Evgeniya Krivkina

Ms. Evgeniya Krivkina

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ОГОльга Викторовна Груздева
Ольга Викторовна Груздева
YDYulia Dyleva
Yulia Dyleva
EBEkaterina Belik
Ekaterina Belik
MSMaxim Sinitsky
Maxim Sinitsky
ASAleksandr N. Stasev
Aleksandr N. Stasev
OBOlga Barbarash
Olga Barbarash
Adipose tissue (AT) is an endocrine and paracrine organ that synthesizes biologically active adipocytokines, which affect inflammation, fibrosis, and atherogenesis. Epicardial and perivascular fat depots are of great interest to researchers, owing to their potential effects on the myocardium and blood vessels. The aim of the study was to assess the expression and secretion of adipocytokine genes in the AT of patients with coronary artery disease (CAD) and patients with aortic or mitral valve replacement. This study included 84 patients with CAD and 50 patients with aortic or mitral valve replacement. Adipocytes were isolated from subcutaneous, epicardial (EAT), and perivascular AT (PVAT), and were cultured for 24 h. EAT exhibited the lowest level of adiponectin gene expression and secretion, regardless of nosology, and high expression levels of the leptin gene and interleukin-6 (IL-6). However, EAT adipocytes in patients with CAD were characterized by more pronounced changes in comparison with the group with heart defects. High leptin and IL-6 levels resulted in increased pro-inflammatory activity, as observed in both EAT and PVAT adipocytes, especially in individuals with CAD. Therefore, our results revealed the pathogenetic significance of alterations in the adipokine and cytokine status of adipocytes of EAT and PVAT in patients with CAD.

Verified
Journal Article
Open access
PDF file
DSDaria Shishkova
Daria Shishkova
EVElena Velikanova
Elena Velikanova
LBLeo A. Bogdanov
Leo A. Bogdanov
MSMaxim Yu. Sinitsky
Maxim Yu. Sinitsky
AKAlexander Kostyunin
Alexander Kostyunin
AKAnton Kutikhin
Anton Kutikhin
An association between high serum calcium/phosphate and cardiovascular events or death is well-established. However, a mechanistic explanation of this correlation is lacking. Here, we examined the role of calciprotein particles (CPPs), nanoscale bodies forming in the human blood upon its supersaturation with calcium and phosphate, in cardiovascular disease. The serum of patients with coronary artery disease or cerebrovascular disease displayed an increased propensity to form CPPs in combination with elevated ionised calcium as well as reduced albumin levels, altogether indicative of reduced Ca2+-binding capacity. Intravenous administration of CPPs to normolipidemic and normotensive Wistar rats provoked intimal hyperplasia and adventitial/perivascular inflammation in both balloon-injured and intact aortas in the absence of other cardiovascular risk factors. Upon the addition to primary human arterial endothelial cells, CPPs induced lysosome-dependent cell death, promoted the release of pro-inflammatory cytokines, stimulated leukocyte adhesion, and triggered endothelial-to-mesenchymal transition. We concluded that CPPs, which are formed in the blood as a result of altered mineral homeostasis, cause endothelial dysfunction and vascular inflammation, thereby contributing to the development of cardiovascular disease.

Verified
Journal Article
Open access
PDF file
LALarisa Antonova
Larisa Antonova
Alexander Marcus SeifalianAlexander Marcus Seifalian
Alexander Marcus Seifalian
AKAnton Kutikhin
Anton Kutikhin
VSViktoriia Sevostianova
Viktoriia Sevostianova
VMVera Matveeva
Vera Matveeva
LBLeonid Barbarash
Leonid Barbarash
The blend of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) and poly(ε-caprolactone) (PCL) has recently been considered promising for vascular tissue engineering. However, it was shown that PHBV/PCL grafts require biofunctionalization to achieve high primary patency rate. Here we compared immobilization of arginine–glycine–aspartic acid (RGD)-containing peptides and the incorporation of vascular endothelial growth factor (VEGF) as two widely established biofunctionalization approaches. Electrospun PHBV/PCL small-diameter grafts with either RGD peptides or VEGF, as well as unmodified grafts were implanted into rat abdominal aortas for 1, 3, 6, and 12 months following histological and immunofluorescence assessment. We detected CD31+/CD34+/vWF+ cells 1 and 3 months postimplantation at the luminal surface of PHBV/PCL/RGD and PHBV/PCL/VEGF, but not in unmodified grafts, with the further observation of CD31+CD34−vWF+ phenotype. These cells were considered as endothelial and produced a collagen-positive layer resembling a basement membrane. Detection of CD31+/CD34+ cells at the early stages with subsequent loss of CD34 indicated cell adhesion from the bloodstream. Therefore, either conjugation with RGD peptides or the incorporation of VEGF promoted the formation of a functional endothelial cell layer. Furthermore, both modifications increased primary patency rate three-fold. In conclusion, both of these biofunctionalization approaches can be considered as equally efficient for the modification of tissue-engineered vascular grafts.

8 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
LALarisa Antonova
Larisa Antonova
EKEvgeniya Krivkina
Evgeniya Krivkina
VSViktoriia Sevostianova
Viktoriia Sevostianova
AMAndrey V. Mironov
Andrey V. Mironov
MRMaria Rezvova
Maria Rezvova
LBLeonid Barbarash
Leonid Barbarash
Tissue-engineered vascular graft for the reconstruction of small arteries is still an unmet clinical need, despite the fact that a number of promising prototypes have entered preclinical development. Here we test Poly(3-hydroxybutyrate-co-3-hydroxyvalerate)Poly(ε-caprolactone) 4-mm-diameter vascular grafts equipped with vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF) and stromal cell-derived factor 1α (SDF-1α) and surface coated with heparin and iloprost (PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo, n = 8) in a sheep carotid artery interposition model, using biostable vascular prostheses of expanded poly(tetrafluoroethylene) (ePTFE, n = 5) as a control. Primary patency of PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo grafts was 62.5% (5/8) at 24 h postimplantation and 50% (4/8) at 18 months postimplantation, while all (5/5) ePTFE conduits were occluded within the 24 h after the surgery. At 18 months postimplantation, PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo grafts were completely resorbed and replaced by the vascular tissue. Regenerated arteries displayed a hierarchical three-layer structure similar to the native blood vessels, being fully endothelialised, highly vascularised and populated by vascular smooth muscle cells and macrophages. The most (4/5, 80%) of the regenerated arteries were free of calcifications but suffered from the aneurysmatic dilation. Therefore, biodegradable PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo grafts showed better short- and long-term results than bio-stable ePTFE analogues, although these scaffolds must be reinforced for the efficient prevention of aneurysms.

18 January 2019 in Polymers
Verified
Journal Article
Open access
PDF file
LALarisa Antonova
Larisa Antonova
VSVladimir N. Sil’nikov
Vladimir N. Sil’nikov
VSViktoriia Sevostianova
Viktoriia Sevostianova
Arseniy E YuzhalinArseniy E Yuzhalin
Arseniy E Yuzhalin
LKLyudmila S. Koroleva
Lyudmila S. Koroleva
LBLeonid Barbarash
Leonid Barbarash
Modification with Arg-Gly-Asp (RGD) peptides is a promising approach to improve biocompatibility of small-calibre vascular grafts but it is unknown how different RGD sequence composition impacts graft performance. Here we manufactured 1.5 mm poly(3-hydroxybutyrate-co-3-hydroxyvalerate)/poly(ε-caprolactone) grafts modified by distinct linear or cyclic RGD peptides immobilized by short or long amine linker arms. Modified vascular prostheses were tested in vitro to assess their mechanical properties, hemocompatibility, thrombogenicity and endothelialisation. We also implanted these grafts into rat abdominal aortas with the following histological examination at 1 and 3 months to evaluate their primary patency, cellular composition and detect possible calcification. Our results demonstrated that all modes of RGD modification reduce ultimate tensile strength of the grafts. Modification of prostheses does not cause haemolysis upon the contact with modified grafts, yet all the RGD-treated grafts display a tendency to promote platelet aggregation in comparison with unmodified counterparts. In vivo findings identify that cyclic Arg-Gly-Asp-Phe-Lys peptide in combination with trioxa-1,13-tridecanediamine linker group substantially improve graft biocompatibility. To conclude, here we for the first time compared synthetic small-diameter vascular prostheses with different modes of RGD modification. We suggest our graft modification regimen as enhancing graft performance and thus recommend it for future use in tissue engineering.

8 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
MRMaria Rezvova
Maria Rezvova
PNPavel Nikishau
Pavel Nikishau
Sergei V KostjukSergei V Kostjuk
Sergei V Kostjuk
TGTatyana Glushkova
Tatyana Glushkova
LBLeonid Barbarash
Leonid Barbarash
Superior polymers represent a promising alternative to mechanical and biological materials commonly used for manufacturing artificial heart valves. The study is aimed at assessing poly(styrene-block-isobutylene-block-styrene) (SIBS) properties and comparing them with polytetrafluoroethylene (Gore-texTM, a reference sample). Surface topography of both materials was evaluated with scanning electron microscopy and atomic force microscopy. The mechanical properties were measured under uniaxial tension. The water contact angle was estimated to evaluate hydrophilicity/hydrophobicity of the study samples. Materials’ hemocompatibility was evaluated using cell lines (Ea.hy 926), donor blood, and in vivo. SIBS possess a regular surface relief. It is hydrophobic and has lower strength as compared to Gore-texTM (3.51 MPa vs. 13.2/23.8 MPa). SIBS and Gore-texTM have similar hemocompatibility (hemolysis, adhesion, and platelet aggregation). The subcutaneous rat implantation reports that SIBS has a lower tendency towards calcification (0.39 mg/g) compared with Gore-texTM (1.29 mg/g). SIBS is a highly hemocompatible material with a promising potential for manufacturing heart valve leaflets, but its mechanical properties require further improvements. The possible options include the reinforcement with nanofillers and introductions of new chains in its structure.