junwen Luo

Dr. junwen Luo


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
JLjunwen Luo
junwen Luo
DFDimitris Firflionis
Dimitris Firflionis
MTMark Turnbull
Mark Turnbull
WXWei Xu
Wei Xu
DWDarren Walsh
Darren Walsh
PDPatrick Degenaar
Patrick Degenaar
Brain-machine Interfaces (BMI) hold great potential for treating neurological disorders such as epilepsy. Technological progress is allowing for a shift from open-loop, pacemaker-class, intervention towards fully closed-loop neural control systems. Low power programmable processing systems are therefore required which can operate within the thermal window of 2° C for medical implants and maintain long battery life. In this work, we have developed a low power neural engine with an optimized set of algorithms which can operate under a power cycling domain. We have integrated our system with a custom-designed brain implant chip and demonstrated the operational applicability to the closed-loop modulating neural activities in in-vitro and in-vivo brain tissues: the local field potentials can be modulated at required central frequency ranges. Also, both a freely-moving non-human primate (24-hour) and a rodent (1-hour) in-vivo experiments were performed to show system reliable recording performance. The overall system consumes only 2.93 mA during operation with a biological recording frequency 50 Hz sampling rate (the lifespan is approximately 56 hours). A library of algorithms has been implemented in terms of detection, suppression and optical intervention to allow for exploratory applications in different neurological disorders. Thermal experiments demonstrated that operation creates minimal heating as well as battery performance exceeding 24 hours on a freely moving rodent. Therefore, this technology shows great capabilities for both neuroscience in-vitro/in-vivo applications and medical implantable processing units.

19 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
BRBanafsaj Rasool
Banafsaj Rasool
JLjunwen Luo
junwen Luo
DFDimitrios Firfilionis
Dimitrios Firfilionis
ASAhmed Soltan
Ahmed Soltan
JNJeff Neasham
Jeff Neasham
Patrick A G DegenaarPatrick A G Degenaar
Patrick A G Degenaar
The coming years may see the advent of distributed implantable devices to support bioelectronic medicinal treatments. Communication between implantable components and between deep implants and the outside world can be challenging. Percutaneous wired connectivity is undesirable and both radiofrequency and optical methods are limited by tissue absorption and power safety limits. As such, there is a significant potential niche for ultrasound communications in this domain. In this paper, we present the design and testing of a reliable and efficient ultrasonic communication telemetry scheme using piezoelectric transducers that operate at 320 kHz frequency. A key challenge results from the multi-propagation path effect. Therefore, we present a method, using short pulse sequences with relaxation intervals. To counter an increasing bit, and thus packet, error rate with distance, we have incorporated an error correction encoding scheme. We then demonstrate how the communication scheme can scale to a network of implantable devices. We demonstrate that we can achieve an effective, error-free, data rate of 0.6 kbps, which is sufficient for low data rate bioelectronic medicine applications. Transmission can be achieved at an energy cost of 642 nJ per bit data packet using on/off power cycling in the electronics.