Katarzyna Siuzdak

Dr. Katarzyna Siuzdak

The Szewalski Institute of Fluid-Flow Machinery of the Polish Academy of Sciences (IMP PAN), Gdansk, Poland
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
KSKatarzyna Siuzdak
Katarzyna Siuzdak
Mariusz SzkodaMariusz Szkoda
Mariusz Szkoda
MSMiroslaw Sawczak
Miroslaw Sawczak
ALAnna Lisowska-Oleksiak
Anna Lisowska-Oleksiak
JKJakub Karczewski
Jakub Karczewski
Jacek RylJacek Ryl
Jacek Ryl
The paper discusses the synthesis and performance of iodine doped titania nanotube arrays exhibited under irradiation. The doping procedure was performed as an additional, electrochemical process carried out after formation of nanotube arrays via anodization of the Ti substrate. The optical and structural properties were characterized using Raman, UV-vis, photoluminescence and X-ray photoelectron spectroscopy. The surface morphology and cross-section studies performed by means of scanning electron microscopy show that the ordered tubular architecture is not influenced by the doping method. However, iodine doping causes a reduction of bandgap energy and photoluminescence intensity. The nanotubular TiO2 electrodes have been monitored by electrochemical (using cyclic voltammetry and electrochemical impedance spectroscopy) and in situ UV-vis spectroelectrochemical measurements in contact with an aqueous electrolyte. Collected results show significant differences in electrochemical activity between pure and doped titania exhibited as i.e. change of Mott–Schottky relation or shift in the onset potential when a decrease in reflectance is initiated. The photocurrent density reached 155.2 and 142.2 μA cm−2 for iodine doped materials when KI and HIO4 were used as iodine precursors whereas only 25.6 μA cm−2 was registered for pure titania nanotubes under UV-vis illumination. Moreover, doped samples are far more efficient for the photodegradation progress than undoped material leading to decomposition of over 70% of methylene blue used as a model organic pollutant. The reported studies demonstrate for the first time the detailed optical, electrochemical and photoelectrochemical studies of iodine doped nanotube arrays.

2 June 2014 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
KSKatarzyna Siuzdak
Katarzyna Siuzdak
MSMiroslaw Sawczak
Miroslaw Sawczak
MKM. Klein
M. Klein
Grzegorz NowaczykGrzegorz Nowaczyk
Grzegorz Nowaczyk
Stefan  JurgaStefan Jurga
Stefan Jurga
ACA. Cenian
A. Cenian
We report on the preparation method of nanocrystalline titanium dioxide modified with platinum by using nanosecond laser ablation in liquid (LAL). Titania in the form of anatase crystals has been prepared in a two-stage process. Initially, irradiation by laser beam of a titanium metal plate fixed in a glass container filled with deionized water was conducted. After that, the ablation process was continued, with the use of a platinum target placed in a freshly obtained titania colloid. In this work, characterization of the obtained nanoparticles, based on spectroscopic techniques – Raman, X-ray photoelectron and UV-vis reflectance spectroscopy – is given. High resolution transmission electron microscopy was used to describe particle morphology. On the basis of photocatalytic studies we observed the rate of degradation process of methylene blue (MB) (a model organic pollution) in the presence of Pt modified titania in comparison to pure TiO2 – as a reference case. Physical and chemical mechanisms of the formation of platinum modified titania are also discussed here. Stable colloidal suspensions containing Pt modified titanium dioxide crystalline anatase particles show an almost perfect spherical shape with diameters ranging from 5 to 30 nm. The TiO2 nanoparticles decorated with platinum exhibit much higher (up to 30%) photocatalytic activity towards the degradation of MB under UV illumination than pure titania.

27 January 2015 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
KSKatarzyna Siuzdak
Katarzyna Siuzdak
Mariusz SzkodaMariusz Szkoda
Mariusz Szkoda
MSMiroslaw Sawczak
Miroslaw Sawczak
ALAnna Lisowska-Oleksiak
Anna Lisowska-Oleksiak
Nitrogen doped titania nanotubes were successfully sensitized by the electrochemical method, i.e. as-anodized titania was immersed in different amine (diethylenetriamine – DETA, triethylamine – TEA, and ethylenediamine – EDA) and urea (U) solutions and a constant potential was applied. The highly ordered morphology of fabricated N-TiO2 was investigated by scanning electron microscopy. Spectroscopic techniques, i.e. UV-Vis spectroscopy, Raman spectroscopy, X-ray photoelectron spectroscopy and photoluminescence spectroscopy, were utilized to characterize absorbance capability and the crystalline phase, to confirm the presence of nitrogen atoms and to study charge recombination, respectively. The highest photocurrent under both UV-Vis and visible illumination (λ > 420 nm) was registered for the N-TiO2 sample obtained from diethylenetriamine solution, used as a nitrogen precursor. The photocurrent density exhibited during UV-Vis irradiation by the most active nitrogen doped titania was 2.83 times higher compared to pure TiO2 nanotubes. The photocatalytic activity studies demonstrated a significant improvement when N-TiO2–DETA (52%) and N-TiO2–U samples (49%) where used instead of undoped TiO2 (27%). The presented results show that electrochemical doping with 0.5 M amine or urea solutions is a simple, cheap and effective strategy to introduce nitrogen atoms into the titania structure without affecting its morphology.

28 April 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
WLWiktoria Lipińska
Wiktoria Lipińska
KGKatarzyna Grochowska
Katarzyna Grochowska
KSKatarzyna Siuzdak
Katarzyna Siuzdak
More than 50 years have passed since Clark and Lyon developed the concept of glucose biosensors. Extensive research about biosensors has been carried out up to this day, and an exponential trend in this topic can be observed. The scope of this review is to present various enzyme immobilization methods on gold nanoparticles used for glucose sensing over the past five years. This work covers covalent bonding, adsorption, cross-linking, entrapment, and self-assembled monolayer methods. The experimental approach of each modification as well as further results are described. Designated values of sensitivity, the limit of detection, and linear range are used for the comparison of immobilization techniques.

1 April 2015 in Optical Materials
Verified
Journal Article
Closed access
MSMichał Sobaszek
Michał Sobaszek
LSLukasz Skowronski
Lukasz Skowronski
RBRobert Bogdanowicz
Robert Bogdanowicz
KSKatarzyna Siuzdak
Katarzyna Siuzdak
ACAnna Cirocka
Anna Cirocka
PPP. Płotka
P. Płotka

9 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZCZofia Cebula
Zofia Cebula
SNSabina Nidzworska
Sabina Nidzworska
KDKarolina Dziąbowska
Karolina Dziąbowska
MSMarta Skwarecka
Marta Skwarecka
Natalia MalinowskaNatalia Malinowska
Natalia Malinowska
DNDawid Nidzworski
Dawid Nidzworski
The present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA). Sensor development was characterized by cyclic voltammetry (CV) and antigen detection by electrochemical impedance spectroscopy (EIS) measurements. Seven analyzed strains of Psl were verified as positive by the reference method (PCR) and this immunoassay, proving sensor specificity. Label-free electrochemical detection was in the linear range 1 × 103–1.2 × 105 CFU/mL (colony-forming unit) with an R2 coefficient of 0.992 and a detection limit (LOD) of 337 CFU/mL. The sensor did not interfere with negative probes like buffers and other bacteria. The assay was proven to be fast (10 min detection) and easy in preparation. The advantage was the simplicity and availability of the verified analyte (whole bacteria) as the method does not require sample pretreatment (e.g., DNA isolation). EIS biosensing technique was chosen as one of the simplest and most sensitive with the least destructive influence on the probes compared to other electrochemical methods.