John Allen

Prof. John Allen

Chair in Biosensors and Bioinstrumentation
+1

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2007 in Physiological Measurement
Verified
Journal Article
Closed access
John AllenJohn Allen
John Allen
Photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the microvascular bed of tissue. It is often used non-invasively to make measurements at the skin surface. The PPG waveform comprises a pulsatile ('AC') physiological waveform attributed to cardiac synchronous changes in the blood volume with each heart beat, and is superimposed on a slowly varying ('DC') baseline with various lower frequency components attributed to respiration, sympathetic nervous system activity and thermoregulation. Although the origins of the components of the PPG signal are not fully understood, it is generally accepted that they can provide valuable information about the cardiovascular system. There has been a resurgence of interest in the technique in recent years, driven by the demand for low cost, simple and portable technology for the primary care and community based clinical settings, the wide availability of low cost and small semiconductor components, and the advancement of computer-based pulse wave analysis techniques. The PPG technology has been used in a wide range of commercially available medical devices for measuring oxygen saturation, blood pressure and cardiac output, assessing autonomic function and also detecting peripheral vascular disease. The introductory sections of the topical review describe the basic principle of operation and interaction of light with tissue, early and recent history of PPG, instrumentation, measurement protocol, and pulse wave analysis. The review then focuses on the applications of PPG in clinical physiological measurements, including clinical physiological monitoring, vascular assessment and autonomic function.

1 July 2019 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
Haipeng LiuHaipeng Liu
Haipeng Liu
John AllenJohn Allen
John Allen
DZDingchang Zheng
Dingchang Zheng
FCFei Chen
Fei Chen
Respiratory rate (RR) is an important physiological parameter whose abnormality has been regarded as an important indicator of serious illness. In order to make RR monitoring simple to perform, reliable and accurate, many different methods have been proposed for such automatic monitoring. According to the theory of respiratory rate extraction, methods are categorized into three modalities: extracting RR from other physiological signals, RR measurement based on respiratory movements, and RR measurement based on airflow. The merits and limitations of each method are highlighted and discussed. In addition, current works are summarized to suggest key directions for the development of future RR monitoring methodologies.

1 November 2023 in Physiological Measurement
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
John AllenJohn Allen
John Allen
Raquel BailónRaquel Bailón
Raquel Bailón
SBStephanie Baker
Stephanie Baker
JBJoachim A Behar
Joachim A Behar
TZTingting Zhu
Tingting Zhu
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.

18 December 2006 in Journal of Neurology, Neurosurgery & Psychiatry
Verified
Journal Article
Closed access
LAL M Allan
L M Allan
CBClive Mr. Ballard
Clive Mr. Ballard
John AllenJohn Allen
John Allen
AMA Murray
A Murray
ADA W Davidson
A W Davidson
RKR A Kenny
R A Kenny
There are no studies of autonomic function comparing Alzheimer's disease (AD), vascular dementia (VAD), dementia with Lewy bodies (DLB) and Parkinson's disease dementia (PDD). To assess cardiovascular autonomic function in 39 patients with AD, 30 with VAD, 30 with DLB, 40 with PDD and 38 elderly controls by Ewing's battery of autonomic function tests and power spectral analysis of heart rate variability. To determine the prevalence of orthostatic hypotension and autonomic neuropathies by Ewing's classification. There were significant differences in severity of cardiovascular autonomic dysfunction between the four types of dementia. PDD and DLB had considerable dysfunction. VAD showed limited evidence of autonomic dysfunction and in AD, apart from orthostatic hypotension, autonomic functions were relatively unimpaired. PDD showed consistent impairment of both parasympathetic and sympathetic function tests in comparison with controls (all p<0.001) and AD (all p<0.03). DLB showed impairment of parasympathetic function (all p<0.05) and one of the sympathetic tests in comparison with controls (orthostasis; p = 0.02). PDD had significantly more impairment than DLB in some autonomic parameters (Valsalva ratio: p = 0.024; response to isometric exercise: p = 0.002). Patients with VAD showed impairment in two parasympathetic tests (orthostasis: p = 0.02; Valsalva ratio: p = 0.08) and one sympathetic test (orthostasis: p = 0.04). These results were in contrast with AD patients who only showed impairment in one sympathetic response (orthostasis: p = 0.004). The prevalence of orthostatic hypotension and autonomic neuropathies was higher in all dementias than in controls (all p<0.05). Autonomic dysfunction occurs in all common dementias but is especially prominent in PDD with important treatment implications.

13 March 2003 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
John AllenJohn Allen
John Allen
AMAlan Murray
Alan Murray
It is accepted that older subjects have increasing arterial stiffness resulting in changes in the propagation of the pulse to the periphery, and thereby influencing the peripheral pulse timing and shape characteristics. However, this age association with pulse shape is less clear in younger subjects and for different peripheral measurement sites. The aim of this study was to determine the association between age and changes in pulse shape characteristics at the ears, fingers and toes. Photoplethysmography pulse waveforms were recorded non-invasively from the right and left sides at the ears, index fingers and great toes of 116 normal healthy human subjects. Their median age was 41 years (range 13-72) allowing four distinct age groups to be considered (subjects younger than 30 years, 30-39 years, 40-49 years and 50 years of age or older). Normalized ear, finger and toe pulse shapes were calculated, for the whole subject group, and for the subjects within each age group. The differences in shape, relative to the oldest group, were also calculated for two distinct regions of interest: the systolic rising edge and the dicrotic notch of the pulse. Subtle, gradual and significant changes in the pulse shape were found at all sites with overall elongation of the systolic rising edge (p < 0.05) and damping of the dicrotic notch (p < 0.05) with age. The overall age-related changes in multi-site PPG pulse shape characteristics at the ear, finger and toe sites have been demonstrated and quantified. Age-matched normal ranges must be considered when evaluating pulses from patients with possible vascular disease.

9 June 2014 in Physiological Measurement
Verified
Journal Article
Closed access
John AllenJohn Allen
John Allen
KHKevin Howell
Kevin Howell
The microvasculature presents a particular challenge in physiological measurement because the vessel structure is spatially inhomogeneous and perfusion can exhibit high variability over time. This review describes, with a clinical focus, the wide variety of methods now available for imaging of the microvasculature and their key applications. Laser Doppler perfusion imaging and laser speckle contrast imaging are established, commercially-available techniques for determining microvascular perfusion, with proven clinical utility for applications such as burn-depth assessment. Nailfold capillaroscopy is also commercially available, with significant published literature that supports its use for detecting microangiopathy secondary to specific connective tissue diseases in patients with Raynaud's phenomenon. Infrared thermography measures skin temperature and not perfusion directly, and it has only gained acceptance for some surgical and peripheral microvascular applications. Other emerging technologies including imaging photoplethysmography, optical coherence tomography, photoacoustic tomography, hyperspectral imaging, and tissue viability imaging are also described to show their potential as techniques that could become established tools for clinical microvascular assessment. Growing interest in the microcirculation has helped drive the rapid development in perfusion imaging of the microvessels, bringing exciting opportunities in microvascular research.