discomfort, despite this last not caused by a higher average operative temperature. Header of solarlits.com

6 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Mattia ManniMattia Manni
Mattia Manni
ANAlessandro Nocente
Alessandro Nocente
Martin BellmannMartin Bellmann
Martin Bellmann
Gabriele LobaccaroGabriele Lobaccaro
Gabriele Lobaccaro
Evaluating how the sources of uncertainty in solar modelling (e.g., input parameters, developed model chain) can influence the results’ accuracy is one of the main challenges when applied at high latitudes. In this study, a multi-stage validation workflow is implemented around five main stages: data acquisition, data quality check, solar radiation modelling, photovoltaic energy modelling, and experimental validation. Different data sources such as satellite observations, numerical reanalysis, and on-site ground measurements are considered as inputs, while the outcomes from each step of the model chain (e.g., decomposition modelling, transposition modelling, photovoltaic energy modelling) are compared against observations recorded from the solar radiation network at the Norwegian University of Science and Technology (NTNU-Solarnet) in Trondheim (Norway). In the first and second validation stages, the decomposition and transposition models with measured input parameters show the best accuracy indicators, but they do not fulfill the validation criteria. Conversely, in the third validation stage, the photovoltaic energy models with on-site ground measurements as inputs are experimentally validated. In conclusion, at high latitudes, the most accurate results are obtained when monitored solar irradiation data are used instead of satellite observations and numerical reanalysis. Furthermore, the shortest model chain is preferred, with equal data sources.

17 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
ANAlessandro Nocente
Alessandro Nocente
TATufan Arslan
Tufan Arslan
SGSteinar Grynning
Steinar Grynning
FGFrancesco Goia
Francesco Goia
Diffuse Ceiling Ventilation (DCV) is a promising concept to address internal air quality and thermal comfort requirements in contemporary buildings. Sound-absorbing perforated ceiling panels are common in office rooms and can be used as air diffusers without modifications. The optimization of such systems is not a trivial procedure, and numerical simulation can represent an important tool to carry out this task. Today, most of the numerical studies on DCV are performed using porous medium models and focus on the general system performance rather than on the optimization of the diffuser design. In previous studies, a CFD model was used to optimize the size and distribution of the ceiling perforation. In the study presented in this paper, the results of simulations conducted on a full-scale three-dimensional domain and the performance comparison between a continuous and non-continuous perforation distribution are given. The results show that the non-continuous diffuser design does not disturb the internal comfort and does not introduce a negative effect in the system performance. The different configurations lead to a different air distribution in the room, but in both cases, the velocity magnitude is always well below values leading to draft discomfort.

13 December 2022 in Building and Environment
Verified
Journal Article
Open access
JBJohannes Brozovsky
Johannes Brozovsky
ANAlessandro Nocente
Alessandro Nocente
PRPetra Rüther
Petra Rüther

27 April 2020 in Buildings
Verified
Journal Article
Open access
PDF file
LNLolli Nicola
Lolli Nicola
ANAlessandro Nocente
Alessandro Nocente
SGSteinar Grynning
Steinar Grynning
The influence of different control strategies on the user’s satisfaction in cell offices was studied in a full-scale facility in Trondheim, Norway. Eleven participants used two test cells as a workspace and answered a computer-based questionnaire for reporting their perceived thermal and visual comfort, and any desired changes in the cell environment. Concurrently, the indoor operative temperature and illuminance were registered. Two different strategies for controlling the indoor environment were used in the case study. In Cell A, the ceiling-mounted lights, the window blind, and a water-based radiator were controlled by the main acquisition and control system, whereas in Cell B, these were manually controlled by the users. In both cells, the window opening was user-controlled, except for a small motorised window, which was automated in Cell A, and user-controlled in Cell B. The results show that the occupants of Cell B first tended to open the window, then to adjust their clothing level, and finally to lower the blind when the operative temperature increased. The recorded Thermal Sensation Votes (TSVs) and Illuminance Ratings (IRs) show that the limitation of control opportunities in Cell A increases the level of thermal and visual dissatisfaction.