Static var generator (SVG) is mostly utilized under polluted grid conditions with certain power quality problems, of which the grid disturbance will lead to the distortion of grid-side current. Hybrid repetitive controller (RC), as an effective method to suppress periodic distortion of grid-connected converters and to improve the dynamic response of conventional RC, has been adopted in existing approaches. However, the physical meaning of existing modeling based on the small gain theorem is not clear. Besides, the conventional design method is difficult to reveal the stability domain and to obtain an optimized repetitive gain, which influences the anti-disturbance performance. In this article, the coupling effect among the controllers of hybrid RC is revealed, showing clear physical meaning, thus the mechanism resulting in the instability problem and delay effect is addressed clearly. Different from existing methods, a simpler design principle is proposed, and a universal stability domain analysis for hybrid RC can be directly obtained and ensure a maximized repetitive gain. A proportional, resonant, and RC (PR-RC) is given as an example to improve the dynamic response of the SVG under $a$ – $b$ – $c$ coordinate. Experimental results demonstrate the correctness and effectiveness of the coupling analysis and parameter design.
17 May 2023 in IEEE Transactions on Industry Applications
For better utilization of DC-inherent renewable energy with high penetration and fluctuation, the solid-state transformer (SST)-based power systems have received great attention and arose increasing demand for grid supports and power management. Given the plug-and-play function of distributed renewable energy and loads, the economical and balanced power allocation as well as the flexible seamless transition among different operation modes are not considered comprehensively in existing studies. Therefore, distributed power management and adaptive coordinated control strategy are proposed for SST-interfaced power systems. 1) The application of SST as an alternative to multiple converters to interface the high-voltage grid (HG) and hybrid AC/DC microgrids (MGs) can reduce system communication. Compared with traditional transformers, the controllability and intelligence of SST-enabled power systems are improved. 2) The flexible seamless transition and adaptive coordinated control among HG-connected mode, MG interconnected mode and islanding mode are realized to adapt to different fault conditions. 3) Considering system operation limits, the economical and balanced power allocation is realized accurately, and the voltage quality is effectively ensured in various operation modes. Finally, the feasibility and effectiveness of the proposed system and control strategy are tested on the OPAL-RT-based platform.
29 August 2023 in IEEE Transactions on Power Electronics
This paper proposes a boost-type four-leg inverter for three-phase permanent magnet synchronous machine (PMSM) drives where the power supply is innovatively connected between the neutral point of the motor and the fourth leg. Due to the special connection, the zero-sequence circuit of a PMSM drive fed by the proposed four-leg inverter can not only be used to tolerate an open-phase fault (OPF) but also to boost the dc-bus voltage. According to the analytical modelling and equivalent circuit, it is revealed that the four-leg inverter based PMSM drive is similar to a two-stage drive under healthy operating conditions. When an OPF occurs, the motor can be normally operated with only two active phases. In post-fault conditions, the remaining phase-currents are not sinusoidal any more. Besides, the trajectory of the post-fault current vector is not a standard circle. The traditional field-oriented control strategy can still be adopted in the drive. However, the references of the $d$ -axis current and neutral current have to be modified by injecting specific components. A differential flatness-based controller is proposed to track the time-varying current references. Experiments are carried out on a 1.2 kW PMSM test-bench to verify the effectiveness of the proposed scheme.
The virtual synchronous generator (VSG) is a promising technology for future utility grids, since it can mimic the output characteristics of a synchronous generator, which provides the necessary inertia to a utility grid. However, the large-scale application of VSGs is limited due to the harmonic interaction between VSGs and the utility grid. Therefore, in order to investigate the stability issue as well as improve the practical application for large-scale power stations, the harmonic interaction mechanism between the VSG cluster and the utility grid is addressed. Firstly, the output impedance model of a single VSG is established, and it is found that the resonance frequency is related to parameters including the output filter, controller, and grid impedance. On this basis, the capacitor current control for a grid-connected inverter based on a VSG is proposed to enhance the resonance suppression. Furthermore, the output impedance of the VSG cluster is established, which reveals the harmonic interaction characteristics between the VSG cluster and the utility grid. In addition, in order to suppress the resonance and improve the stability, an inner-loop control strategy of VSG is introduced. Finally, the simulation and experimental results verified the correctness of the established modeling and analysis of the harmonic interaction between the clustered VSGs and the utility grid. The results show that the proposed impedance model is correct and can predict the resonant point accuracy (which is around 2.3 kHz in the simulation and experimental cases). The total harmonic distortion (THD) can be reduced to 3.2% which meets the requirements of IEEE standard 519.