vincent kerzerho

vincent kerzerho

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Fishes
Verified
Journal Article
Open access
PDF file
VKvincent kerzerho
vincent kerzerho
FAFlorence Azaïs
Florence Azaïs
SBSerge Bernard
Serge Bernard
SBSylvain Bonhommeau
Sylvain Bonhommeau
BBBlandine Brisset
Blandine Brisset
FSFabien Soulier
Fabien Soulier
Repeated fish handling may cause stress, which biases experiments and so affects the results. In order to reduce this, the present study investigates the benefit of using bioimpedance analysis to estimate morphological parameters. Bioimpedance analysis is a non-lethal and integrative electrical measurement that can be used to estimate several kinds of physiological parameters and is used in medicine and ecological studies. In particular, bioimpedance can monitor the individual growth of fish, which is a prerequisite for most biological and ecological studies, as body size is one of the best predictors for numerous life history traits and ecological parameters. After a short review on the use of bioimpedance measurement in medicine and ecology, we illustrate the potential of bioimpedance spectroscopy, as opposed to single frequency measurement, for experimental studies on fish. Using a monolithic four-contact electrode and a cost-effective portable system, we conducted bioimpedance spectroscopy on 159 sardines. The association between the length, weight, and electrical parameters obtained at different frequencies from the bioimpedance spectroscopy was investigated. Our results show that accounting for more than one frequency substantially improves the prediction of length and weight. We conclude that bioimpedance could potentially be a powerful tool for monitoring fish growth in ecological studies.

10 February 2018 in Journal of Electronic Testing
Verified
Journal Article
Closed access
PDF file
SDStephane David-Grignot
Stephane David-Grignot
ALAchraf Lamlih
Achraf Lamlih
MBMohamed Moez Belhaj
Mohamed Moez Belhaj
VKvincent kerzerho
vincent kerzerho
FAFlorence Azaïs
Florence Azaïs
SBSerge Bernard
Serge Bernard

1 July 2020
Verified
Conference Paper
Open access
FAF. Azais
F. Azais
SBSerge Bernard
Serge Bernard
MCM. Comte
M. Comte
BDBastien Deveautour
Bastien Deveautour
Sophie DupuisSophie Dupuis
Sophie Dupuis
AVA. Virazel
A. Virazel
Systems on a chip have seen their surface area increased by a factor of 10 and their consumption multiplied by 5 during the last ten years. Each technological node that enabled this integration has also added new constraints challenging the overall system reliability. In addition, the integration of analog/RF blocks adds specific issues, in particular the high cost of the required test equipment. It is therefore necessary to improve test and reliability solutions in order to guarantee the production yield and the system life-time. Moreover, the massive increase in the use of communicating systems has introduced security as a cornerstone of their development. The entire hardware production flow is therefore subject to security and trust issues requiring the development of dedicated test solutions. In this paper, we focus on LIRMM contributions in the HADES project especially with details on Embedded Test Instruments (ETIs) for reliability of digital ICs, low-cost RF test based on indirect DC measurements or digital ATE capture, management of secure scan access.

27 February 2023
Verified
Book Chapter
Closed access
PDF file
SPStéphane Pitou
Stéphane Pitou
TRTristan Rouyer
Tristan Rouyer
SBSylvain Bonhommeau
Sylvain Bonhommeau
SBSerge Bernard
Serge Bernard
FSFabien Soulier
Fabien Soulier
VKvincent kerzerho
vincent kerzerho

1 January 2022 in Aquaculture
Verified
Journal Article
Closed access
EDEloïse Detrez
Eloïse Detrez
VKvincent kerzerho
vincent kerzerho
MBMohamed-Moez Belhaj
Mohamed-Moez Belhaj
AVAlain Vergnet
Alain Vergnet
HVHugues de Verdal
Hugues de Verdal
FSFabien Soulier
Fabien Soulier

1 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FSFabien Soulier
Fabien Soulier
ALAchraf Lamlih
Achraf Lamlih
VKvincent kerzerho
vincent kerzerho
SBSerge Bernard
Serge Bernard
TRTristan Rouyer
Tristan Rouyer
Bioimpedance spectroscopy consists of measuring the complex impedance of biological tissues over a large frequency domain. This method is particularly convenient for physiological studies or health monitoring systems. For a wide range of applications, devices need to be portable, wearable or even implantable. Next generation of bioimpedance sensing systems thus require to be implemented with power and resource savings in mind. Impedance measurement methods are divided into two main categories. Some are based on “single-tone” signals while the others use “multi-tone” signals. The firsts benefit from a very simple analysis that may consist of synchronous demodulation. However, due to necessary frequency sweep, the total measurement may take a long time. On the other hand, generating a multi-frequency signal allows the seconds to cover the whole frequency range simultaneously. This is at the cost of a more complex analysis algorithm. This makes both approaches hardly suitable for embedded applications. In this paper, we propose an intermediate approach that combines the speed of multi-tone systems with a low-resource analysis algorithm. This results in a minimal implementation using only adders and synchronous adc. For optimal performances, this small footprint digital processing can be synthesized and embedded on a mixed-mode integrated circuit together with the analog front-end. Moreover, the proposed implementation is easily scalable to fit an arbitrary frequency range. We also show that the resulting impact on noise sensitivity can be mitigated.