The state of the energy-absorption branch MOV in the hybrid DC circuit breaker (DCCB) has a very important impact on the short fault breaking operation of the circuit breaker. Therefore, it is necessary to evaluate the state of the MOV, which is also called the “sleep component”. Due to DCCB being placed indoors, the aging is mainly caused by short-circuit impulse current. Therefore, this paper mainly focuses on the study of the short-circuit impulse aging characteristics of the energy-absorption branch MOV. The dynamic simulation system of a hybrid DCCB was built to investigate the impulse of short-circuit current on the MOV of the energy-absorption branch during the circuit breaking process. Then, an accelerated impulse aging test platform was built and the accelerated impulse aging tests of the MOV were conducted. The aging characteristics of the MOV were analyzed in detail and detailed analysis was conducted of the macroscopic parameters and microstructure changes. The results indicate that the nonlinear coefficient α could be emphasized as a basis for judging the “sleeping” component states and aging degree of the hybrid DC circuit breaker, and can be expected to be applicable to MOV condition monitoring of BCCB in the future.
Due to the initial defects, partial discharge (PD) will occur in the transformer, which will further deteriorate the internal insulation of the transformer and even the breakdown of the insulation system. Therefore, it is of great significance to accurately locate the PD in the transformer. At present, The piezoelectric sensor is widely used in PD ultrasonic localization. However, coupling optical fiber ultrasonic sensor (COFUS) is a good alternative for its strong anti-electromagnetic interference ability, low material cost and small structure. In this paper, an experimental system based on COFUS is proposed, and the localization algorithm is determined. Finally, the experiments of acoustic-acoustic localization and electro-acoustic localization are carried out. The results show that the average geometric errors are 54.14 mm and 45.14 mm respectively. That is, the localization results have high localization accuracy. Therefore, the COFUS has a broad application prospect in PD localization of transformer.
The current prefabricated steel structure residences had the problems of complex structure and inflexible layout, which limited the development of prefabricated steel structure. In order to solve the problem of exposed columns in prefabricated steel structure residence, a new L-shaped Steel Lattice Column (L-SSLC) was proposed. A simplified formula for ultimate bearing capacity of L-SSLC was produced by double coefficient multiplication method. The nonlinear finite element analysis of L-SSLC was performed using ABAQUS software, in which the compression performance was analysed. Theoretical results calculated by simplified formula were compared to that of the finite element analysis. The results indicate that the stress at the connection between batten plates and steel pipes is relatively large. Compared to axial compression columns, eccentric compression columns have better ductility and lower bearing capacity. The simplified formula is feasible and the redundancy factor is 1.12-1.41.