Mohamed Abdelkarim Abdelbaky

Dr. Mohamed Abdelkarim Abdelbaky

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2021 in IEEE Access
Verified
Journal Article
Open access
Mishkat JanMishkat Jan
Mishkat Jan
XAXin Ai
Xin Ai
HRHaseeb Ur Rehman
Haseeb Ur Rehman
MAMohamed Abdelkarim Abdelbaky
Mohamed Abdelkarim Abdelbaky
Sheeraz IqbalSheeraz Iqbal
Sheeraz Iqbal
MAMuhammad Aurangzeb
Muhammad Aurangzeb
Energy storage system (ESS) possesses tremendous potential to counter both the rapid growth of intermittent renewable energy resources (RESs) and provide frequency support to the microgrid (MG). Since the deployment of ESS has overcome the imbalance between generation and consumption, however, their massive cost, as well as degradation tendency, are the restricting considerations that demand alternative solutions to provide stable microgrid operation. To assist ESS, the electric vehicles (EVs) are incorporated into the system. EVs have been gradually commercially viable and considerable focus has been paid to vehicle-to-grid technologies. Appropriate collaboration between ESS and EVs has good capability to manage the frequency irregularities to ensure the efficient operation of the MG. This article presents a novel combination of two control techniques i.e., model predictive control (MPC) and adaptive droop control (ADC), to tackle the frequency regulation issue in the isolated MG, by effectively controlling the ESS and EVs during the large-scale integration of RESs or huge change in load demand. Firstly, the MPC regulates the ESS according to the system frequency deviation, and secondly, the ADC manages the power of EVs according to system specifications by retaining the least possible power for potential usage of EVs. Moreover, an advanced genetic algorithm is applied to tune the MPC and ADC parameters in order to achieve optimized performance. An isolated MG is modeled and verified in MATLAB/Simulink using the above-mentioned control techniques. Further, different case studies are taken into account to validate the combination of ADC and MPC for frequency regulation of an isolated MG. Additionally, the proposed MPC controller is compared with fuzzy logic proportional-integral (FPI) controller and proportional-integral (PI) controller, the MPC provides better performance results as compared with FPI and PI controllers.

7 May 2020 in IEEE Access
Verified
Journal Article
Open access
Mishkat JanMishkat Jan
Mishkat Jan
XAXin Ai
Xin Ai
MAMohamed Abdelkarim Abdelbaky
Mohamed Abdelkarim Abdelbaky
HRHaseeb Ur Rehman
Haseeb Ur Rehman
Sheeraz IqbalSheeraz Iqbal
Sheeraz Iqbal
The number of electric vehicles and renewable energy resources integrated into the power system is increasing day by day. The objective behind the development of electric vehicles and renewable energy sources is to build a sustainable and green power system. The renewables either don't possess system inertia or have less system inertia, therefore, they don’t effectively respond to the load variations. The battery storage system of electric vehicles is used as the first line of defense to counter the effect of load/frequency variations and make the system stable. As active power is inversely proportional to the system frequency, for this purpose electric vehicles are included in the microgrid environment. In this paper, an isolated microgrid having a reheat turbine system, wind turbine system, photovoltaic system, and electric vehicles is studied. The output of the renewables is not controlled to utilize its maximum output power. Therefore, adaptive droop control and fuzzy PI control mechanisms are implemented to cater to the frequency variations of the isolated microgrid; the former regulates the power of electric vehicles while maintaining the energy needs of each EV and the later controls the output power of reheat turbine system according to the frequency variation. Furthermore, the genetic algorithm optimization toolbox is utilized to optimize the parameters of the adaptive and fuzzy PI controllers. The proposed model is developed in MATLAB/Simulink which shows that these control techniques effectively sustained the system frequency of isolated microgrid in the desired limits.

1 February 2021 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
HRHaseeb Ur Rehman
Haseeb Ur Rehman
XYXiangwu Yan
Xiangwu Yan
MAMohamed Abdelkarim Abdelbaky
Mohamed Abdelkarim Abdelbaky
MJMishkat Ullah Jan
Mishkat Ullah Jan
SISheeraz Iqbal
Sheeraz Iqbal

1 January 2020 in Renewable Energy
Verified
Journal Article
Closed access
MAMohamed Abdelkarim Abdelbaky
Mohamed Abdelkarim Abdelbaky
XLXiangjie Liu
Xiangjie Liu
DJDi Jiang
Di Jiang

3 August 2020 in IEEE Access
Verified
Journal Article
Open access
Sheeraz IqbalSheeraz Iqbal
Sheeraz Iqbal
XAXin Ai
Xin Ai
Mishkat JanMishkat Jan
Mishkat Jan
MAMohamed Abdelkarim Abdelbaky
Mohamed Abdelkarim Abdelbaky
HRHaseeb Ur Rehman
Haseeb Ur Rehman
MAMuhammad Aurangzeb
Muhammad Aurangzeb
After nearly a century with internal combustion engines dominating the transportation sector, it now appears that electric vehicles (EVs) are on the brink of enjoying rapid development due to numerous useful features they possess, such as less operational cost and reduced carbon emissions. EVs can act as load as well as source, by utilizing the technique known as Vehicle-to-Grid (or Grid-to-Vehicle technique if EVs are used as a load). This technique adds key features to an industrial microgrid in the form of primary frequency control and congestion management. In this paper, two controllers (grid regulation and charger controller) are proposed by considering different charging profiles, state of charge of electric vehicle batteries, and a varying number of electric vehicles in an electric vehicle fleet. These controllers provide bidirectional power flow, which can provide primary frequency control during different contingencies that an industrial microgrid may face during a 24-hour period. Simulation results prove that the proposed controllers provide reliable support in terms of frequency regulation to an industrial microgrid during contingencies. Furthermore, simulation results also depict that by adding more electric vehicles in the fleet during the vehicle-to-grid mode, the frequency of an industrial microgrid can be improved to even better levels. Different case studies in this article constitute an industrial microgrid with varied distributed energy resources (i.e. solar and wind farm), electric vehicles fleet, industrial and residential load along with diesel generator. These test cases are simulated and results are analyzed by using MATLAB/SIMULINK.

25 March 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Sheeraz IqbalSheeraz Iqbal
Sheeraz Iqbal
XAXin Ai
Xin Ai
Mishkat JanMishkat Jan
Mishkat Jan
SSSalman Salman
Salman Salman
AZAtta Ul Munim Zaki
Atta Ul Munim Zaki
MAMohamed Abdelkarim Abdelbaky
Mohamed Abdelkarim Abdelbaky
Electric vehicles (EVs) have been receiving greater attention as a tool for frequency control due to their fast regulation capability. The proliferation of EVs for primary frequency regulation is hampered by the need to simultaneously maintain industrial microgrids dispatch and EV state of charge levels. The current research aims to examine the operative and dominating role of the charging station operator, along with a vehicle to grid strategy; where, indeterminate tasks are executed in the microgrid without the EVs charging/discharging statistics. The role of the charging station operator in regulation is the assignment of the job inside the primary frequency control capacity of electric vehicles. Real-time rectification of programmed vehicle to grid (V2G) power ensures electric vehicles’ state of charge at the desired levels. The proposed V2G strategy for primary frequency control is validated through the application of a two-area interconnected industrial micro-grid and another microgrids with renewable resources. Regulation specifications are communicated to electric vehicles and charging station operators through an electric vehicle aggregator in the proposed strategy. At the charging station operator, V2G power at the present time is utilized for frequency regulation capacity calculation. Subsequently, the V2G power is dispatched in light of the charging demand and the frequency regulation. Furthermore, V2G control strategies for distribution of regulation requirement to individual EVs are also developed. In summary, the article presents a novel primary frequency control through V2G strategy in an industrial microgrid, involving effective coordination of the charging station operator, EV aggregator, and EV operator.