Yiying Liu

Dr. Yiying Liu

School of Electrical Engineering, Xi'an Jiaotong University, Xian, 710049, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2023 in Measurement
Verified
Journal Article
Closed access
WFWencheng Fu
Wencheng Fu
Yiying LiuYiying Liu
Yiying Liu
LWLinjie Wang
Linjie Wang
XWXuhong Wang
Xuhong Wang

29 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XWXinyi Wang
Xinyi Wang
Yiying LiuYiying Liu
Yiying Liu
YLYilei Lv
Yilei Lv
JSJinru Sun
Jinru Sun
XYXueling Yao
Xueling Yao
ZLZhihan Li
Zhihan Li
The state of the energy-absorption branch MOV in the hybrid DC circuit breaker (DCCB) has a very important impact on the short fault breaking operation of the circuit breaker. Therefore, it is necessary to evaluate the state of the MOV, which is also called the “sleep component”. Due to DCCB being placed indoors, the aging is mainly caused by short-circuit impulse current. Therefore, this paper mainly focuses on the study of the short-circuit impulse aging characteristics of the energy-absorption branch MOV. The dynamic simulation system of a hybrid DCCB was built to investigate the impulse of short-circuit current on the MOV of the energy-absorption branch during the circuit breaking process. Then, an accelerated impulse aging test platform was built and the accelerated impulse aging tests of the MOV were conducted. The aging characteristics of the MOV were analyzed in detail and detailed analysis was conducted of the macroscopic parameters and microstructure changes. The results indicate that the nonlinear coefficient α could be emphasized as a basis for judging the “sleeping” component states and aging degree of the hybrid DC circuit breaker, and can be expected to be applicable to MOV condition monitoring of BCCB in the future.

21 October 2021
Verified
Conference Paper
Closed access
PYPenghui Yang
Penghui Yang
Yiying LiuYiying Liu
Yiying Liu
PYPenghao Yu
Penghao Yu
XWXuhong Wang
Xuhong Wang
NWNa Wang
Na Wang
Due to the initial defects, partial discharge (PD) will occur in the transformer, which will further deteriorate the internal insulation of the transformer and even the breakdown of the insulation system. Therefore, it is of great significance to accurately locate the PD in the transformer. At present, The piezoelectric sensor is widely used in PD ultrasonic localization. However, coupling optical fiber ultrasonic sensor (COFUS) is a good alternative for its strong anti-electromagnetic interference ability, low material cost and small structure. In this paper, an experimental system based on COFUS is proposed, and the localization algorithm is determined. Finally, the experiments of acoustic-acoustic localization and electro-acoustic localization are carried out. The results show that the average geometric errors are 54.14 mm and 45.14 mm respectively. That is, the localization results have high localization accuracy. Therefore, the COFUS has a broad application prospect in PD localization of transformer.

6 November 2021
Verified
Conference Paper
Closed access
Yiying LiuYiying Liu
Yiying Liu
XFXiaoFan Fu
XiaoFan Fu
XPXiaoTong Peng
XiaoTong Peng
LCLin Chen
Lin Chen
The current prefabricated steel structure residences had the problems of complex structure and inflexible layout, which limited the development of prefabricated steel structure. In order to solve the problem of exposed columns in prefabricated steel structure residence, a new L-shaped Steel Lattice Column (L-SSLC) was proposed. A simplified formula for ultimate bearing capacity of L-SSLC was produced by double coefficient multiplication method. The nonlinear finite element analysis of L-SSLC was performed using ABAQUS software, in which the compression performance was analysed. Theoretical results calculated by simplified formula were compared to that of the finite element analysis. The results indicate that the stress at the connection between batten plates and steel pipes is relatively large. Compared to axial compression columns, eccentric compression columns have better ductility and lower bearing capacity. The simplified formula is feasible and the redundancy factor is 1.12-1.41.