Wearable sensor-based algorithms for estimating joint angles have seen great improvements in recent years. While the knee joint has garnered most of the attention in this area, algorithms for estimating hip joint angles are less available. Herein, we propose and validate a novel algorithm for this purpose with innovations in sensor-to-sensor orientation and sensor-to-segment alignment. The proposed approach is robust to sensor placement and does not require specific calibration motions. The accuracy of the proposed approach is established relative to optical motion capture and compared to existing methods for estimating relative orientation, hip joint angles, and range of motion (ROM) during a task designed to exercise the full hip range of motion (ROM) and fast walking using root mean square error (RMSE) and regression analysis. The RMSE of the proposed approach was less than that for existing methods when estimating sensor orientation ( and vs. and ) and flexion/extension joint angles ( and vs. and ). Also, ROM estimation error was less than during the walking trial using the proposed method. These results suggest the proposed approach presents an improvement to existing methods and provides a promising technique for remote monitoring of hip joint angles.
11 June 2020 in IEEE Journal of Biomedical and Health Informatics
Panic attacks are an impairing mental health problem that affects 11% of adults every year [1]. Those who suffer from panic attacks often do not seek psychological treatment, citing the inability to receive care during their attacks as a contributing factor. A digital medicine solution which provides an accessible, real-time mobile health (mHealth) biofeedback intervention for panic attacks may address this problem. Critical to this approach are methods for capturing physiological arousal during an attack. Herein, we validate an algorithm for capturing physiological arousal using smartphone video of the fingertip. Results demonstrate that the algorithm is able to estimate heart rates that are highly correlated with ECG-derived values (r > 0.99), effectively reject low-quality data often captured outside of controlled laboratory environments (AUC > 0.90), and resolve the physiological arousal experienced during a panic attack. Moreover, patient reported measures indicate that this measurement modality is feasible during panic attacks, and the act of taking the measurement may stop the attack. These results point toward the need for future development and clinical evaluation of this mHealth intervention for preventing panic attacks.