Rotating machines are exposed to different faults such as shaft cracks, bearing failures, rotor misalignment, stator to rotor rub, etc. Therefore, turbo-generators, aircraft engines, compressors, pumps, and many other rotating machines should be constantly diagnosed to warn about the probable appearance of a possible rotor failure. Unfortunately, despite the ongoing work on various rotor fault detection methods, there are still very few techniques that can be considered as reliable and applicable in practical problems. The difficulty lies in the fact that usually the fault introduces very subtle local changes in the overall structure of the rotor. The symptoms of these changes must be isolated and extracted from a wide spectrum of vibration data obtained from sensors measuring the vibrations of the machine. The measured data are usually disturbed with some noise or other disturbances, and that is why the detection of a possible rotor fault is even more difficult. The paper presents a new rotor fault detection method. The method is based on a new diagnostic model of rotor signals and external disturbances. The model utilizes auto-correlation functions of measured rotor’s vibrations. By proper processing of the measured vibration data, the influence of environmental disturbances is completely compensated and reliable indications of the possible rotor fault are obtained. The method has been tested numerically using the finite element model of the rotor and then verified experimentally at the shaft crack detection test rig. The results are presented in a readable graphical form and confirm high sensitivity and reliability of the method.
23 February 2023 in Mechanical Systems and Signal Processing
In this work, an innovative diagnosis method of rotor blades is presented. A measurement signal of blade tip displacement is divided into two observation zones, in which two peaks of an additional template signal are introduced. Cross‐correlation and power spectral density functions of the measurement and template signals in these two distinct zones are calculated. Next, the phase shift between the two cross‐correlation functions is obtained by calculating the ratio of the two power spectral density functions. The changes in parameters of an analytical description of this phase shift are used to determine a distinct and easy‐to‐analyze image of the technical condition of the tested blade. A graphical portrait indicating the technical condition of all blades in the annulus is developed. Although not directly measured, environmental signals (e.g., external disturbances and sensor’s noise) affecting the diagnostic process are included in the method. It is demonstrated that, by using the proposed signal processing technique, a negative influence of these disturbances is eliminated and the reliability of the machine technical condition indications is improved. The approach is demonstrated using experimental results of turbine engine blade displacements. High effectiveness of the method and measurement equipment has been confirmed in a wide range of analyzed tip‐timing results obtained in different periods of the measurement process.
In this article was presented an auto calibration algorithm based on a two-step regulator and gyroscope readings. Unable to use PID, as the PWM signal causes the motors to overheat, it was decided to introduce a two-step algorithm. This type of controller reaches the setpoint much faster, though an error is present. Gyroscope is used to sample angular speed and then integrate these values to get the angle. To calibrate the offsets the robot performs a calibration run during which it measures and averages the error on each gyroscope axis while no movement is present. Afterwards it makes a characteristics of braking angle and angular speed. Interpolated polynomial from 13 samples allows to designate the point in time where the braking has to start to achieve the desired angle. The calibration aims for adjusting the parameters of movement depending on the surface it runs on. Additional check is made using encoders to estimate the accuracy of gyroscope output.
The article presents an adaptation of a parametric diagnostic method based on the square of the amplitude gains model, which was tested in experimental studies on bearing damage detection (outer race, inner race, bearing balls damage). The described method is based on the shaft displacement signal analysis, which is affected by vibrations coming from the bearings. The diagnostic model’s parameters are determined by processing the signal from the time domain to the frequency domain in a few steps. Firstly, the recorded signal is divided into two observation periods, next the analytical autocorrelation functions are determined and approximated by a polynomial. Then, the diagnostic thresholds are adopted, and the model parameters are converted into damage maps that are easy to interpret and assess the technical condition of the bearings. The presented method shows the technical condition of bearings in a qualitative way. Depending on the received color damage maps, it is possible to determine their level of wear. Green and blue indicate poor wear or no damage, red indicates increased wear, and black clearly indicates a damaged bearing.
In the article, new method of monitoring of rotor machine blades technical condition is presented. This method is based on diagnostic model φT12T01 [ which uses phase shift difference of signal fragments resulting from blade operation y (t) during blade recession from sensor and during approach of blade tip towards the sensor as well as signal of its environment x (t) described using proper distribution. The assumed diagnostic model also indirectly includes actual blade environment x (t) without necessity of its measurement [3,. Contactless inductive sensor constantly measures the signal of operating blade transition below the sensor. However, several difficulties with determination of last sample of blade receding from the sensor with first sample of blade approaching the sensor exist. Additionally the problem occurs with measurement of space between blades. So far, the case was solved by use 90% of this space range (in order to eliminate the overlapping of adjacent blades signals). Hence the problem of assessment of measurement period breadth on obtained models (images) of blades. The possibility of blade damage detection by analysis of less than 90% signal course was tested.