Yongbin Qi

Mr. Yongbin Qi


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2014 in Sensors
Verified
Journal Article
Open access
PDF file
YQYongbin Qi
Yongbin Qi
CSCheong Boon Soh
Cheong Boon Soh
EGErry Gunawan
Erry Gunawan
KLKay-Soon Low
Kay-Soon Low
RTRijil Thomas
Rijil Thomas
In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications.

23 April 2015 in Sensors
Verified
Journal Article
Open access
PDF file
YQYongbin Qi
Yongbin Qi
CSCheong Boon Soh
Cheong Boon Soh
EGErry Gunawan
Erry Gunawan
KLKay-Soon Low
Kay-Soon Low
RTRijil Thomas
Rijil Thomas
This paper presents an unrestrained measurement system based on a wearable wireless ultrasonic sensor network to track the lower extremity joint and trunk kinematics during a squat exercise with only one ultrasonic sensor attached to the trunk. The system consists of an ultrasound transmitter (mobile) and multiple receivers (anchors) whose positions are known. The proposed system measures the horizontal and vertical displacement, together with known joint constraints, to estimate joint flexion/extension angles using an inverse kinematic model based on the damped least-squares technique. The performance of the proposed ultrasonic measurement system was validated against a camera-based tracking system on eight healthy subjects performing a planar squat exercise. Joint angles estimated from the ultrasonic system showed a root mean square error (RMSE) of 2.85° ± 0.57° with the reference system. Statistical analysis indicated great agreements between these two systems with a Pearson’s correlation coefficient (PCC) value larger than 0.99 for all joint angles’ estimation. These results show that the proposed ultrasonic measurement system is useful for applications, such as rehabilitation and sports.