Joanna Cabaj

Dr. Joanna Cabaj

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
KHKinga Halicka-Stępień
Kinga Halicka-Stępień
JCJoanna Cabaj
Joanna Cabaj
Sensors and biosensors have found applications in many areas, e.g., in medicine and clinical diagnostics, or in environmental monitoring. To expand this field, nanotechnology has been employed in the construction of sensing platforms. Because of their properties, such as high surface area to volume ratio, nanofibers (NFs) have been studied and used to develop sensors with higher loading capacity, better sensitivity, and faster response time. They also allow to miniaturize designed platforms. One of the most commonly used techniques of the fabrication of NFs is electrospinning. Electrospun NFs can be used in different types of sensors and biosensors. This review presents recent studies concerning electrospun nanofiber-based electrochemical and optical sensing platforms for the detection of various medically and environmentally relevant compounds, including glucose, drugs, microorganisms, and toxic metal ions.

5 September 2022 in RSC Advances
Verified
Journal Article
Open access
PDF file
Sylwia BalutaSylwia Baluta
Sylwia Baluta
FMFrancesca Meloni
Francesca Meloni
KHKinga Halicka-Stępień
Kinga Halicka-Stępień
ASAdam Szyszka
Adam Szyszka
Antonio ZuccaAntonio Zucca
Antonio Zucca
JCJoanna Cabaj
Joanna Cabaj
The main goal of the presented study was to design a biosensor-based system for epinephrine (EP) detection using a poly-thiophene derivative and tyrosinase as a biorecognition element. We compared two different electroanalytical techniques to select the most prominent technique for analyzing the neurotransmitter. The prepared biosensor system exhibited good parameters; the differential pulse (DPV) technique presented a wide linear range (1–20 μM and 30–200 μM), with a low detection limit (0.18 nM and 1.03 nM). In the case of chronoamperometry (CA), a high signal-to-noise ratio and lower reproducibility were observed, causing a less broad linear range (10–200 μM) and a higher detection limit (125 nM). Therefore, the DPV technique was used for the calculation of sensitivity (0.0011 μA mM−1 cm−2), stability (49 days), and total surface coverage (4.18 × 10−12 mol cm−2). The biosensor also showed very high selectivity in the presence of common interfering species (i.e. ascorbic acid, uric acid, norepinephrine, dopamine) and was successfully applied for EP determination in a pharmaceutical sample.

2 February 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ALAnna Lesiak
Anna Lesiak
KDKamila Drzozga
Kamila Drzozga
JCJoanna Cabaj
Joanna Cabaj
MBMateusz Banski
Mateusz Banski
KMKarol Malecha
Karol Malecha
APArtur Podhorodecki
Artur Podhorodecki
Fundamentals of quantum dots (QDs) sensing phenomena show the predominance of these fluorophores over standard organic dyes, mainly because of their unique optical properties such as sharp and tunable emission spectra, high emission quantum yield and broad absorption. Moreover, they also indicate no photo bleaching and can be also grown as no blinking emitters. Due to these properties, QDs may be used e.g., for multiplex testing of the analyte by simultaneously detecting multiple or very weak signals. Physico-chemical mechanisms used for analyte detection, like analyte stimulated QDs aggregation, nonradiative Förster resonance energy transfer (FRET) exhibit a number of QDs, which can be applied in sensors. Quantum dots-based sensors find use in the detection of ions, organic compounds (e.g., proteins, sugars, volatile substances) as well as bacteria and viruses.

18 May 2020 in Polymers
Verified
Journal Article
Open access
PDF file
KSKamila Spychalska
Kamila Spychalska
DZDorota Zając
Dorota Zając
Sylwia BalutaSylwia Baluta
Sylwia Baluta
KHKinga Halicka-Stępień
Kinga Halicka-Stępień
JCJoanna Cabaj
Joanna Cabaj
In this review we present polymeric materials for (bio)sensor technology development. We focused on conductive polymers (conjugated microporous polymer, polymer gels), composites, molecularly imprinted polymers and their influence on the design and fabrication of bio(sensors), which in the future could act as lab-on-a-chip (LOC) devices. LOC instruments enable us to perform a wide range of analysis away from the stationary laboratory. Characterized polymeric species represent promising candidates in biosensor or sensor technology for LOC development, not only for manufacturing these devices, but also as a surface for biologically active materials’ immobilization. The presence of biological compounds can improve the sensitivity and selectivity of analytical tools, which in the case of medical diagnostics is extremely important. The described materials are biocompatible, cost-effective, flexible and are an excellent platform for the anchoring of specific compounds.

24 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
WNWitold Nawrot
Witold Nawrot
KDKamila Drzozga
Kamila Drzozga
Sylwia BalutaSylwia Baluta
Sylwia Baluta
JCJoanna Cabaj
Joanna Cabaj
KMKarol Malecha
Karol Malecha
The clinical applications of sensing tools (i.e., biosensors) for the monitoring of physiologically important analytes are very common. Nowadays, the biosensors are being increasingly used to detect physiologically important analytes in real biological samples (i.e., blood, plasma, urine, and saliva). This review focuses on biosensors that can be applied to continuous, time-resolved measurements with fluorescence. The material presents the fluorescent biosensors for the detection of neurotransmitters, hormones, and other human metabolites as glucose, lactate or uric acid. The construction of microfluidic devices based on fluorescence uses a variety of materials, fluorescent dyes, types of detectors, excitation sources, optical filters, and geometrical systems. Due to their small size, these devices can perform a full analysis. Microfluidics-based technologies have shown promising applications in several of the main laboratory techniques, including blood chemistries, immunoassays, nucleic-acid amplification tests. Of the all technologies that are used to manufacture microfluidic systems, the LTCC technique seems to be an interesting alternative. It allows easy integration of electronic and microfluidic components on a single ceramic substrate. Moreover, the LTCC material is biologically and chemically inert, and is resistant to high temperature and pressure. The combination of all these features makes the LTCC technology particularly useful for implementation of fluorescence-based detection in the ceramic microfluidic systems.

15 April 2018 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
Sylwia BalutaSylwia Baluta
Sylwia Baluta
ALAnna Lesiak
Anna Lesiak
JCJoanna Cabaj
Joanna Cabaj