Aggregation states of amyloid beta peptides for amyloid beta A to A and A p are investigated through small angle neutron scattering (SANS). The knowledge of these small peptides and their aggregation state are of key importance for the comprehension of neurodegenerative diseases (e.g., Alzheimer’s disease). The SANS technique allows to study the size and fractal nature of the monomers, oligomers and fibrils of the three different peptides. Results show that all the investigated peptides have monomers with a radius of gyration of the order of 10 Å, while the oligomers and fibrils display differences in size and aggregation ability, with A p showing larger oligomers. These properties are strictly related to the toxicity of the corresponding amyloid peptide and indeed to the development of the associated disease.
Achieved spatial resolution of the PET systems is often limited by the parallax error due to the lack of information about the Depth of Interaction (DoI) inside the crystal of the incoming 511 keV annihilation photons. The smaller the diameter of the PET ring and the thicker the scintillator are, the more this error affects imaging performance. In this work, a DoI calculator suitable for monolithic scintillation crystals and based on the shape of the scintillation light distribution at the photodetector surface has been proposed. To test the estimator performance, a test PET module with a 50 × 50 × 20 mm monolithic LYSO crystal coupled to a 12 × 12 SiPM array has been employed. In addition, for calibration and validation of the method, Geant4 simulations have been also used. The key result of the application of the proposed DoI estimator is obtaining a continuous DoI estimation with an average DoI resolution of about 5 mm in the 20 mm-thick crystal. Benefiting from the DoI estimation capabilities of the method, it has been also possible to achieve additional important goals, first of all reducing the parallax error. First, because the scintillation light collection varies as a function of the 3D position of the interaction of the annihilation photon inside the crystal, a method to correct this response variation via a proper 3D look-up-table is proposed. This has led to an improvement of about 35% in energy resolution. Moreover, a DoI-dependent position algorithm has been proposed, allowing an improvement of both planar (X-Y) position linearity and planar spatial resolution. This algorithm is specifically developed for the rows/columns multi-channel readout logic, that reduces the number of independent channels from N × N to N + N, where N is the number of SiPM photodetection elements (12 in our case) in each row and column. This development was performed in the framework of the MindView PET/MilI brain imaging project.
The increasing interest in stretchable conductive composite materials, that can be versatile and suitable for wide-ranging application, has sparked a growing demand for studies of scalable fabrication techniques and specifically tailored geometries. Thanks to the combination of the conductivity and robustness of carbon nanotube (CNT) materials with the viscoelastic properties of polymer films, in particular their stretchability, “surface composites” made of a CNT on polymeric films are a promising way to obtain a low-cost, conductive, elastic, moldable, and patternable material. The use of polymers selected for specific applications, however, requires targeted studies to deeply understand the interface interactions between a CNT and the surface of such polymer films, and in particular the stability and durability of a CNT grafting onto the polymer itself. Here, we present an investigation of the interface properties for a selected group of polymer film substrates with different viscoelastic properties by means of a series of different and complementary experimental techniques. Specifically, we studied the interaction of a single-wall carbon nanotube (SWCNT) deposited on two couples of different polymeric substrates, each one chosen as representative of thermoplastic polymers (i.e., low-density polyethylene (LDPE) and polypropylene (PP)) and thermosetting elastomers (i.e., polyisoprene (PI) and polydimethylsiloxane (PDMS)), respectively. Our results demonstrate that the characteristics of the interface significantly differ for the two classes of polymers with a deeper penetration (up to about 100 μm) into the polymer bulk for the thermosetting substrates. Consequently, the resistance per unit length varies in different ranges, from 1–10 kΩ/cm for typical thermoplastic composite devices (30 μm thick and 2 mm wide) to 0.5–3 MΩ/cm for typical thermosetting elastomer devices (150 μm thick and 2 mm wide). For these reasons, the composites show the different mechanical and electrical responses, therefore suggesting different areas of application of the devices based on such materials.
1 September 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment