Mei-Ying Kuo

Prof. Mei-Ying Kuo

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2021 in Toxins
Verified
Journal Article
Open access
PDF file
NDNhan Doan
Nhan Doan
MKMei-Ying Kuo
Mei-Ying Kuo
Li-Wei ChouLi-Wei Chou
Li-Wei Chou
Post-stroke spasticity impedes patients’ rehabilitation progress. Contradictory evidence has been reported in using Botulinum Neurotoxin type A (BoNT-A) to manage post-stroke lower extremity spasticity (PLES); furthermore, an optimum dose of BoNT-A for PLES has not yet been established. Therefore, we conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) to identify the efficacy and optimal dose of BoNT-A on PLES. "Meta" and "Metafor" packages in R were used to analyze the data. Hedges’ g statistic and random effect model were used to calculate and pool effect sizes. Twelve RCTs met the eligibility criteria. Muscle tone significantly improved in week four, week eight, and maintained to week twelve after BoNT-A injection. Improvements in functional outcomes were found, some inconsistencies among included studies were noticed. Dosage analysis from eight studies using Botox® and three studies using Dysport® indicated that the optimum dose for the commonest pattern of PLES (spastic plantar flexors) is medium-dose (approximately 300U Botox® or 1000 U Dysport®). BoNT-A should be regarded as part of a rehabilitation program for PLES. Furthermore, an optimal rehabilitation program combined with BoNT-A management needs to be established. Further studies should also focus on functional improvement by BoNT-A management in the early stage of stroke.

20 December 2013 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CKChien-Chung Kuo
Chien-Chung Kuo
HLHsuan-Lun Lu
Hsuan-Lun Lu
Tung-Wu LuTung-Wu Lu
Tung-Wu Lu
Cheng-Chung LinCheng-Chung Lin
Cheng-Chung Lin
Alberto LeardiniAlberto Leardini
Alberto Leardini
HHHorng-Chaung Hsu
Horng-Chaung Hsu
Measurements of the morphology of the ankle joint, performed mostly for surgical planning of total ankle arthroplasty and for collecting data for total ankle prosthesis design, are often made on planar radiographs, and therefore can be very sensitive to the positioning of the joint during imaging. The current study aimed to compare ankle morphological measurements using CT-generated 2D images with gold standard values obtained from 3D CT data; to determine the sensitivity of the 2D measurements to mal-positioning of the ankle during imaging; and to quantify the repeatability of the 2D measurements under simulated positioning conditions involving random errors. Fifty-eight cadaveric ankles fixed in the neutral joint position (standard pose) were CT scanned, and the data were used to simulate lateral and frontal radiographs under various positioning conditions using digitally reconstructed radiographs (DRR). In the standard pose for imaging, most ankle morphometric parameters measured using 2D images were highly correlated (R > 0.8) to the gold standard values defined by the 3D CT data. For measurements made on the lateral views, the only parameters sensitive to rotational pose errors were longitudinal distances between the most anterior and the most posterior points of the tibial mortise and the tibial profile, which have important implications for determining the optimal cutting level of the bone during arthroplasty. Measurements of the trochlea tali width on the frontal views underestimated the standard values by up to 31.2%, with only a moderate reliability, suggesting that pre-surgical evaluations based on the trochlea tali width should be made with caution in order to avoid inappropriate selection of prosthesis sizes. While highly correlated with 3D morphological measurements, some 2D measurements were affected by the bone poses in space during imaging, which may affect surgical decision-making in total ankle arthroplasty, including the amount of bone resection and the selection of the implant sizes. The linear regression equations for the relationship between 2D and 3D measurements will be helpful for correcting the errors in 2D morphometric measurements for clinical applications.

26 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Cheng-Chung LinCheng-Chung Lin
Cheng-Chung Lin
Tung-Wu LuTung-Wu Lu
Tung-Wu Lu
JLJia-Da Li
Jia-Da Li
MKMei-Ying Kuo
Mei-Ying Kuo
CKChien-Chung Kuo
Chien-Chung Kuo
HHHorng-Chuang Hsu
Horng-Chuang Hsu
Model-based tracking of the movement of the tibiofemoral joint via a biplane X-ray imaging system has been commonly used to reproduce its accurate, three-dimensional kinematics. To accommodate the approaches to existing clinical asynchronous biplane fluoroscopy systems and achieve comparable accuracy, this study proposed an automated model-based interleaved biplane fluoroscopy image tracking scheme (MIBFT) by incorporating information of adjacent image frames. The MIBFT was evaluated with a cadaveric study conducted on a knee specimen. The MIBFT reproduced skeletal poses and tibiofemoral kinematics that were in good agreement with the standard reference kinematics provided by an optical motion capture system, in which the root-mean-squared (Rms) errors of the skeletal pose parameters ranged from 0.11 to 0.35 mm in translation and 0.18 to 0.49° in rotation. The influences of rotation speed on the pose errors were below 0.23 mm and 0.26°. The MIBFT-determined bias, precision, and Rms error were comparable to those of the reported model-based tracking techniques using custom-made synchronous biplane fluoroscopy. The results suggested that the further use of the clinical imaging system is feasible for the noninvasive and precise examination of dynamic joint functions and kinematics in clinical practice and biomechanical research.

5 August 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CKChien-Chung Kuo
Chien-Chung Kuo
HLHsuan-Lun Lu
Hsuan-Lun Lu
Tung-Wu LuTung-Wu Lu
Tung-Wu Lu
Alberto LeardiniAlberto Leardini
Alberto Leardini
MKMei-Ying Kuo
Mei-Ying Kuo
HHHorng-Chaung Hsu
Horng-Chaung Hsu
Clinical success of total ankle arthroplasty depends heavily on the available information on the morphology of the bones, often obtained from measurements on planar radiographs. The current study aimed to evaluate the intra-rater, inter-rater and inter-session reliability and the validity of radiograph-based measurements of ankle morphology, and to quantify the effects of examiner experience on these measurements. Twenty-four fresh frozen ankle specimens were CT scanned, data of which were used to reconstruct 3D volumetric bone models for synthesizing 2D radiographs. Two orthopaedic surgeons with different levels of clinical experience identified twenty landmarks five times on each of the synthesized sagittal and coronal radiographs and repeated the test on a subsequent day within 5 days. The landmarks were used to calculate fourteen morphological parameters. The two-way mixed-effects (ICC3,1), two-way random-effects (ICC2,k) and two-way random-effects (ICC3,k) models were used, respectively, to assess the intra-rater, inter-rater and inter-session reliability of measurements. The validity of the measurements for each examiner was assessed by comparing them with gold standard values obtained from the 2D radiographs projected from the 3D volumetric models using Pearson’s correlation analysis and Bland and Altman plots, and the differences were defined as the measurement errors. Most of the morphological parameters were of good to very good intra-rater, inter-session and inter-rater reliability for both examiners (ICC > 0.61). Experience appeared to affect the inter-rater and inter-session reliability, the senior examiner showing greater inter-session ICC values than the junior examiner. Most of the tibial parameters had moderate to excellent correlations with the corresponding gold standard values but were underestimated by both examiners, in contrast to most of the talar parameters that were overestimated and had only poor to fair correlations. Most of the morphological parameters of the ankle can be estimated from radiographs with good to very good intra-rater, inter-session and inter-rater reliability, for both clinically experienced and less experienced examiners. Clinical experience helped increase the reliability of repeated evaluations after a longer interval, such as in a follow-up assessment. It is suggested that critical clinical decisions based on repeated morphology measurements should be made by more experienced surgeons or after appropriate training.

7 June 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
HHHong-Jung Hsieh
Hong-Jung Hsieh
CHChih-Chung Hu
Chih-Chung Hu
Tung-Wu LuTung-Wu Lu
Tung-Wu Lu
HLHsuan-Lun Lu
Hsuan-Lun Lu
MKMei-Ying Kuo
Mei-Ying Kuo
HHHorng-Chaung Hsu
Horng-Chaung Hsu
Robot-based joint-testing systems (RJTS) can be used to perform unconstrained laxity tests, measuring the stiffness of a degree of freedom (DOF) of the joint at a fixed flexion angle while allowing the other DOFs unconstrained movement. Previous studies using the force-position hybrid (FPH) control method proposed by Fujie et al. (J Biomech Eng 115(3):211–7, 1993) focused on anterior/posterior tests. Its convergence and applicability on other clinically relevant DOFs such as valgus/varus have not been demonstrated. The current s1tudy aimed to develop a 6-DOF RJTS using an industrial robot, to propose two new force-position hybrid control methods, and to evaluate the performance of the methods and FPH in controlling the RJTS for anterior/posterior and valgus/varus laxity tests of the knee joint. An RJTS was developed using an industrial 6-DOF robot with a 6-component load-cell attached at the effector. The performances of FPH and two new control methods, namely force-position alternate control (FPA) and force-position hybrid control with force-moment control (FPHFM), for unconstrained anterior/posterior and valgus/varus laxity tests were evaluated and compared with traditional constrained tests (CT) in terms of the number of control iterations, total time and the constraining forces and moments. As opposed to CT, the other three control methods successfully reduced the constraining forces and moments for both anterior/posterior and valgus/varus tests, FPHFM being the best followed in order by FPA and FPH. FPHFM had root-mean-squared constraining forces and moments of less than 2.2 N and 0.09 Nm, respectively at 0° flexion, and 2.3 N and 0.14 Nm at 30° flexion. The corresponding values for FPH were 8.5 N and 0.33 Nm, and 11.5 N and 0.45 Nm, respectively. Given the same control parameters including the compliance matrix, FPHFM and FPA reduced the constraining loads of FPH at the expense of additional control iterations, and thus increased total time, FPA taking about 10 % longer than FPHFM. The FPHFM would be the best choice among the methods considered when longer total time is acceptable in the intended clinical applications. The current results will be useful for selecting a force-position hybrid control method for unconstrained laxity tests using an RJTS.

11 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Cheng-Chung LinCheng-Chung Lin
Cheng-Chung Lin
HLHsuan-Lun Lu
Hsuan-Lun Lu
Tung-Wu LuTung-Wu Lu
Tung-Wu Lu
CWChia-Yang Wang
Chia-Yang Wang
JLJia-Da Li
Jia-Da Li
HHHorng-Chuang Hsu
Horng-Chuang Hsu
Model-based 3D/2D image registration using single-plane fluoroscopy is a common setup to determine knee joint kinematics, owing to its markerless aspect. However, the approach was subjected to lower accuracies in the determination of out-of-plane motion components. Introducing additional kinematic constraints with an appropriate anatomical representation may help ameliorate the reduced accuracy of single-plane image registration. Therefore, this study aimed to develop and evaluate a multibody model-based tracking (MbMBT) scheme, embedding a personalized kinematic model of the tibiofemoral joint for the measurement of tibiofemoral kinematics. The kinematic model was consisted of three ligaments and an articular contact mechanism. The knee joint activities in six volunteers during isolated knee flexion, lunging, and sit-to-stand motions were recorded with a biplane X-ray imaging system. The tibiofemoral kinematics determined with the MbMBT and mediolateral view fluoroscopic images were compared against those determined using biplane fluoroscopic images. The MbMBT was demonstrated to yield tibiofemoral kinematics with precision values in the range from 0.1 mm to 1.1 mm for translations and from 0.2° to 1.3° for rotations. The constraints provided by the kinematic model were shown to effectively amend the nonphysiological tibiofemoral motion and not compromise the image registration accuracy with the proposed MbMBT scheme.