There is a growing interest in using additive manufacturing to produce smart structures, which have the capability to respond to thermal and mechanical stimuli. In this report, Selective Laser Melting (SLM) is used to build a Negative Poisson's Ratio (NPR) TiNi-based Shape Memory Alloy (SMA) structure, creating a multi-functional structure that could be used as reusable armour. The study assesses the influence of SLM process parameters (laser power, scan speed, and track spacing) on the microstructural and structural integrity development in a Ti-rich TiNi alloy, as well as the impact of the post-process homogenisation treatment on the microstructure and phase transformations. The builds generally shows stress-induced cracks and residual porosity, which could be minimised through process optimisation. Nonetheless, the homogenisation treatment is essential to reduce the fraction of Ti2Ni intermetallics, which are known to disturb the B19′-chemistry, and hence the required phase transformation temperatures. The optimum process parameters are finally used to fabricate NPR structures, which were mechanically tested to validate the Poisson's ratio predictions. A higher ductility was observed in the structures that have undergone the homogenisation treatment
The main challenge associated with the application of selective laser melting (SLM) to Ni based superalloys is the performance of process optimisation to maximise the mechanical properties. The energy density parameter has typically been used as a semiquantitative approach to identify the energy threshold beyond which the material achieves virtually full consolidation. Nonetheless, some Ni superalloys are susceptible to crack formation during SLM, which cannot be avoided via process optimisation. In the present report, a comparative study is presented showing the utility of the energy density parameter in process optimisation for γ′ and γ′/γ″ strengthened Ni based superalloys. For both classes, it was found that the build density increases [i.e. void area () decreases] with the increase in the energy density. Nonetheless, no direct correlation can be found between the energy density parameter and the cracking density.
1 August 2021 in International Journal of Machine Tools and Manufacture
Purpose: Ti6Al4V alloy has received a great deal of attention in medical applications due to its biomechanical compatibility. However, the human bone stiffness is between 10 and 30 GPa while solid Ti6Al4V is several times stiffer, which would cause stress shielding with the surrounding bone, which can lead to implant and/or the surrounding bone’s failure. Design/methodology/approach: In this work, the effect of selective laser melting (SLM) process parameters on the characteristics of Ti6Al4V samples, such as porosity level, surface roughness, elastic modulus and compressive strength (UCS), has been investigated using response surface method. The examined ranges of process parameters were 35-50 W for laser power, 100-400 mm/s for scan speed and 35-120 µm for hatch spacing. The process parameters have been optimized to obtain structures with properties very close to that in human bones. Findings: The results showed that the porosity percentage of a SLM component could be increased by reducing the laser power and/or increasing the scan speed and hatch spacing. It was also shown that there was a reverse relationship between the porosity level and both the modulus of elasticity and UCS of the SLM part. In addition, the increased laser power was resulted into a substantial decrease of the surface roughness of SLM parts. Results from the optimization study revealed that the interaction between laser process parameters (i.e. laser power, laser speed, and the laser spacing) have the most significant influence on the mechanical properties of fabricated samples. The optimized values for the manufacturing of medical implants were 49 W, 400 mm/s and 99 µm for the laser power, laser speed and laser spacing, respectively. The corresponding porosity, surface roughness, modulus of elasticity and UCS were 23.62 per cent, 8.68 µm, 30 GPa and 522 MPa, respectively. Originality/value: Previous investigations related to additive manufacturing of Ti alloys have focused on producing fully dense and high-integrity structures. There is a clear gap in literature regarding the simultaneous enhancement and adjustment of pore fraction, surface and mechanical properties of Ti6Al4V SLM components toward biomedical implants. This was the objective of the current study.