Mauro Zucca

Dr. Mauro Zucca

Istituto Nazionale di Ricerca Metrologica – INRiM, Torino, Italy
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Open access
AAAlessandro Arduino
Alessandro Arduino
OBOriano Bottauscio
Oriano Bottauscio
MCMario Chiampi
Mario Chiampi
Luca GiacconeLuca Giaccone
Luca Giaccone
ILIlaria Liorni
Ilaria Liorni
MZMauro Zucca
Mauro Zucca
In this article, we discuss numerical aspects related to the accuracy and the computational efficiency of numerical dosimetric simulations, performed in the context of human exposure to static inductive charging systems of electric vehicles. Two alternative numerical methods based on electric vector potential and electric scalar potential formulations, respectively, are here considered for the electric field computation in highly detailed anatomical human models. The results obtained by the numerical implementation of both approaches are discussed in terms of compliance assessment with ICNIRP guidelines limits for human exposure to electromagnetic fields. In particular, different strategies for smoothing localized unphysical outliers are compared, including novel techniques based on statistical considerations. The outlier removal is particularly relevant when comparison with basic restrictions is required to define the safety of electromagnetic fields exposure. The analysis demonstrates that it is not possible to derive general conclusions about the most robust method for dosimetric solutions. Nevertheless, the combined use of both formulations, together with the use of an algorithm for outliers removal based on a statistical approach, allows to determine final results to be compared with reference limits with a significant level of reliability.

3 June 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
ILIlaria Liorni
Ilaria Liorni
OBOriano Bottauscio
Oriano Bottauscio
RGRoberta Guilizzoni
Roberta Guilizzoni
PAPeter Ankarson
Peter Ankarson
JBJorge Bruna
Jorge Bruna
MZMauro Zucca
Mauro Zucca
High-power inductive power transfer (IPT) systems for charging light and heavy electric vehicles pose safety concerns if they are installed in uncontrolled environments. Within the framework of the European Project EMPIR-16ENG08 MICEV, a wide experimental and numerical study was conducted to assess the exposure of the general public to IPT stray magnetic fields for two different exposure scenarios: (1) for an IPT model system derived from the SAE J2954 standard operating at 85 kHz for a light electric vehicle coupled with the model of a realistic car-body model; and (2) for an IPT model system with a maximum rated power of 50 kW at 27.8 kHz for a real minibus that was reproduced with some simplifications in two different 3D finite element method (FEM) simulation tools (Opera 3D and CST software). An ad hoc measurement survey was carried out at the minibus charging station to validate the simulations of the real bus station for both aligned and misaligned IPT coils. Based on this preliminary study, a safety factor was chosen to ensure a conservative dosimetric analysis with respect to the model approximations. As highlighted in this study, the vehicle-body serves as an efficient screen to reduce the magnetic field by at least three orders of magnitude close to the coils. By applying FEM, computed spatial distribution to the Sim4Life software, the exposure of three Virtual Population human anatomical phantoms (one adult, one child, and a newborn) was assessed. The three phantoms were placed in different postures and locations for both exposure scenarios. The basic restriction limits, established by the current guidelines, were never exceeded within the vehicles; however, the basic restrictions were exceeded when an adult crouched outside the minibus, i.e., near the coils, or when a newborn was placed in the same location. Borderline values were observed in the light car. In the case of the bus, limits coming from the Institute of Electrical and Electronics Engineers (IEEE) guidelines are never exceeded, while basic restrictions coming from the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines are exceeded up to 12% for an adult and up to 38% for a newborn. This paper presents novel dosimetric data generated in an IPT system for heavy vehicles and confirms some of the literature data on light vehicles.

23 December 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
MZMauro Zucca
Mauro Zucca
PSPaolo Squillari
Paolo Squillari
PUPogliano Umberto
Pogliano Umberto
This article describes a new traceable measurement system, designed for the characterization of inductive charging stations for electric vehicles. This article particularly focuses on static charging (stationary vehicle), while dynamic charging (charging while driving) requires a significantly different system. The measurement system is able to measure on-site performance and efficiency of the charging station and converters. The relative uncertainty is ≤10 −3 . The measurement system aims at accurately measure the power at the batteries and the power transferred from the ground to the onboard resonant circuit and makes possible a benchmarking between station measuring systems. Finally, this measurement system allows the characterization of the magnetic emissions by correlating them with the electric current in the coils. This system improves the ease and ability to characterize wireless charging stations both in field and laboratory environments. This article describes in detail the hardware, the software, the GPS synchronization, and, in summary, the system architecture.

31 October 2023 in IEEE Access
Verified
Journal Article
Open access
MZMauro Zucca
Mauro Zucca
MHMelika Hassanzadeh
Melika Hassanzadeh
Ornella ContiOrnella Conti
Ornella Conti
PUPogliano Umberto
Pogliano Umberto
Supercapacitors are becoming increasingly important storage system components. To effectively control their terminal voltage, even in real time, numerous circuit models capable of faithfully simulating their behavior in energy systems and various applications are being explored. The three-branch supercapacitor model appears to be a good compromise between simplicity and accuracy. Typically, this model lacks accuracy in dynamic cycling and long stand-by periods. In this study, a new model identification method based on the state equations of the circuit is described and tested on a 400 F supercapacitor, and the obtained results are validated by measurements. Such an approach, suitably optimized, provides good agreement with the measurements, with discrepancies below 50 mV even in repeated cycles. In the static identification, after 90 minutes of self-discharge, the discrepancy was approximately 5 mV. The study also discusses the sensitivity of the model output to the circuit parameters, which is useful for choosing the appropriate timespan for parameter optimization and introduces variable leakage resistance and a method for its determination. Through this parameter, good agreement with the measurements is observed during the long self-discharging phases. A discrepancy of less than 50 mV between the measured and computed results is observed after one week. The union of the circuit state equations based model and the nonlinear leakage resistance determination allows the three-branch circuit model to achieve a high accuracy both in real-time simulation and in the presence of long stand-by phases.

30 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
MZMauro Zucca
Mauro Zucca
MMMohammad Modarres
Mohammad Modarres
PUPogliano Umberto
Pogliano Umberto
DSDanilo Serazio
Danilo Serazio
A new reference resistive-capacitive voltage divider is presented in this paper, operating in dc and ac from 10 to 200 kHz. The ratio error is lower than 0.1% and the phase error is lower than 400 μrad (1.375') at 100 kHz. The divider is stable and repeatable. The scale factor (SF) and the phase error repeatability, tested in 24-h continuous measurements repeated during 15 weeks, show an SF variation lower than 80 ppm and a phase error variation lower than 20 μrad. This allows one to define a calibration matrix of the device bringing its relative measurement uncertainty lower than 0.5 . 10 -3 . The divider calibration has been obtained with a step-up method, which could improve traceability in many laboratories and is described in this paper. The divider can be embedded in a calibration chain to test the accuracy of voltage transducers in the measurement of the ac voltage ripple, in the presence of a significant dc component, as it occurs in many power electronic systems. The voltage calibration chain is based on the use of the reference divider and a voltage injector, the secondary of which is placed in series with a stable dc source. By means of this calibration system, one of the best commercial voltage transducers on the market has been analyzed. This paper also highlights how the proposed voltage calibration chain could be used in perspective in a phantom power system for the development of a dc plus ac power standard.

1 June 2000 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
OBOriano Bottauscio
Oriano Bottauscio
MCM Chiampi
M Chiampi
DCD Chiarabaglio
D Chiarabaglio
MZMauro Zucca
Mauro Zucca