This paper reports a novel micro-fluxgate sensor based on a double-layer magnetic core of a Fe–Co–B-based amorphous ribbon. The melt-spinning technique was carried out to obtain a Fe–Co–B-based amorphous ribbon composite of Fe58.1Co24.9B16Si1, and the obtained amorphous ribbon was then annealed at 595 K for 1 h to benefit soft magnetic properties. The prepared ribbon showed excellent soft magnetic behavior with a high saturated magnetic intensity (Bs) of 1.74 T and a coercivity (Hc) of less than 0.2 Oe. Afterward, a micro-fluxgate sensor based on the prepared amorphous ribbon was fabricated via microelectromechanical systems (MEMS) technology combined with chemical wet etching. The resulting sensor exhibited a sensitivity of 1985 V/T, a wide linearity range of ±1.05 mT, and a perming error below 0.4 μT under optimal operating conditions with an excitation current amplitude of 70 mA at 500 kHz frequency. The minimum magnetic field noise was about 36 pT/Hz1/2 at 1 Hz under the same excitation conditions; a superior resolution of 5 nT was also achieved in the fabricated sensor. To the best of our knowledge, a compact micro-fluxgate sensor with such a high-resolution capability has not been reported elsewhere. The microsensor presented here with such improved characteristics may considerably enhance the development of micro-fluxgate sensors.
A sensitive and innovative assay system based on a micro-MEMS-fluxgate sensor and immunomagnetic beads-labels was developed for the rapid analysis of C-reactive proteins (CRP). The fluxgate sensor presented in this study was fabricated through standard micro-electro-mechanical system technology. A multi-loop magnetic core made of Fe-based amorphous ribbon was employed as the sensing element, and 3-D solenoid copper coils were used to control the sensing core. Antibody-conjugated immunomagnetic microbeads were strategically utilized as signal tags to label the CRP via the specific conjugation of CRP to polyclonal CRP antibodies. Separate Au film substrates were applied as immunoplatforms to immobilize CRP-beads labels through classical sandwich assays. Detection and quantification of the CRP at different concentrations were implemented by detecting the stray field of CRP labeled magnetic beads using the newly-developed micro-fluxgate sensor. The resulting system exhibited the required sensitivity, stability, reproducibility, and selectivity. A detection limit as low as 0.002 μg/mL CRP with a linearity range from 0.002 μg/mL to 10 μg/mL was achieved, and this suggested that the proposed biosystem possesses high sensitivity. In addition to the extremely low detection limit, the proposed method can be easily manipulated and possesses a quick response time. The response time of our sensor was less than 5 s, and the entire detection period for CRP analysis can be completed in less than 30 min using the current method. Given the detection performance and other advantages such as miniaturization, excellent stability and specificity, the proposed biosensor can be considered as a potential candidate for the rapid analysis of CRP, especially for point-of-care platforms.
25 February 2019 in Microfluidics and Nanofluidics
This article presents a general-purpose model that enables efficient and accurate calculation of third-order nonlinear signals in surface acoustic wave (SAW) devices. This model is based on piezoelectric constitutive equations combined with perturbation theory, which can be analyzed by full finite element method (FEM). For validation, third-order harmonic (H3) responses and intermodulation distortions (IMD3) in SAW resonators are simulated, and their calculation results fit well to experimental data in the literature. Then, the generation mechanisms of the third-order nonlinearity in SAW resonators are discussed. The dominant generation mechanisms for different nonlinear signals and the relation between electrode materials and H3 peak magnitude are revealed, which provides an important guideline for further nonlinear suppression.
In this paper, the performance of orthogonal fluxgate sensors with meander-shaped cores is studied in fundamental mode. The meander-shaped cores are made by micro-patterning technology based on a Co-based amorphous ribbon. The main advantage of this structure is that the linear operating range of the sensor can be adjusted simply by changing the number of strips, without affecting the excitation mechanism. Experiments show that a linear range of 560 μT is obtained by a meander-shaped core sensor with 12 strips. The changes in the number of strips can also increase sensitivity and reduce noise of the sensor. We can achieve a sensitivity of 600 V/T and a noise level of 0.64 nT/√Hz at 1 Hz for a meander-shaped core sensor with eight strips. Compared with the performance of the sensors built using a single strip core having the same equivalent cross-sectional area, the use of meander-shaped core can provide a higher sensitivity and linearity, and a lower noise level. We also compare the performance of an eight-strip meander-shaped core orthogonal fluxgate operated in the fundamental and second-harmonic modes. Similar sensitivity for the two modes can be obtained by adjusting the excitation current. In this case, we find that the noise of sensor operating in fundamental mode is about five times lower than that of the sensor operating in second-harmonic mode. This can be interpreted as the suppression of Barkhausen noise by unipolar bias in the fundamental mode.