This paper presents algorithms for detection of gait initiation and termination using wearable inertial measurement units and pressure-sensitive insoles. Body joint angles, joint angular velocities, ground reaction force and center of plantar pressure of each foot are obtained from these sensors and input into supervised machine learning algorithms. The proposed initiation detection method recognizes two events: gait onset (an anticipatory movement preceding foot lifting) and toe-off. The termination detection algorithm segments gait into steps, measures the signals over a buffer at the beginning of each step, and determines whether this measurement belongs to the final step. The approach is validated with 10 subjects at two gait speeds, using within-subject and subject-independent cross-validation. Results show that gait initiation can be detected timely and accurately, with few errors in the case of within-subject cross-validation and overall good performance in subject-independent cross-validation. Gait termination can be predicted in over 80% of trials well before the subject comes to a complete stop. Results also show that the two sensor types are equivalent in predicting gait initiation while inertial measurement units are generally superior in predicting gait termination. Potential use of the algorithms is foreseen primarily with assistive devices such as prostheses and exoskeletons.
5 March 2012 in IEEE Transactions on Instrumentation and Measurement
Inexpensive inertial/magnetic measurement units can be found in numerous applications and are typically used to determine orientation. Due to the presence of nonidealities in measurement systems, the calibration of the sensor is thus needed to determine sensor parameters such as bias, misalignment, and gain/sensitivity. In this paper, an online automatic calibration method for a three-axial accelerometer is presented. Parameters are estimated using an unscented Kalman filter. The sensor is placed in a number of different orientations using a robotic arm. These orientations are calculated online from the parameter covariance matrix and represent estimated optimal sensor orientations for parameter estimation. Numerous simulations are run to evaluate the proposed calibration method, and a comparison is made with an offline least mean squares calibration method. The simulation results show that calibration with the proposed method results in higher accuracy of parameter estimation when using less than 100 iterations. The proposed calibration method is also applied to a real accelerometer using a low number of iterations. The results show only slight (less than 0.4%) changes in parameter values between different calibration runs. The proposed calibration method provides an accurate parameter estimation using a small number of iterations without the need for manually predefining orientations of the sensor, and the method can be used in combination with other offline calibration methods to achieve even higher accuracy.
We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant’Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant’Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted.
12 April 2010 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
This paper presents the analysis of four psychophysiological responses in post-stroke upper extremity rehabilitation. The goal was to determine which psychophysiological responses would provide the most reliable information about subjects' psychological states during rehabilitation. Heart rate, skin conductance, respiration, and skin temperature were recorded in a stroke group and a control group during two difficulty levels of a pick-and-place task performed in a virtual environment using a haptic robot and during a cognitive task. Psychophysiological measurements were correlated with results of a self-report questionnaire. All four responses showed significant changes in response to the different tasks. Skin conductance differentiated between the two difficulty levels and was correlated with self-reported arousal in both stroke and control groups. Skin temperature differentiated between the two difficulty levels for the control group, but provided poor results for the stroke group. Heart rate and respiration increased during tasks, but their connection to psychological state was unclear. Results suggest that, of the four measured responses, skin conductance offers the most potential as a psychological state indicator, with other measures providing supplementary information. Psychophysiological measurements could thus be used in closed-loop biocooperative systems that would detect the user's psychological state and change the course of therapy accordingly.
Previous studies have presented algorithms for detection of turns during gait using wearable sensors, but those algorithms were not built for real-time use. This paper therefore investigates the optimal approach for real-time detection of planned turns during gait using wearable inertial measurement units. Several different sensor positions (head, back and legs) and three different detection criteria (orientation, angular velocity and both) are compared with regard to their ability to correctly detect turn onset. Furthermore, the different sensor positions are compared with regard to their ability to predict the turn direction and amplitude. The evaluation was performed on ten healthy subjects who performed left/right turns at three amplitudes (22, 45 and 90 degrees). Results showed that turn onset can be most accurately detected with sensors on the back and using a combination of orientation and angular velocity. The same setup also gives the best prediction of turn direction and amplitude. Preliminary measurements with a single amputee were also performed and highlighted important differences such as slower turning that need to be taken into account.
13 February 2014 in IEEE Transactions on Instrumentation and Measurement
The inertial/magnetic measurement units are an affordable instrument for the determination of orientation. The sensors embedded in the system are affected by nonidealities that can be greatly compensated by proper calibration, by determining sensor parameters, such as bias, misalignment, and sensitivity/gain. This paper presents an online calibration method for a three-axial magnetometer using a 3-D Helmholtz coil. The magnetometer is exposed to different directions of the magnetic field created by the 3-D coil. The parameters are estimated by using an unscented Kalman filter. The directions are calculated online by using a sensor parameter covariance matrix. The method evaluation is achieved by first running numerous simulations, followed by experiments using a real magnetometer, finally resulting in better accuracy of parameter estimation with a low number of measurement iterations compared with the method where magnetic field directions are determined manually.