9 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
Ayman Al-QuraanAyman Al-Quraan
Ayman Al-Quraan
MAMuhannad Al-Qaisi
Muhannad Al-Qaisi
The problem of electrical power delivery is a common problem, especially in remote areas where electrical networks are difficult to reach. One of the ways that is used to overcome this problem is the use of networks separated from the electrical system through which it is possible to supply electrical energy to remote areas. These networks are called standalone microgrid systems. In this paper, a standalone micro-grid system consisting of a Photovoltaic (PV) and Wind Energy Conversion System (WECS) based Permanent Magnet Synchronous Generator (PMSG) is being designed and controlled. Fuzzy logic-based Maximum Power Point Tracking (MPPT) is being applied to a boost converter to control and extract the maximum power available for the PV system. The control system is designed to deliver the required energy to a specific load, in all scenarios. The excess energy generated by the PV panel is used to charge the batteries when the energy generated by the PV panel exceeds the energy required by the load. When the electricity generated by the PV panels is insufficient to meet the load’s demands, the extra power is extracted from the charged batteries. In addition, the controller protects the battery banks in all conditions, including normal, overcharging, and overdischarging conditions. The controller should handle each case correctly. Under normal operation conditions (20% < State of Charge (SOC) < 80%), the controller functions as expected, regardless of the battery’s state of charge. When the SOC reaches 80%, a specific command is delivered, which shuts off the PV panel and the wind turbine. The PV panel and wind turbine cannot be connected until the SOC falls below a safe margin value of 75% in this controller. When the SOC goes below 20%, other commands are sent out to turn off the inverter and disconnect the loads. The electricity to the inverter is turned off until the batteries are charged again to a suitable value.

3 December 2023 in Energy Conversion and Management
Verified
Journal Article
Closed access
Ayman Al-QuraanAyman Al-Quraan
Ayman Al-Quraan
BABashar Fayez Al-Mhairat
Bashar Fayez Al-Mhairat

28 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
QSQusay Salem
Qusay Salem
RARafat Aljarrah
Rafat Aljarrah
Mazaher KarimiMazaher Karimi
Mazaher Karimi
Ayman Al-QuraanAyman Al-Quraan
Ayman Al-Quraan
Grid-forming inverters are anticipated to be integrated more into future smart microgrids commencing the function of traditional power generators. The grid-forming inverter can generate a reference frequency and voltage itself without assistance from the main grid. This paper comprehensively investigates grid-forming inverter modelling and control methodology. A decentralized method employing an active power versus frequency P − f droop and a reactive power versus voltage Q − V droop is exploited to drive the operation of the grid-forming inverter. This decentralized method ensures balancing the supply and demand beside the power-sharing task between two or more inverters. The performance of the grid-forming inverter is examined by monitoring the frequency and RMS voltage of the inverter bus for three different periods of a varying PQ load. In addition, the performance of the resultant droop is compared with the assumed droop to validate the effectiveness of the proposed method. Finally, two grid-forming inverters equipped with the same droop characteristics are connected to a single load to observe the power-sharing concept among them. All simulations are implemented and executed using Matlab/Simulink version R2014b.

17 May 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Ayman Al-QuraanAyman Al-Quraan
Ayman Al-Quraan
MAMOHAMMED AL-MAHMODI
MOHAMMED AL-MAHMODI
KAKhaled Alzaareer
Khaled Alzaareer
Claude El-BayehClaude El-Bayeh
Claude El-Bayeh
Ursula EickerUrsula Eicker
Ursula Eicker
In mounted photovoltaic (PV) facilities, energy output losses due to inter-row shading are unavoidable. In order to limit the shadow cast by one module row on another, sufficient inter-row space must be planned. However, it is not uncommon to see PV plants with such close row spacing that energy losses occur owing to row-to-row shading effects. Low module prices and high ground costs lead to such configurations, so the maximum energy output per available surface area is prioritized over optimum energy production per peak power. For any applications where the plant power output needs to be calculated, an exact analysis of the influence of inter-row shading on power generation is required. In this paper, an effective methodology is proposed and discussed in detail, ultimately, to enable PV system designers to identify the optimal inter-row spacing between arrays by generating a multiplier factor. The spacing multiplier factor is mathematically formulated and is generated to be a general formula for any geographical location including flat and non-flat terrains. The developed model is implemented using two case studies with two different terrains, to provide a wider context. The first one is in the Kingdome of Saudi Arabia (KSA) provinces, giving a flat terrain case study; the inter-row spacing multiplier factor is estimated for the direct use of a systems designer. The second one is the water pump for agricultural watering using renewable energy sources, giving a non-flat terrain case study in Dhamar, Al-Hada, Yemen. In this case study, the optimal inter-row spacing factor is estimated for limited-area applications. Therefore, the effective area using the proposed formula is minimized so that the shading of PV arrays on each other is avoided, with a simple design using the spacing factor methodology.

6 October 2021 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
ARAshraf Radaideh
Ashraf Radaideh
MBMu’mEn Bodoor
Mu’mEn Bodoor
Ayman Al-QuraanAyman Al-Quraan
Ayman Al-Quraan
This paper proposes an optimal gain-scheduling for linear quadratic regulator (LQR) control framework to improve the performance of wind turbines based Doubly Fed Induction Generator (DFIG). Active and reactive power decoupling is performed using the field-oriented vector control which is used to simplify DFIG’s nonlinearity and derive a compact linearized state-space model. The performance of the optimal controller represented by a linear quadratic regulator is further enhanced using the whale optimization algorithm in a multiobjective optimization environment. Adaptiveness against wind speed variation is achieved in an offline training process at a discretized wind speed domain. Lookup tables are used to store the optimal controller parameter and called upon during the online implementation. The control framework further integrates the effects of pitch angle control mechanism for active power ancillary services and possible improvements on reactive power support. The results of the proposed control framework improve the overall performance of the system compared to the conventional PI controller. Comparison is performed using the MATLAB Simulink platform.