Shuhui Liu

Dr. Shuhui Liu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
SWShun Wang
Shun Wang
SLShuhui Liu
Shuhui Liu
WNWenjun Ni
Wenjun Ni
SWShun Wu
Shun Wu
PLPeixiang Lu
Peixiang Lu
We report and demonstrate a highly-sensitive refractive index (RI) sensor based on a linear-cavity dual-wavelength erbium-doped fiber laser (DWEDFL). The optical spectrum of the laser varies as the external environmental RI changes from 1.3 to 1.335. The DWEDFL has a linear-cavity configuration with two fiber Bragg gratings (FBGs) with central wavelengths < 1 nm apart. Since both FBGs share the same EDF gain medium, gain competition occurs in the cavity. Optical loss of one wavelength can be introduced by immersing the sensing component, a 15 mm micro-fiber (MF), in a solution under test. Experimental results demonstrate a high sensitivity of −231.1 dB/RIU (refractive index unit) and 42.6 dB/RIU in the range from 1.300 to 1.335. The relative power change at the two FBG wavelengths reveals a higher sensitivity of −273.7 dB/RIU with better stability due to reduced light source jitter and external perturbation. Due to its high sensitivity and simple structure, the dual wavelengths gain competition RI sensor has potential applications in chemical and biochemical sensing fields.

6 April 2018 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
XXXizhen Xu
Xizhen Xu
Jun HeJun He
Jun He
MHMaoxiang Hou
Maoxiang Hou
SLShuhui Liu
Shuhui Liu
ZBZhiyong Bai
Zhiyong Bai
Yiping WangYiping Wang
Yiping Wang
A Fabry-Perot interferometer (FPI) composed of a miniature fiber collimator is proposed and demonstrated for high-sensitivity bend measurements. The device consists of a quarter-pitch graded index fiber (GIF) spliced with a section of silica tube, which is interposed between single-mode fibers. The divergence angle of the included miniature fiber collimator was 0.058 rad, which was found to enhance the sensitivity of the proposed FPI to -3.353 dB/degree over the applied angle range. In comparison, the divergence angle without the collimator was 0.130 rad and FPI sensitivity was -0.618 dB/degree over the applied angle range. The fiber bend sensors demonstrated in this paper are compact, robust, and highly sensitive, and hence, are promising in various biomedical applications.

20 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SLShuhui Liu
Shuhui Liu
SCshaoqing cao
shaoqing cao
ZZZhe Zhang
Zhe Zhang
YWYing Wang
Ying Wang
Changrui LiaoChangrui Liao
Changrui Liao
Yiping WangYiping Wang
Yiping Wang
A highly sensitive temperature sensor based on surface plasmon resonance (SPR) of a side-polished single mode fiber is demonstrated. The sensor consists of a gold film coated side-polished fiber covered by a layer of UV-curable adhesive. Before introducing the UV-curable adhesive, the gold-coated fiber exhibits refractive index (RI) sensitivity of 1691.6 nm/RIU to 8800 nm/RIU in the range of 1.32 to 1.43. The resonant wavelength of the SPR sensor shifts to 650 nm when the adhesive is coated on the gold film, and is fixed at about 725 nm when the adhesive is cured. Due to the high thermo-optic and thermal expansion coefficient of the adhesive, the sensor structure achieves a temperature sensitivity of −0.978 nm/°C between 25 °C and 100 °C. The proposed optical fiber SPR sensor is simple, highly sensitive and cost effective, which may find potential applications for temperature measurements in the biomedical and environmental industries.

24 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YHYijian Huang
Yijian Huang
SLShuhui Liu
Shuhui Liu
LZLichao Zhang
Lichao Zhang
Yiping WangYiping Wang
Yiping Wang
Yiping WangYiping Wang
Yiping Wang
A high sensitivity fiber-optic sensor based on self-imaging effect in a hollow-core capillary waveguide (HCCW) is presented for sensing applications. The sensor is composed of a section of HCCW fusion spliced between single mode fibers (SMFs). The self-imaging effect in the HCCW is investigated with different fiber lengths and arc-fusion parameters. By infiltrating the hollow core with index matching liquids, the peak wavelength of the proposed device shifts towards longer wavelengths. The temperature and refractive index (RI) responses of the sensor are studied systematically. When temperature is increased from 25 °C to 75 °C, the temperature sensitivity of the device can be improved significantly with the infiltrated structure, and reaches −0.49 nm/°C, compared with that of the un-filled device, which is 9.8 pm/°C. For the RI response, the liquid-filled structure achieves sensitivity of 12,005 nm/RIU in the range between 1.448 and 1.450, slightly higher than the 11,920 nm/RIU achieved by the un-filled one. The proposed sensor exhibits the advantages of simple structure, high sensitivity and low cost, which may find potential applications in physical and chemical sensing.

3 January 2025 in Frontiers in Physics
Verified
Journal Article
Open access
PDF file
LSLan Su
Lan Su
XQXin Qiu
Xin Qiu
RGRui Guo
Rui Guo
YJYoubo Jing
Youbo Jing
CYChaosan Yang
Chaosan Yang
SLShuhui Liu
Shuhui Liu
Femtosecond laser with pulse duration of 35 fs is used to introduce optical breakdown in water and ethanol. The initial dynamics of the laser-introduced break down is investigated with a time resolved shadow imaging method. The motion of the shock wave front at 600 ps, 4 ns, 12 ns, 16 ns, and 20 ns are observed. Experimental results indicate that under the same laser energy, the initial velocity of the shock wave generated in ethanol is slightly lower than that in water. This is mainly determined by liquid properties (viscosity coefficient, density, molecular weight, breakdown threshold). The evolution of the shock wave also indicates that the velocity decreases with time, and the decrease in ethanol is faster than that in water.