Lukas Adamowicz

Mr. Lukas Adamowicz

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2022 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
LALukas Adamowicz
Lukas Adamowicz
YCYiorgos Christakis
Yiorgos Christakis
MCMatthew Daniel Czech
Matthew Daniel Czech
TATomasz Adamusiak
Tomasz Adamusiak
Wearable inertial sensors are providing enhanced insight into patient mobility and health. Significant research efforts have focused on wearable algorithm design and deployment in both research and clinical settings; however, open-source, general-purpose software tools for processing various activities of daily living are relatively scarce. Furthermore, few studies include code for replication or off-the-shelf software packages. In this work, we introduce SciKit Digital Health (SKDH), a Python software package (Python Software Foundation) containing various algorithms for deriving clinical features of gait, sit to stand, physical activity, and sleep, wrapped in an easily extensible framework. SKDH combines data ingestion, preprocessing, and data analysis methods geared toward modern data science workflows and streamlines the generation of digital endpoints in “good practice” environments by combining all the necessary data processing steps in a single pipeline. Our package simplifies the construction of new data processing pipelines and promotes reproducibility by following a convention over configuration approach, standardizing most settings on physiologically reasonable defaults in healthy adult populations or those with mild impairment. SKDH is open source, as well as free to use and extend under a permissive Massachusetts Institute of Technology license, and is available from GitHub (PfizerRD/scikit-digital-health), the Python Package Index, and the conda-forge channel of Anaconda.

24 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LALukas Adamowicz
Lukas Adamowicz
RGReed Gurchiek
Reed Gurchiek
JFJonathan Ferri
Jonathan Ferri
AUAnna T. Ursiny
Anna T. Ursiny
NFNiccolo Fiorentino
Niccolo Fiorentino
Ryan McginnisRyan Mcginnis
Ryan Mcginnis
Wearable sensor-based algorithms for estimating joint angles have seen great improvements in recent years. While the knee joint has garnered most of the attention in this area, algorithms for estimating hip joint angles are less available. Herein, we propose and validate a novel algorithm for this purpose with innovations in sensor-to-sensor orientation and sensor-to-segment alignment. The proposed approach is robust to sensor placement and does not require specific calibration motions. The accuracy of the proposed approach is established relative to optical motion capture and compared to existing methods for estimating relative orientation, hip joint angles, and range of motion (ROM) during a task designed to exercise the full hip range of motion (ROM) and fast walking using root mean square error (RMSE) and regression analysis. The RMSE of the proposed approach was less than that for existing methods when estimating sensor orientation ( 12.32 ° and 11.82 ° vs. 24.61 ° and 23.76 ° ) and flexion/extension joint angles ( 7.88 ° and 8.62 ° vs. 14.14 ° and 15.64 ° ). Also, ROM estimation error was less than 2.2 ° during the walking trial using the proposed method. These results suggest the proposed approach presents an improvement to existing methods and provides a promising technique for remote monitoring of hip joint angles.

19 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LALukas Adamowicz
Lukas Adamowicz
FKF. Isik Karahanoglu
F. Isik Karahanoglu
CCChristopher Cicalo
Christopher Cicalo
HZHao Zhang
Hao Zhang
CDCharmaine Demanuele
Charmaine Demanuele
SPShyamal Patel
Shyamal Patel
The ability to perform sit-to-stand (STS) transfers has a significant impact on the functional mobility of an individual. Wearable technology has the potential to enable the objective, long-term monitoring of STS transfers during daily life. However, despite several recent efforts, most algorithms for detecting STS transfers rely on multiple sensing modalities or device locations and have predominantly been used for assessment during the performance of prescribed tasks in a lab setting. A novel wavelet-based algorithm for detecting STS transfers from data recorded using an accelerometer on the lower back is presented herein. The proposed algorithm is independent of device orientation and was validated on data captured in the lab from younger and older healthy adults as well as in people with Parkinson’s disease (PwPD). The algorithm was then used for processing data captured in free-living conditions to assess the ability of multiple features extracted from STS transfers to detect age-related group differences and assess the impact of monitoring duration on the reliability of measurements. The results show that performance of the proposed algorithm was comparable or significantly better than that of a commercially available system (precision: 0.990 vs. 0.868 in healthy adults) and a previously published algorithm (precision: 0.988 vs. 0.643 in persons with Parkinson’s disease). Moreover, features extracted from STS transfers at home were able to detect age-related group differences at a higher level of significance compared to data captured in the lab during the performance of prescribed tasks. Finally, simulation results showed that a monitoring duration of 3 days was sufficient to achieve good reliability for measurement of STS features. These results point towards the feasibility of using a single accelerometer on the lower back for detection and assessment of STS transfers during daily life. Future work in different patient populations is needed to evaluate the performance of the proposed algorithm, as well as assess the sensitivity and reliability of the STS features.

18 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
WLWenyi Lin
Wenyi Lin
FKFikret Isik Karahanoglu
Fikret Isik Karahanoglu
DPDimitrios John Psaltos
Dimitrios John Psaltos
LALukas Adamowicz
Lukas Adamowicz
MSMar Santamaria
Mar Santamaria
JDJunrui Di
Junrui Di
Wearable accelerometers allow for continuous monitoring of function and behaviors in the participant’s naturalistic environment. Devices are typically worn in different body locations depending on the concept of interest and endpoint under investigation. The lumbar and wrist are commonly used locations: devices placed at the lumbar region enable the derivation of spatio-temporal characteristics of gait, while wrist-worn devices provide measurements of overall physical activity (PA). Deploying multiple devices in clinical trial settings leads to higher patient burden negatively impacting compliance and data quality and increases the operational complexity of the trial. In this work, we evaluated the joint information shared by features derived from the lumbar and wrist devices to assess whether gait characteristics can be adequately represented by PA measured with wrist-worn devices. Data collected at the Pfizer Innovation Research (PfIRe) Lab were used as a real data example, which had around 7 days of continuous at-home data from wrist- and lumbar-worn devices (GENEActiv) obtained from a group of healthy participants. The relationship between wrist- and lumbar-derived features was estimated using multiple statistical methods, including penalized regression, principal component regression, partial least square regression, and joint and individual variation explained (JIVE). By considering multilevel models, both between- and within-subject effects were taken into account. This work demonstrated that selected gait features, which are typically measured with lumbar-worn devices, can be represented by PA features measured with wrist-worn devices, which provides preliminary evidence to reduce the number of devices needed in clinical trials and to increase patients’ comfort. Moreover, the statistical methods used in this work provided an analytic framework to compare repeated measures collected from multiple data modalities.

27 November 2023 in Frontiers in Digital Health
Verified
Journal Article
Open access
WLWenyi Lin
Wenyi Lin
FKF. Isik Karahanoglu
F. Isik Karahanoglu
CDCharmaine Demanuele
Charmaine Demanuele
SKSheraz Khan
Sheraz Khan
XCXuemei Cai
Xuemei Cai
LALukas Adamowicz
Lukas Adamowicz
Introduction: Accelerometry has become increasingly prevalent to monitor physical activity due to its low participant burden, quantitative metrics, and ease of deployment. Physical activity metrics are ideal for extracting intuitive, continuous measures of participants’ health from multiple days or weeks of high frequency data due to their fairly straightforward computation. Previously, we released an open-source digital health python processing package, SciKit Digital Health (SKDH), with the goal of providing a unifying device-agnostic framework for multiple digital health algorithms, such as activity, gait, and sleep.Methods: In this paper, we present the open-source SKDH implementation for the derivation of activity endpoints from accelerometer data. In this implementation, we include some non-typical features that have shown promise in providing additional context to activity patterns, and provide comparisons to existing algorithms, namely GGIR and the GENEActiv macros. Following this reference comparison, we investigate the association between age and derived physical activity metrics in a healthy adult cohort collected in the Pfizer Innovation Research Lab, comprising 7–14 days of at-home data collected from younger (18–40 years) and older (65–85 years) healthy volunteers.Results: Results showed that activity metrics derived with SKDH had moderate to excellent ICC values (0.550 to 1.0 compared to GGIR, 0.469 to 0.697 compared to the GENEActiv macros), with high correlations for almost all compared metrics (>0.733 except vs GGIR sedentary time, 0.547). Several features show age-group differences, with Cohen’s d effect sizes >1.0 and p-values < 0.001. These features included non-threshold methods such as intensity gradient, and activity fragmentation features such as between-states transition probabilities.Discussion: These results demonstrate the validity of the implemented SKDH physical activity algorithm, and the potential of the implemented PA metrics in assessing activity changes in free-living conditions.

12 December 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
LALukas Adamowicz
Lukas Adamowicz
WLWenyi Lin
Wenyi Lin
FKF Isik Karahanoglu
F Isik Karahanoglu
XCXuemei Cai
Xuemei Cai
MSMar Santamaria
Mar Santamaria
JDJunrui Di
Junrui Di
Background: Digital health technologies, such as accelerometry, offer low participant burden and provide quantitative metrics with ease of deployment, making them increasingly popular for gait monitoring. Remote gait monitoring delivers quantifiable, continuous health measures over extended periods, surpassing the limited insights from single clinic or laboratory visits and offering a more comprehensive health perspective. Numerous gait algorithm implementations, inspired by prior research, aim to standardize these metrics across devices. The SciKit Digital Health (SKDH) package exemplifies this as a device-agnostic framework. Objective: This study introduces a series of literature-informed enhancements to the SKDH gait algorithm, improving its performance against reference standards and reducing the need for manual parameter adjustments across diverse populations. Methods: A block-wise refinement process was undertaken, examining each algorithmic component for potential enhancements and evaluating their cumulative impact on the complete gait algorithm and the metrics generated. Results: Using data from healthy adult and pediatric participants, the novel gait event estimation method reduced the mean absolute error by more than 50% compared with its predecessor. Following the updates, the intraclass correlation values for final gait metric concordance with the in-laboratory reference improved markedly, from 0.50-0.74 to 0.81-0.90. Additionally, the systematic bias observed in the previous version’s gait speed estimation was rectified, narrowing the difference from the reference from 0.065-0.230 to 0.00-0.03 m/s. Conclusions: The findings from this study provide robust evidence supporting the validity of the enhancements made to the gait algorithm. They demonstrate that a single lumbar accelerometer can capture gait characteristics with high accuracy and reliability across various speeds and age groups.