This paper presents a new highly accurate gait phase detection system using wearable wireless ultrasonic sensors, which can be used in gait analysis or rehabilitation applications. The gait phase detection system uses the foot displacement information during walking to extract the following gait phases: heel-strike, heel-off, toe-off, and mid-swing. The displacement of foot-mounted ultrasonic sensor is obtained from several passive anchors placed at known locations by employing local spherical positioning technique, which is further enhanced by the combination of recursive Newton-Gauss method and Kalman Filter. The algorithm performance is examined by comparing with a commercial optical motion tracking system with ten healthy subjects and two foot injured subjects. Accurate estimates of gait cycle (with an error of -0.02 ±0.01 s), stance phase(with an error of 0.04±0.03 s), and swing phase (with an error of -0.05±0.03 s) compared to the reference system are obtained. We have also investigated the influence of walking velocities on the performance of the proposed gait phase detection algorithm. Statistical analysis shows that there is no significant difference between both systems during different walking speeds. Moreover, we have tested and discussed the possibility of the proposed system for clinical applications by analyzing the experimental results for both healthy and injured subjects. The experiments show that the estimated gait phases have the potential to become indicators for sports and rehabilitation engineering.
In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications.
This paper presents an unrestrained measurement system based on a wearable wireless ultrasonic sensor network to track the lower extremity joint and trunk kinematics during a squat exercise with only one ultrasonic sensor attached to the trunk. The system consists of an ultrasound transmitter (mobile) and multiple receivers (anchors) whose positions are known. The proposed system measures the horizontal and vertical displacement, together with known joint constraints, to estimate joint flexion/extension angles using an inverse kinematic model based on the damped least-squares technique. The performance of the proposed ultrasonic measurement system was validated against a camera-based tracking system on eight healthy subjects performing a planar squat exercise. Joint angles estimated from the ultrasonic system showed a root mean square error (RMSE) of 2.85° ± 0.57° with the reference system. Statistical analysis indicated great agreements between these two systems with a Pearson’s correlation coefficient (PCC) value larger than 0.99 for all joint angles’ estimation. These results show that the proposed ultrasonic measurement system is useful for applications, such as rehabilitation and sports.
18 October 2016 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
In order to assist cardiac diagnosis by phonocardiography, the automated identification of fundamental heart sounds for heart beat segmentation in a cardiac cycle plays a significant role in signal processing. Recent advancements in signal processing have also shown the potential of multifractality in biomedical applications. Hence, in this paper, the multifractal property of heart sounds is utilized to identify first and second heart sounds. The root mean square (rms) fluctuation used to obtain multifractal/singularity spectrum is used to decompose the heart sound into its own fractally-important components in time domain along with simultaneous Gaussianity test to filter out fundamental components. The performance is evaluated on an experimental database of 23 different heart sounds and 6 patients' recordings done in a real clinical environment. Simulation results have shown that it is a promising approach in Heart Sound Segmentation (HSS).
17 May 2016 in The Journal of Physical Chemistry C