Ab Halim Abu Bakar

Prof. Ab Halim Abu Bakar


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
MAMohd Syukri Ali
Mohd Syukri Ali
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
AOAzimah Omar
Azimah Omar
AJAmirul Syafiq Abdul Jaafar
Amirul Syafiq Abdul Jaafar
SMSiti Hajar Mohamed
Siti Hajar Mohamed

10 February 2022 in Current Opinion in Chemical Engineering
Verified
Journal Article
Closed access
ASAmirul Syafiq
Amirul Syafiq
VBVengadaesvaran Balakrishnan
Vengadaesvaran Balakrishnan
MAMohd Syukri Ali
Mohd Syukri Ali
SDSanjay J Dhoble
Sanjay J Dhoble
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
ABAb Halim Abu Bakar
Ab Halim Abu Bakar

1 January 2014 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
MAMuhammad Mohsin Aman
Muhammad Mohsin Aman
GJG.B. Jasmon
G.B. Jasmon
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis

14 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
MNMohamad Norshahrani
Mohamad Norshahrani
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
JJJ.J. Jamian
J.J. Jamian
SSShivashankar Sukumar
Shivashankar Sukumar
The benefits of distributed generation (DG) based on renewable energy sources leads to its high integration in the distribution network (DN). Despite its well-known benefits, mainly in improving the distribution system reliability and security, there are challenges encountered from a protection system perspective. Traditionally, the design and operation of the protection system are based on a unidirectional power flow in the distribution network. However, the integration of distributed generation causes multidirectional power flows in the system. Therefore, the existing protection systems require some improvement or modification to address this new feature. Various protection strategies for distribution system have been proposed so that the benefits of distributed generation can be fully utilized. This paper reviews the current progress in protection strategies to mitigate the impact of distributed generation in the distribution network. In general, the reviewed strategies in this paper are divided into: (1) conventional protection systems and (2) modifications of the protection systems. A comparative study is presented in terms of the respective benefits, shortcomings and implementation cost. Future directions for research in this area are also presented.

23 June 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HIHazlee Azil Illias
Hazlee Azil Illias
XCXin Chai
Xin Chai
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
It is important to predict the incipient fault in transformer oil accurately so that the maintenance of transformer oil can be performed correctly, reducing the cost of maintenance and minimise the error. Dissolved gas analysis (DGA) has been widely used to predict the incipient fault in power transformers. However, sometimes the existing DGA methods yield inaccurate prediction of the incipient fault in transformer oil because each method is only suitable for certain conditions. Many previous works have reported on the use of intelligence methods to predict the transformer faults. However, it is believed that the accuracy of the previously proposed methods can still be improved. Since artificial neural network (ANN) and particle swarm optimisation (PSO) techniques have never been used in the previously reported work, this work proposes a combination of ANN and various PSO techniques to predict the transformer incipient fault. The advantages of PSO are simplicity and easy implementation. The effectiveness of various PSO techniques in combination with ANN is validated by comparison with the results from the actual fault diagnosis, an existing diagnosis method and ANN alone. Comparison of the results from the proposed methods with the previously reported work was also performed to show the improvement of the proposed methods. It was found that the proposed ANN-Evolutionary PSO method yields the highest percentage of correct identification for transformer fault type than the existing diagnosis method and previously reported works.

9 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
NLNURUL AIN ABDUL LATIFF
NURUL AIN ABDUL LATIFF
HIHazlee Azil Illias
Hazlee Azil Illias
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
SDSAMEH DABBAK
SAMEH DABBAK
In zinc oxide (ZnO) surge arresters, leakage current usually flows across the arrester under normal operating condition. Leakage current is one of the factors which contribute towards degradation of surge arresters and therefore, it is very important to monitor the condition of surge arrester. In this work, the behaviour of leakage current in a ZnO surge arrester during normal operation, under different voltage amplitudes, wetness and pollution conditions was analysed. An 11 kV surge arrester model in three-dimensional space was subjected to finite element analysis (FEA) to determine the leakage current under different conditions. The results from the FEA model were compared with the measurement results to validate the model that has been developed. From comparison between the measurement and simulation results, physical parameters of a surge arrester that influence the leakage current under different conditions of the surge arrester were identified from the model. Through this work, a better understanding of leakage current behaviour can be attained, which may help in condition monitoring analysis on surge arrester in electrical utilities.