Volodymyr Tkachenko

Dr. Volodymyr Tkachenko

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2017 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
MRMassimo Rippa
Massimo Rippa
RCRiccardo Castagna
Riccardo Castagna
VTVolodymyr Tkachenko
Volodymyr Tkachenko
JZJ. Zhou
J. Zhou
LPL. Petti
L. Petti
A fast and easy method to fabricate a novel engineered plasmonic nanoassay for protein detection in extremely low concentrations is presented.

1 August 2021 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
VFVincenzo Ferraro
Vincenzo Ferraro
MVMassimiliano M. Villone
Massimiliano M. Villone
VTVolodymyr Tkachenko
Volodymyr Tkachenko
LMLisa Miccio
Lisa Miccio
LLLorenzo Lombardi
Lorenzo Lombardi
PMPier Luca Maffettone
Pier Luca Maffettone

24 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RRROMINA REGA
ROMINA REGA
MMMartina Mugnano
Martina Mugnano
EOEmilia Oleandro
Emilia Oleandro
VTVolodymyr Tkachenko
Volodymyr Tkachenko
DGdanila del giudice
danila del giudice
SGSebastiano Gangemi
Sebastiano Gangemi
The demand for sensors capable of measuring low-abundant collagen in human fluids has highly increased in recent years. Indeed, collagen is expected to be a biomarker for chronic diseases and could monitor their progression. Here we show detection of highly diluted samples of collagen at picogram level thanks to an innovative pyro-electrohydrodynamic jet (p-jet) system. Through the intense electric fields generated by the pyroelectric effect in a ferroelectric crystal, the collagen solution was concentrated on a small area of a slide that was appropriately functionalized to bind proteins. The collagen molecules were labeled by an appropriate fluorophore to show how the number of tiny droplets influences the limit of detection of the technique. The results show that the p-jet is extremely promising for overcoming the current detection limits of collagen-based products in human fluids, performing 10 times better than the enzyme-linked immunosorbent assay (ELISA) and thus paving the way for the early diagnosis of related chronic diseases.

21 March 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
CNConcetta Di Natale
Concetta Di Natale
SCSara Coppola
Sara Coppola
VVVeronica Vespini
Veronica Vespini
VTVolodymyr Tkachenko
Volodymyr Tkachenko
SRSimone Russo
Simone Russo
SGSimonetta Grilli
Simonetta Grilli
It is largely documented that neurodegenerative diseases can be effectively treated only if early diagnosed. In this context, the structural changes of some biomolecules such as Tau, seem to play a key role in neurodegeneration mechanism becoming eligible targets for an early diagnosis. Post-translational modifications are responsible to drive the Tau protein towards a transition phase from a native disorder conformation into a preaggregation state, which then straight recruits the final fibrillization process. Here, we show for the first time the detection of pre-aggregated Tau in artificial urine at femto-molar level, through the concentration effect of the pyro-electrohydrodynamic jet (p-jet) technique. An excellent linear calibration curve is demonstrated at the femto-molar level with a limit of detection (LOD) of 130 fM. Moreover, for the first time we show here the structure stability of the protein after p-jet application through a deep spectroscopic investigation. Thanks to the small volumes required and the relatively compact and cost-effective characteristics, this technique represents an innovative breakthrough in monitoring the early stage associated to neurodegeneration syndromes in different scenarios of point of care (POC) and such as for example in long-term human space exploration missions.

10 July 2021 in Advanced Engineering Materials
Verified
Journal Article
Closed access
PDF file
VTVolodymyr Tkachenko
Volodymyr Tkachenko
RSReinhard Schwödiauer
Reinhard Schwödiauer
RRROMINA REGA
ROMINA REGA
SISimona Itri
Simona Itri
MMMartina Mugnano
Martina Mugnano
SGSimonetta Grilli
Simonetta Grilli

27 November 2006 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
VTVolodymyr Tkachenko
Volodymyr Tkachenko
GAG. Abbate
G. Abbate
AMA. Marino
A. Marino
Francesco VitaFrancesco Vita
Francesco Vita
MGMichele Giocondo
Michele Giocondo
Luca De StefanoLuca De Stefano
Luca De Stefano
The design and fabrication of active and passive hybrid photonic devices, with tunable optical properties, based on liquid crystals require a very accurate knowledge of their anisotropic refractive indices up to 100ppm in the wavelength region of interest. At this aim, the authors have integrated two standard optical techniques commonly used in liquid crystals characterization, the variable angle spectroscopic ellipsometry and the half leaky guided mode spectroscopy, exploiting their best performances and overcoming their limits. The dispersion curves of nematic liquid crystal E7 have been estimated in the 450–1700nm wavelength interval with both precision and accuracy of 10−4 .