Brake wear emissions with a special focus on particle number (PN) concentrations were investigated during a chassis dynamometer measurement campaign. A recently developed, well-characterized, measurement approach was applied to measure brake particles in a semi-closed vehicle setup. Implementation of multiple particle measurement devices allowed for simultaneous measurement of volatile and solid particles. Estimated PN emission factors for volatile and solid particles differed by up to three orders of magnitude with an estimated average solid particle emission factor of 3∙109 # km−1 brake−1 over a representative on-road brake cycle. Unrealistic high brake temperatures may occur and need to be ruled out by comparison with on-road temperature measurements. PN emissions are strongly temperature dependent and this may lead to its overestimation. A high variability for PN emissions was found when volatile particles were not removed. Volatiles were observed under high temperature conditions only which are not representative of normal driving conditions. The coefficient of variation for PN emissions was 1.3 without catalytic stripper and 0.11 with catalytic stripper. Investigation of non-braking sections confirmed that particles may be generated at the brake even if no brakes are applied. These “off-brake-event” emissions contribute up to about 30% to the total brake PM10 emission.
3 March 2010 in Environmental Science & Technology
In the European Union's emissions regulations, limits for solid particles >23 nm are applicable for the type-approval and in use compliance of vehicles. Consequently, particle number (PN) systems are used very often for both research and development of engines and vehicles, both in the laboratory and on the road. The technical specifications of the laboratory and portable on-board systems are not the same resulting in different measurement uncertainties. Furthermore, particles, in contrast to gases, can be lost in the transfer lines making comparisons at different sampling locations difficult. Moreover, the size dependent counting efficiency of the systems can result in high discrepancies when the measured particle sizes are close to the decreasing steep part of the curves. The different sampling locations (tailpipe or dilution tunnel) and thermal pretreatments of the aerosol further enhance the differences. The studies on the measurement uncertainty are scarce, especially for the PN systems measuring from 10 nm that will be introduced in the future regulations. This study quantified the uncertainty sources of the PN systems: (i) due to the technical requirements and the calibrations, (ii) due to the unknown particle sizes during measurement, (iii) due to particle losses from the vehicle to the PN systems at the tailpipe or the dilution tunnel, (iv) other parameters needed for the calculation of the emissions, non-related to the PN systems, e.g. flow and distance. The expanded uncertainty of the 23 nm laboratory systems sampling from the dilution tunnel was estimated to be 32%, with 18% originating from the calibration procedures, while of those sampling from the tailpipe 34%. For the 23 nm portable systems measuring on-road the uncertainty was 39%. The values were 2-8% higher for the 10 nm systems.
Vehicle regulations include limits for non-volatile particle number emissions with sizes larger than 23 nm. The measurements are conducted with systems that remove the volatile particles by means of dilution and heating. Recently, the option of measuring from 10 nm was included in the Global Technical Regulation (GTR 15) as an additional option to the current >23 nm methodology. In order to avoid artefacts, i.e., measuring volatile particles that have nucleated downstream of the evaporation tube, a heated oxidation catalyst (i.e., catalytic stripper) is required. This review summarizes the studies with laboratory aerosols that assessed the volatile removal efficiency of evaporation tube and catalytic stripper-based systems using hydrocarbons, sulfuric acid, mixture of them, and ammonium sulfate. Special emphasis was given to distinguish between artefacts that happened in the 10–23 nm range or below. Furthermore, studies with vehicles’ aerosols that reported artefacts were collected to estimate critical concentration levels of volatiles. Maximum expected levels of volatiles for mopeds, motorcycles, light-duty and heavy-duty vehicles were also summarized. Both laboratory and vehicle studies confirmed the superiority of catalytic strippers in avoiding artefacts. Open issues that need attention are the sulfur storage capacity and the standardization of technical requirements for catalytic strippers.
The particle number (PN) emissions of vehicles equipped with particulate filters are low. However, there are technologies that can have high PN levels, especially below the currently lower regulated particle size of 23 nm. Sub-23-nm particles are also considered at least as dangerous as the larger ultrafine particles. For this reason, the European Union (EU) is planning to regulate particles down to 10 nm. In this study we compared prototype portable emission measurement systems (PEMS) and reference laboratory systems measuring from 10 nm. The tests included cycles and constant speeds, using vehicles fuelled with diesel, gasoline or liquefied petroleum gas (LPG). The results showed that the PEMS were within ±40% of the reference systems connected to the tailpipe and the dilution tunnel. Based on the positive findings and the detection efficiencies of the prototype instruments, a proposal for the technical specifications for the future regulation was drafted.