Agne Gedrimiene

Agne Gedrimiene

Auto-generated profile, based on publicly available information

Agne Gedrimiene

Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2021 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PDF file
VRVygandas Rutkunas
Vygandas Rutkunas
AGAgne Gedrimiene
Agne Gedrimiene
MAMykolas Akulauskas
Mykolas Akulauskas
VFVincent Fehmer
Vincent Fehmer
ISIrena Sailer
Irena Sailer
DJDarius Jegelevičius
Darius Jegelevičius
Objectives The main objective of the study was to compare the accuracy of full-arch digital implant impressions for fixed dental prosthesis under in vitro and in vivo conditions. Material and Methods Eight patients (5 women and 3 men) with at least one edentulous arch and with 4-6 osseointegrated implants participated in this study. For each edentulous arch (n=10) experimental screw-retained titanium bar with attached 4 scan bodies was fabricated. The bar containing 4 scan bodies was screw-retained intraorally on implants and scanned with Trios 3 intraoral scanner 8 times (IOS group, in vivo). Then the bar was attached to the master cast and scanned 8 times again with the same intraoral scanner (MIOS group, in vitro). Finally, the bar with scan bodies was scanned 8 times with a laboratory scanner (reference). Precision and trueness were calculated for 3 distances and 3 angles between the scan bodies (1-2, 1-3, and 1-4) in IOS and MIOS groups. Results Precision and trueness for the largest distance (1-4) were found to be 44±18 µm and 32±19 µm for the IOS group, and 31±16 µm and 30±14µm for MIOS group, respectively. Precision and trueness for the angle between the most distant scan bodies (1-4) were 0.22±0.14° and 0.18±0.10° for the IOS group, and 0.16±0.11° and 0.07±0.05° for MIOS group, respectively. Conclusions Intraoral conditions moderately affected the precision and trueness of Trios 3 (3Shape) intraoral scanner. Results of in vitro accuracy studies cannot be directly transferred to the clinical field.

1 January 2019 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
AGAgne Gedrimiene
Agne Gedrimiene
Rimas AdaškevičiusRimas Adaškevičius
Rimas Adaškevičius
VRVygandas Rutkunas
Vygandas Rutkunas
Gedrimiene A, et al. J Adv Prosthodont. 2019 Oct;11(5):271-279. https://doi.org/10.4047/jap.2019.11.5.271

5 February 2020 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
VRVygandas Rutkunas
Vygandas Rutkunas
CLChristel Larsson
Christel Larsson
PSPer Vult von Steyern
Per Vult von Steyern
FMFrancesco Mangano
Francesco Mangano
AGAgne Gedrimiene
Agne Gedrimiene

21 March 2022 in Journal of Prosthodontics
Verified
Journal Article
Closed access
VRVygandas Rutkūnas
Vygandas Rutkūnas
AGAgnė Gedrimienė
Agnė Gedrimienė
LALiudas Auškalnis
Liudas Auškalnis
OAOleg Admakin
Oleg Admakin
FMFrancesco Mangano
Francesco Mangano

1 January 2024 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
VRVygandas Rutkunas
Vygandas Rutkunas
DJDarius Jegelevičius
Darius Jegelevičius
JPJustinas Pletkus
Justinas Pletkus
LALiudas Auškalnis
Liudas Auškalnis
MAMykolas Akulauskas
Mykolas Akulauskas
AGAgnė Gedrimienė
Agnė Gedrimienė
Rutkūnas V, et al. J Adv Prosthodont. 2024 Oct;16(5):302-310. https://doi.org/10.4047/jap.2024.16.5.302

1 January 2021
Verified
Journal Article
Closed access
VRVygandas Rutkunas
Vygandas Rutkunas
AGAgne Gedrimiene
Agne Gedrimiene
RJReinhilde Jacobs
Reinhilde Jacobs
MMMangirdas Malinauskas
Mangirdas Malinauskas