A dilution tunnel was designed for the characterization of brake-wear particle emissions up to 10 μm on a brake dyno. The particulate matter emission levels from a single front brake were found to be 4.5 mg/km (1.5 mg/km being smaller than 2.5 μm) over a novel real-world brake cycle, for a commercial Economic Commission for Europe (ECE) pad. Particle Number (PN) emissions as defined in exhaust regulations were in the order of 1.5 to 6 × 109 particles per km per brake (#/km/brake). Concentration levels could exceed the linearity range of full-flow Condensation Particle Counters (CPCs) over specific braking events, but remained at background levels for 60% of the cycle. Similar concentrations measured with condensation and optical counters suggesting that the majority of emitted particles were larger the 300 nm. Application of higher braking pressures resulted in elevated PN emissions and the systematic formation of nano-sized particles that were thermally stable at 350 °C. Volatile particles were observed only during successive harsh braking events leading to elevated temperatures. The onset depended on the type of brakes and their prehistory, but always at relatively high disc temperatures (280 to 490 °C).
The particle number (PN) emissions of vehicles equipped with particulate filters are low. However, there are technologies that can have high PN levels, especially below the currently lower regulated particle size of 23 nm. Sub-23-nm particles are also considered at least as dangerous as the larger ultrafine particles. For this reason, the European Union (EU) is planning to regulate particles down to 10 nm. In this study we compared prototype portable emission measurement systems (PEMS) and reference laboratory systems measuring from 10 nm. The tests included cycles and constant speeds, using vehicles fuelled with diesel, gasoline or liquefied petroleum gas (LPG). The results showed that the PEMS were within ±40% of the reference systems connected to the tailpipe and the dilution tunnel. Based on the positive findings and the detection efficiencies of the prototype instruments, a proposal for the technical specifications for the future regulation was drafted.
On-board portable emissions measurement systems (PEMS) are part of the type approval, in-service conformity, and market surveillance aspects of the European exhaust emissions regulation. Currently, only solid particles >23 nm are counted, but Europe will introduce a lower limit of 10 nm. In this study, we evaluated a 10-nm prototype portable system comparing it with laboratory systems measuring diesel, gasoline, and CNG (compressed natural gas) vehicles with emission levels ranging from approximately 2 × 1010 to 2 × 1012 #/km. The results showed that the on-board system differed from the laboratory 10-nm system on average for the tested driving cycles by less than approximately 10% at levels below 6 × 1011 #/km and by approximately 20% for high-emitting vehicles. The observed differences were similar to those observed in the evaluation of portable >23 nm particle counting systems, despite the relatively small size of the emitted particles (with geometric mean diameters 10 nm on-board systems can be ready for introduction in future regulations.
The particle emissions from a commercial brake system utilizing copper-free pads have been characterized on a brake dynamometer under two real-world driving cycles. These included a novel cycle developed from analysis of the database of the World Harmonized Test Procedure (WLTP-Brake) and a short version of the Los Angeles City Traffic cycle (3h-LACT) developed in the framework of the European LowBraSys project. Disc temperature measurements using an array of embedded thermocouples revealed a large temporal and spatial non-uniformity with the radial temperature distribution depending also on the test procedure. Averaging over the duration of the cycle, it effectively reduced the influence of thermocouple positioning, allowing for more reliable quantification of the effectiveness of convective cooling. Particulate Matter (PM) emissions were similar for both cycles with PM2.5 averaging at 2.2 (±0.2) mg/km over the WLTP-Brake and 2.2 (±0.2) mg/km over the 3h-LACT, respectively. The corresponding PM10 emissions were 5.6 (±0.2) mg/km and 8.6 (±0.7) mg/km, respectively. The measurements revealed the formation of nanosized particles peaking at 10 nm, which were thermally stable at 350 °C under both cycles. Volatile nanoparticles were observed over the more demanding 3h-LACT cycle, with their emission rates decreasing with increasing the tunnel flow, suggesting nucleation of organic vapors released during braking as a potential formation process.
12 February 2016 in Aerosol Science and Technology
Onboard measurement of non-volatile particle number (PN) emissions with portable emissions measurement systems (PEMS) was introduced for the type-approval of passenger cars in Europe since 2017 and is foreseen for heavy-duty (HD) vehicles in 2021. First studies on the performance of PN-PEMS with HD engine exhaust revealed larger differences between established PN-PEMS techniques than what was observed for passenger cars. Particles forming in selective catalytic reduction (SCR) systems for NOx of late technology HD engines have recently been identified as a potential reason for the observed differences. The formed particles have a size distribution peaking below the regulatory limit of 23 nm and most importantly acquire high (more than one) positive charges at the elevated exhaust temperatures. Precise measurement of such highly charged nanosized particles with PN-PEMS instrumentation utilizing diffusion charger (DC) based counters requires proper conditioning of these charges. Two approaches were investigated in this study: (a) an electrofilter (EF) to completely remove charged particles below the regulated size and (b) a tandem negative-positive corona (TC) charger to directly condition pre-charged particles. The two technical solutions were tested alongside the unmodified DC-based PN-PEMS, a PN-PEMS utilizing a condensation particle counter (CPC) and a reference stationary PN system using exhaust of two SCR-equipped HD engines. The results confirmed that the particles forming in such SCR systems are responsible for the observed inconsistencies and that both technical solutions efficiently address the interferences of these pre-charged nanoparticles.