Objective. The purpose of this pilot study was to evaluate the long-term clinical performance of implant-supported full-arch zirconia-based fixed dental prostheses (FDPs). Materials and methods. Ten patients received full-arch zirconia-based (Cercon) mandibular FDPs supported by four implants (Astra Tech). Nine patients received 10-unit FDPs and one patient received a 9-unit FDP. The FDPs were cemented onto individually prepared titanium abutments and were evaluated at baseline and after 12, 24, 36 and 96 months. Results. Nine patients attended the 8-year follow-up. None of the restorations showed bulk fracture, all FDPs were in use. Fractures of the veneering porcelain were, however, observed in eight patients. A total of 36 out of 89 units (40%) showed such fractures. Patient satisfaction was excellent despite the veneering material fractures. Conclusion. Results from this 8-year pilot study suggest that implant-supported full-arch zirconia-based FDPs can be an acceptable treatment alternative.
1 July 2017 in The Journal of Prosthetic Dentistry
(1) Background: This paper aimed to compare the cleanliness of clinically well-documented implant systems with implants providing very similar designs. The hypothesis was that three well-established implant systems from Dentsply Implants, Straumann, and Nobel Biocare were not only produced with a higher level of surface cleanliness but also provided significantly more comprehensive published clinical documentation than their correspondent look-alike implants from Cumdente, Bioconcept, and Biodenta, which show similar geometry and surface structure. (2) Methods: Implants were analyzed using SEM imaging and energy-dispersive X-ray spectroscopy to determine the elemental composition of potential impurities. A search for clinical trials was carried out in the PubMed database and by reaching out to the corresponding manufacturer. (3) Results: In comparison to their corresponding look-alikes, all implants of the original manufacturers showed—within the scope of this analysis—a surface free of foreign materials and reliable clinical documentation, while the SEM analysis revealed significant impurities on all look-alike implants such as organic residues and unintended metal particles of iron or aluminum. Other than case reports, the look-alike implant manufacturers provided no reports of clinical documentation. (4) Conclusions: In contrast to the original implants of market-leading manufacturers, the analyzed look-alike implants showed significant impurities, underlining the need for periodic reviews of sterile packaged medical devices and their clinical documentation.