Haipeng Liu

Dr. Haipeng Liu

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
Haipeng LiuHaipeng Liu
Haipeng Liu
John AllenJohn Allen
John Allen
DZDingchang Zheng
Dingchang Zheng
FCFei Chen
Fei Chen
Respiratory rate (RR) is an important physiological parameter whose abnormality has been regarded as an important indicator of serious illness. In order to make RR monitoring simple to perform, reliable and accurate, many different methods have been proposed for such automatic monitoring. According to the theory of respiratory rate extraction, methods are categorized into three modalities: extracting RR from other physiological signals, RR measurement based on respiratory movements, and RR measurement based on airflow. The merits and limitations of each method are highlighted and discussed. In addition, current works are summarized to suggest key directions for the development of future RR monitoring methodologies.

5 March 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
VHVera Hartmann
Vera Hartmann
Haipeng LiuHaipeng Liu
Haipeng Liu
FCFei Chen
Fei Chen
QQQian Qiu
Qian Qiu
SHStephen Hughes
Stephen Hughes
DZDingchang Zheng
Dingchang Zheng
Introduction: Photoplethysmography (PPG) has been widely used to assess cardiovascular function. However, few studies have comprehensively investigated the effect of measurement site on PPG waveform characteristics. This study aimed to provide a quantitative comparison on this. Methods: Thirty six healthy subjects participated in this study. For each subject, PPG signals were sequentially recorded for 1 min from six different body sites (finger, wrist under (anatomically volar), wrist upper (dorsal), arm, earlobe, and forehead) under both normal and deep breathing patterns. For each body site under a certain breathing pattern, the mean amplitude was firstly derived from recorded PPG waveform which was then normalized to derive several waveform characteristics including the pulse peak time (Tp), dicrotic notch time (Tn), and the reflection index (RI). The effects of breathing pattern and measurement site on the waveform characteristics were finally investigated by the analysis of variance (ANOVA) with post hoc multiple comparisons. Results: Under both breathing patterns, the PPG measurements from the finger achieved the highest percentage of analyzable waveforms for extracting waveform characteristics. There were significant effects of breathing pattern on Tn and RI (larger Tn and smaller RI with deep breathing on average, both p < 0.03). The effects of measurement site on mean amplitude, Tp, Tn, and RI were significant (all p < 0.001). The key results were that, under both breathing patterns, the mean amplitude from finger PPG was significantly larger and its Tp and RI were significantly smaller than those from the other five sites (all p < 0.001, except p = 0.04 for the Tp of “wrist under”), and Tn was only significantly larger than that from the earlobe (both p < 0.05). Conclusion: This study has quantitatively confirmed the effect of PPG measurement site on PPG waveform characteristics (including mean amplitude, Tp, Tn, and RI), providing scientific evidence for a better understanding of the PPG waveform variations between different body sites.

3 April 2019 in Annals of Neurology
Verified
Journal Article
Closed access
XLXinyi Leng
Xinyi Leng
LLLinfang Lan
Linfang Lan
HIHing Lung Ip
Hing Lung Ip
JAJill Abrigo
Jill Abrigo
FSFabien Scalzo
Fabien Scalzo
TLThomas W Leung
Thomas W Leung

6 September 2021 in Frontiers in Physiology
Verified
Journal Article
Open access
Haipeng LiuHaipeng Liu
Haipeng Liu
LLLinfang Lan
Linfang Lan
JAJill Abrigo
Jill Abrigo
HIHing Lung Ip
Hing Lung Ip
YSYannie Soo
Yannie Soo
XLXinyi Leng
Xinyi Leng
Background: Newtonian fluid model has been commonly applied in simulating cerebral blood flow in intracranial atherosclerotic stenosis (ICAS) cases using computational fluid dynamics (CFD) modeling, while blood is a shear-thinning non-Newtonian fluid. We aimed to investigate the differences of cerebral hemodynamic metrics quantified in CFD models built with Newtonian and non-Newtonian fluid assumptions, in patients with ICAS.Methods: We built a virtual artery model with an eccentric 75% stenosis and performed static CFD simulation. We also constructed CFD models in three patients with ICAS of different severities in the luminal stenosis. We performed static simulations on these models with Newtonian and two non-Newtonian (Casson and Carreau-Yasuda) fluid models. We also performed transient simulations on another patient-specific model. We measured translesional pressure ratio (PR) and wall shear stress (WSS) values in all CFD models, to reflect the changes in pressure and WSS across a stenotic lesion. In all the simulations, we compared the PR and WSS values in CFD models derived with Newtonian, Casson, and Carreau-Yasuda fluid assumptions.Results: In all the static and transient simulations, the Newtonian/non-Newtonian difference on PR value was negligible. As to WSS, in static models (virtual and patient-specific), the rheological difference was not obvious in areas with high WSS, but observable in low WSS areas. In the transient model, the rheological difference of WSS areas with low WSS was enhanced, especially during diastolic period.Conclusion: Newtonian fluid model could be applicable for PR calculation, but caution needs to be taken when using the Newtonian assumption in simulating WSS especially in severe ICAS cases.

23 October 2018 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Closed access
LLLinfang Lan
Linfang Lan
XLXinyi Leng
Xinyi Leng
VIVincent Ip
Vincent Ip
YSYannie Soo
Yannie Soo
JAJill Abrigo
Jill Abrigo
TLThomas W Leung
Thomas W Leung
We aimed to investigate the roles of antegrade residual flow and leptomeningeal collateral flow in sustaining cerebral perfusion distal to an intracranial atherosclerotic stenosis (ICAS). Patients with apparently normal cerebral perfusion distal to a symptomatic middle cerebral artery (MCA)-M1 stenosis were enrolled. Computational fluid dynamics models were built based on CT angiography to obtain a translesional pressure ratio (PR) to gauge the residual antegrade flow. Leptomeningeal collaterals (LMCs) were scaled on CT angiography. Cerebral perfusion metrics were obtained in CT perfusion maps. Among 83 patients, linear regression analyses revealed that both translesional PR and LMC scale were independently associated with relative ipsilesional mean transit time (rMTT). Subgroup analyses showed that ipsilesional rMTT was significantly associated with translesional PR (p < 0.001) rather than LMC scale in those with a moderate (50–69%) MCA stenosis, which, however, was only significantly associated with LMC scale (p = 0.051) in those with a severe (70–99%) stenosis. Antegrade residual flow and leptomeningeal collateral flow have complementary effects in sustaining cerebral perfusion distal to an ICAS, while cerebral perfusion may rely more on the collateral circulation in those with a severe stenosis.

1 May 2021 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
John AllenJohn Allen
John Allen
Haipeng LiuHaipeng Liu
Haipeng Liu
SISadaf Iqbal
Sadaf Iqbal
DZDingchang Zheng
Dingchang Zheng
GSGerard Stansby
Gerard Stansby
Objective. A proof-of-concept study to assess the potential of a deep learning (DL) based photoplethysmography PPG (‘DLPPG’) classification method to detect peripheral arterial disease (PAD) using toe PPG signals. Approach. PPG spectrogram images derived from our previously published multi-site PPG datasets (214 participants; 31.3% legs with PAD by ankle brachial pressure index (ABPI)) were input into a pretrained 8-layer (five convolutional layers + three fully connected layers) AlexNet as tailored to the 2-class problem with transfer learning to fine tune the convolutional neural network (CNN). k -fold random cross validation (CV) was performed (for k = 5 and k = 10), with each evaluated over k training/validation runs. Overall test sensitivity, specificity, accuracy, and Cohen’s Kappa statistic with 95% confidence interval ranges were calculated and compared, as well as sensitivities in detecting mild-moderate (0.5 ≤ ABPI < 0.9) and major (ABPI < 0.5) levels of PAD. Main results. CV with either k = 5 or 10 folds gave similar diagnostic performances. The overall test sensitivity was 86.6%, specificity 90.2% and accuracy 88.9% (Kappa: 0.76 [0.70–0.82]) (at k = 5). The sensitivity to mild-moderate disease was 83.0% (75.5%–88.9%) and to major disease was 100.0% (90.5%–100.0%). Significance. Substantial agreements have been demonstrated between the DL-based PPG classification technique and the ABPI PAD diagnostic reference. This novel automatic approach, requiring minimal pre-processing of the pulse waveforms before PPG trace classification, could offer significant benefits for the diagnosis of PAD in a variety of clinical settings where low-cost, portable and easy-to-use diagnostics are desirable.