Chia Kwang Tan

Dr. Chia Kwang Tan


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2018 in Energies
Verified
Journal Article
Open access
PDF file
JTJ.C. Teo
J.C. Teo
RTRodney Tan
Rodney Tan
VMV. H. Mok
V. H. Mok
VRVigna Kumaran Ramachandaramurthy
Vigna Kumaran Ramachandaramurthy
CTChia Kwang Tan
Chia Kwang Tan
A photovoltaic system is highly susceptible to partial shading. Based on the functionality of a photovoltaic system that relies on solar irradiance to generate electrical power, it is tacitly assumed that the maximum power of a partially shaded photovoltaic system always decreases as the shading heaviness increases. However, the literature has reported that this might not be the case. The maximum power of a partially shaded photovoltaic system under a fixed configuration and partial shading pattern can be highly insusceptible to shading heaviness when a certain critical point is met. This paper presents an investigation of the impact of partial shading and the critical point that reduce the susceptibility of shading heaviness. Photovoltaic string formed by series-connected photovoltaic modules is used in this research. The investigation of the P-V characteristic curve under different numbers of shaded modules and shading heaviness suggests that the photovoltaic string becomes insusceptible to shading heaviness when the shaded modules irradiance reaches a certain critical point. The critical point can vary based on the number of the shaded modules. The formulated equation in this research contributes to determining the critical point for different photovoltaic string sizes and numbers of shaded modules in the photovoltaic string.

10 November 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JWJorinda Yuh Ru Wong
Jorinda Yuh Ru Wong
CTChia Kwang Tan
Chia Kwang Tan
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
HCHang Seng Che
Hang Seng Che
The advancements in smart grid technologies had brought forth the prospect of self-healing distribution grid through intentional islanding, aided by the steadily rising penetration of inverter-based distributed generations (IBDGs). Adaptive protection is the key enabler for this resilient grid architecture. For cost-effectiveness, overcurrent relays (OCRs) with adaptive features had been proposed, often with the sensitivity problem due to low short-circuit current magnitude from the IBDG taken into consideration and largely addressed. However, apart from this widely discussed sensitivity problem, there is an underlying issue on selectivity of the OCR which is frequently disregarded when designing an adaptive overcurrent protection scheme for IBDG dominated microgrid. This selectivity problem is mainly caused by the current diversion to load during fault, which is often disregarded when performing OCR grading for a conventional grid. In this paper, this selectivity problem of the OCR is discussed in depth through a comparative study of conventional grid and a modern IBDG dominated grid. The coordination time interval margin violations problems are demonstrated through theoretical calculations and real-time hardware-in-the-loop experiments. This research aims to provide better insights into the selectivity problem as a step towards achieving a cost-effective yet reliable overcurrent-based adaptive protection for IBDG dominated microgrid.

12 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
JCJordi Cravioto
Jordi Cravioto
Hideaki OhgakiHideaki Ohgaki
Hideaki Ohgaki
HCHang Seng Che
Hang Seng Che
CTChia Kwang Tan
Chia Kwang Tan
SKSatoru Kobayashi
Satoru Kobayashi
Hooman FarzanehHooman Farzaneh
Hooman Farzaneh
Despite the general agreement about the benefits that electrification brings to well-being, few studies have concentrated on the actual effects of electrification on the diverse non-economic dimensions of quality of life (QoL). In a multi-disciplinary and cross-institutional effort, a group of natural and social scientists have studied three electrification schemes (grid extension, centralised hybrid, and solar home systems) in four rural villages in Malaysia, Cambodia, and Myanmar. Using a novel approach with scales on several QoL measures (self-reported QoL and five QoL sub-domains; psychological, physical, social, and economic well-being; occupations; and total active time), this article presents an analysis of the effects of rural electrification on human well-being. With original data surveyed in the villages through a baseline prior to electrification and an endpoint several months after, the effects were examined through suitable statistical methods. Overall, we confirmed a positive effect of electrification in self-reported QoL levels as well as psychological, physical, and social well-being. There was, however, a certain reduction recorded in economic well-being. In the sub-domains of QoL, there were no changes after electrification in satisfaction levels concerning time use, time spent alone, housing, and personal safety, but a positive effect on satisfaction levels was observed in cooking. Finally, in terms of occupation, we observed no changes in the total hours dedicated to work and no prolonged active time on usual activities in the household. The findings provide support to the hypothesis of a positive effect on general QoL from electrification, but also suggest more precisely that, for specific QoL sub-domains, the effect might not necessarily exist, or in fact, may be negative. The article concludes by discussing differences determined by cultural aspects and technological limitations in each of the systems under study.

19 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
MKMuthu Kumaran
Muthu Kumaran
Md HasanuzzamanMd Hasanuzzaman
Md Hasanuzzaman
CTChia Kwang Tan
Chia Kwang Tan
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
VPVignes Ponniah
Vignes Ponniah
In the domain of energy consumption in restaurant-type commercial buildings, traditional energy audits tend to concentrate mainly on electrical loads, often neglecting the specifics of the restaurant sector, especially regarding liquified petroleum gas fuel consumption. This research employs a comprehensive energy audit framework specifically designed for the commercial building restaurant sector. Using energy data from 130 restaurants, we computed the building energy index that ranged in between 650 and 1000 kWh/m2/year. Using linear regression, we assessed the relationship between building energy index and restaurant area, uncovering a low R2 value, suggesting the unsuitability of the building energy index as an exclusive measure for restaurants. Concurrently, our detailed comparative study showed that liquified petroleum gas-fueled equipment uses about 38% more energy than electric fueled equipment but is 0.5% cheaper and significantly less polluting. Investigating renewable energy potentials, we found solar PV application as a viable option for restaurants. The results showed that solar PV installation could produce approximately 11,064,898 kWh, translating to utility savings of RM 7,381,929 and reductions of 7,108,327 kgCO2, 68,959 kgSO2, and 31,823 kgCO emissions. Conclusively, our findings underline the need for a diversified energy assessment in restaurants and the tangible benefits of renewable energy integration.

7 November 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JWJunying Wong
Junying Wong
CTChia Kwang Tan
Chia Kwang Tan
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
RTRodney Tan
Rodney Tan
Adaptive protection schemes (APS) have gained prominence in maintaining the integrity of overcurrent relay (OCR) settings in reconfigurable networks. While many APSs rely on supervisory control and data acquisition systems, they are very expensive and expose the system to vulnerabilities arising from communication failures. Recent studies have proposed communication-less APSs to address this issue by relying on data-mining algorithms equipped with real-time fault voltage-current information. However, the OCR settings are computed and updated as the fault occurs, inevitably causing prolonged OCR tripping in these schemes. This contradicts with the APS’ original purpose of minimizing OCR operation time and consequent equipment damage. Thus, a load flow-based APS that addresses this flaw is proposed to achieve primary-backup OCR coordination in a highly reconfigurable system. Network topologies are first categorized into OCR setting groups via clustering analysis. A nonparametric probability model is developed to evaluate the probability of network topologies at a measured load flow. Then, a machine learning model deployed in a local controller selects the correct setting groups based on the calculated probabilities. The proposed APS achieves high accuracies and low OCR operating times in the IEEE 33-bus test distribution system under varying load conditions and network topologies.

19 October 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MKMuthu Kumaran
Muthu Kumaran
Md HasanuzzamanMd Hasanuzzaman
Md Hasanuzzaman
CTChia Kwang Tan
Chia Kwang Tan
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
VPVignes Ponniah
Vignes Ponniah
Commercial buildings in Malaysia contribute to 35% of the total electricity demand. During the recent COVID-19 pandemic, the global economy faced a challenging situation that forced many businesses to shut down. However, fast-food restaurants with drive-through features managed to get through this pandemic phase without much effect from the economic impact. Since COVID-19, the operational guidelines have changed for restaurants. However, from an energy perspective, fast–food restaurants are high energy consumers in the retail sector. This paper analyses the load profile of fast-food restaurants and the potential strategies that can be adopted in a free-standing fast-food restaurant. From analysis, it is calculated that a total of RM 97,365.9 of utility savings can be obtained in a year. A total of 91,392.1 kg CO2, 881.8 kg SO2 and 385.5 kg CO pollutant emissions can be reduced. The BEI for the restaurant was reduced to 856.4 kWh/m2/year. By converting to energy-saving strategies, the return on investment was 27.3% and 3.7 years, which is a very short period of time and is attractive for businesses of this nature.