Banafsaj Rasool

Mrs. Banafsaj Rasool


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2021 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
BRBanafsaj Rasool
Banafsaj Rasool
JNJeffrey Alan Neasham
Jeffrey Alan Neasham
Patrick A G DegenaarPatrick A G Degenaar
Patrick A G Degenaar
Modern Active Medical Implantable Devices require communications to transmit information to the outside world or other implantable sub-systems. This can include physiological data, diagnostics, and parameters to optimise the therapeutic protocol. The available options are to use optical, radiofrequency, or ultrasonic communications. However, in all cases, transmission becomes more difficult with deeper transmission through tissue. Challenges include absorption and scattering by tissue, and the need to ensure there are no undesirable heating effects. As such, this paper aims to review research progress in using ultrasound as an alternative for deep tissue communications. We provide an empirical review of the technology and communication protocols that different groups have used, as well as comparing the implications in terms of penetration depth, implant size, and data rate. We conclude that this technique has promise for deeper implants and for intrabody communications between implantable devices (intrabody networks).

19 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
BRBanafsaj Rasool
Banafsaj Rasool
JLjunwen Luo
junwen Luo
DFDimitrios Firfilionis
Dimitrios Firfilionis
ASAhmed Soltan
Ahmed Soltan
JNJeff Neasham
Jeff Neasham
Patrick A G DegenaarPatrick A G Degenaar
Patrick A G Degenaar
The coming years may see the advent of distributed implantable devices to support bioelectronic medicinal treatments. Communication between implantable components and between deep implants and the outside world can be challenging. Percutaneous wired connectivity is undesirable and both radiofrequency and optical methods are limited by tissue absorption and power safety limits. As such, there is a significant potential niche for ultrasound communications in this domain. In this paper, we present the design and testing of a reliable and efficient ultrasonic communication telemetry scheme using piezoelectric transducers that operate at 320 kHz frequency. A key challenge results from the multi-propagation path effect. Therefore, we present a method, using short pulse sequences with relaxation intervals. To counter an increasing bit, and thus packet, error rate with distance, we have incorporated an error correction encoding scheme. We then demonstrate how the communication scheme can scale to a network of implantable devices. We demonstrate that we can achieve an effective, error-free, data rate of 0.6 kbps, which is sufficient for low data rate bioelectronic medicine applications. Transmission can be achieved at an energy cost of 642 nJ per bit data packet using on/off power cycling in the electronics.