Distributed cutaneous tissue blood volume oscillations contain information on autonomic nervous system (ANS) regulation of cardiorespiratory activity as well as dominating thermoregulation. ANS associated with low-frequency oscillations can be quantified in terms of frequencies, amplitudes, and phase shifts. The relative order between these faculties may be disturbed by conditions colloquially termed ‘stress’. Photoplethysmography imaging, an optical non-invasive diagnostic technique provides information on cutaneous tissue perfusion in the temporal and spatial domains. Using the cold pressure test (CPT) in thirteen healthy volunteers as a well-studied experimental intervention, we present a method for evaluating phase shifts in low- and intermediate frequency bands in forehead cutaneous perfusion mapping. Phase shift changes were analysed in low- and intermediate frequency ranges from 0.05 Hz to 0.18 Hz. We observed that time waveforms increasingly desynchronised in various areas of the scanned area throughout measurements. An increase of IM band phase desynchronization observed throughout measurements was comparable in experimental and control group, suggesting a time effect possibly due to overshooting the optimal relaxation duration. CPT triggered an increase in the number of points phase-shifted to the reference that was specific to the low frequency range for phase-shift thresholds defined as π/4, 3π/8, and π/2 rad, respectively. Phase shifts in forehead blood oscillations may infer changes of vascular tone due to activity of various neural systems. We present an innovative method for the phase shift analysis of cutaneous tissue perfusion that appears promising to assess ANS change processes related to physical or psychological stress. More comprehensive studies are needed to further investigate the reliability and physiological significance of findings.
This article introduces a two-electrode ground-free electrocardiogram (ECG) with minimal hardware complexity, which is ideal for wearable battery-powered devices. The main issue of ground-free measurements is the presence of noise. Therefore, noise suppression methods that can be employed for a two-electrode ECG acquisition system are discussed in detail. Experimental measurements of a living subject and patient simulator are used to investigate and compare the performance of the three proposed methods utilizing the ADS1191 analogue front-end for biopotential measurements. The resulting signals recorded for the simulator indicate that all three methods should be suitable for suppressing power-line noise. The Power Spectral Density (PSD) of the signals measured for a subject exhibits differences across methods; the signal power at 50 Hz is −28, −24.8, and −26 dB for the first, second, and third method, respectively. The digital postprocessing of measured signals acquired a high-quality ECG signal comparable to that of three-electrode sensing. The current consumption measurements demonstrate that all proposed two-electrode ECG solutions are appropriate as a battery-powered device (current consumption < 1.5 mA; sampling rate of 500 SPS). The first method, according to the results, is considered the most effective method in the suppression of power-line noise, current consumption, and hardware complexity.
A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common-mode voltage at the input terminals of the acquisition unit. The origin and methods of noise reduction are described on electric models. Two methods of noise removal are modeled and experimentally verified in the paper. The first method uses a passive capacitive grounding electrode, and the second uses an active capacitive Driven Right Leg (DRL) electrode. The effect of grounding electrode size on noise suppression is experimentally investigated. The increasing electrode area reduces power-line noise: the power of power-line frequency within the measured signal is 70.96 dB, 59.13 dB, and 43.44 dB for a grounding electrode area of 1650 cm2, 3300 cm2, and 4950 cm2, respectively. The capacitive DRL electrode shows better efficiency in common-mode noise rejection than the grounding electrode. When using an electrode area of 1650 cm2, the DRL achieved 46.3 dB better attenuation than the grounding electrode at power-line frequency. In contrast to the grounding electrode, the DRL electrode reduces a capacitive measurement system’s financial costs due to the smaller electrode area made of the costly conductive textile.
Objective: Photoplethysmography Imaging (PPGI) is a promising contactless camera-based method of non-invasive cardiovascular diagnostics. To achieve the best results, it is important to choose the most suitable camera for a specific application. The settings of the camera influence the quality of the detected signal. Approach: The standard (EMVA 2016) for evaluating the imaging performance of machine vision cameras (MVC) helps at the initial decision of the sensor, but the camera should always be tested in terms of usability for a specific application. So far, PPGI lacks a standardized measurement scenario for evaluating the performance of individual cameras. For this, we realized a controllable optoelectronic phantom with artificial silicone skin allowing reproducible tests of cameras to verify their suitability for PPGI. The entire system is housed in a light-tight box. We tested an MVC, a digital single-lens reflex camera (DSLR) camera and a webcam. Each camera varies in used technology and price. Main results: We simulated real PPGI measurement conditions simulating the ratio of pulse (AC) and non-pulse (DC) component of the photoplethysmographic signal and achieved AC/DC ratios of 0.5% on average. An additional OLED panel ensures proper DC providing reproducible measurement conditions. We evaluated the signal morphological features, amplitude spectrum, signal-to-noise ratio (SNR) and spatially dependent changes of simulated subcutaneous perfusion. Here, the MVC proved to be the most suitable device. A DSLR is also suitable for PPGI, but a larger smoothing kernel is required to obtain a perfusion map. The webcam, as the weakest contender, proved to be very susceptible to any inhomogeneous illumination of the examined artificial skin surface. However, it is still able to detect cardiac rhythm. Significance: The result of our work is an optoelectronic phantom for reproducible testing of PPGI camera performance in terms of signal quality and measurement equipment costs.
In today’s neonatal intensive care units, monitoring vital signs such as heart rate and respiration is fundamental for neonatal care. However, the attached sensors and electrodes restrict movement and can cause medical-adhesive-related skin injuries due to the immature skin of preterm infants, which may lead to serious complications. Thus, unobtrusive camera-based monitoring techniques in combination with image processing algorithms based on deep learning have the potential to allow cable-free vital signs measurements. Since the accuracy of deep-learning-based methods depends on the amount of training data, proper validation of the algorithms is difficult due to the limited image data of neonates. In order to enlarge such datasets, this study investigates the application of a conditional generative adversarial network for data augmentation by using edge detection frames from neonates to create RGB images. Different edge detection algorithms were used to validate the input images’ effect on the adversarial network’s generator. The state-of-the-art network architecture Pix2PixHD was adapted, and several hyperparameters were optimized. The quality of the generated RGB images was evaluated using a Mechanical Turk-like multistage survey conducted by 30 volunteers and the FID score. In a fake-only stage, 23% of the images were categorized as real. A direct comparison of generated and real (manually augmented) images revealed that 28% of the fake data were evaluated as more realistic. An FID score of 103.82 was achieved. Therefore, the conducted study shows promising results for the training and application of conditional generative adversarial networks to augment highly limited neonatal image datasets.
1 January 2016 in Journal of Electrical Engineering
Wireless communication eliminates obtrusive cables associated with wearable sensors and considerably increases patient comfort during measurement and collection of medical data. Wireless communication is very popular in recent years and plays a significant role in telemedicine and homecare applications. Bluetooth technology is one of the most commonly used wireless communication types in medicine. This paper describes the design of a universal wireless communication device with excellent price/performance ratio. The said device is based on the low-cost RN4020 Bluetooth module with Microchip Low-energy Data Profile (MLDP) and due to low-power consumption is especially suitable for the transmission of biological signals (ECG, EMG, PPG, etc.) from wearable medical/personal health devices. A unique USB dongle adaptor was developed for wireless communication via UART interface and power consumption was evaluated under various conditions.