Catarina Silva Monteiro

Ms. Catarina Silva Monteiro

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2016 in Photonic Sensors
Verified
Journal Article
Open access
PDF file
CMCatarina Silva Monteiro
Catarina Silva Monteiro
MFMarta Ferreira
Marta Ferreira
SSSusana Silva
Susana Silva
JKJens Kobelke
Jens Kobelke
KSKay Schuster
Kay Schuster
Orlando FrazãoOrlando Frazão
Orlando Frazão
A curvature sensor based on an Fabry-Perot (FP) interferometer was proposed. A capillary silica tube was fusion spliced between two single mode fibers, producing an FP cavity. Two FP sensors with different cavity lengths were developed and subjected to curvature and temperature. The FP sensor with longer cavity showed three distinct operating regions for the curvature measurement. Namely, a linear response was shown for an intermediate curvature radius range, presenting a maximum sensitivity of 68.52 pm/m-1. When subjected to temperature, the sensing head produced a similar response for different curvature radii, with a sensitivity varying from 0.84 pm/°C to 0.89 pm/°C, which resulted in a small cross-sensitivity to temperature when the FP sensor was subjected to curvature. The FP cavity with shorter length presented low sensitivity to curvature.

27 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CMCatarina Silva Monteiro
Catarina Silva Monteiro
Maria RaposoMaria Raposo
Maria Raposo
Paulo António Martins Ferreira RibeiroPaulo António Martins Ferreira Ribeiro
Paulo António Martins Ferreira Ribeiro
SSSusana Silva
Susana Silva
Orlando FrazãoOrlando Frazão
Orlando Frazão
A Fabry–Pérot acoustic sensor based on a graphene oxide membrane was developed with the aim to achieve a faster and simpler fabrication procedure when compared to similar graphene-based acoustic sensors. In addition, the proposed sensor was fabricated using methods that reduce chemical hazards and environmental impacts. The developed sensor, with an optical cavity of around 246 µm, showed a constant reflected signal amplitude of 6.8 ± 0.1 dB for 100 nm wavelength range. The sensor attained a wideband operation range between 20 and 100 kHz, with a maximum signal-to-noise ratio (SNR) of 32.7 dB at 25 kHz. The stability and sensitivity to temperatures up to 90 °C was also studied. Moreover, the proposed sensor offers the possibility to be applied as a wideband microphone or to be applied in more complex systems for structural analysis or imaging.

4 May 2017 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
CMCatarina Silva Monteiro
Catarina Silva Monteiro
SSSusana Silva
Susana Silva
Orlando FrazãoOrlando Frazão
Orlando Frazão
Two different sensing structures based on a hollow microsphere Fabry-Perot cavity are proposed. The hollow spheroidal cavities are fabricated resorting only to fusion splicing. The first structure is based on a hollow microsphere located at the fiber end and works as a probe sensor. The structure was subjected to lateral load pressure and presents a sensitivity of 1.56 ± 0.01 nm/N. The second proposed sensor relies on an in-line hollow microsphere. The sensing structure allows the detection of lateral loading, with a sensitivity of 2.62 ± 0.02 nm/N, as well as strain detection, with a sensitivity of 4.66 ± 0.03 pm/με. The two proposed sensors present similar response when subjected to temperature and have low thermal sensitivity.

13 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CMCatarina Silva Monteiro
Catarina Silva Monteiro
ARAntónio V. Rodrigues
António V. Rodrigues
DVDuarte Viveiros
Duarte Viveiros
CLCassiano Linhares
Cassiano Linhares
HMHélder Mendes
Hélder Mendes
Orlando FrazãoOrlando Frazão
Orlando Frazão
Power transformers are central elements of power transmission systems and their deterioration can lead to system failures, causing major disruptions in service. Catastrophic failures can occur, posing major environmental hazards due to fires, explosions, or oil spillage. Early fault detection can be accomplished or estimated using electrical sensors or a chemical analysis of oil or gas samples. Conventional methods are incapable of real-time measurements with a low electrical noise due to time-consuming analyses or susceptibility to electromagnetic interference. Optical fiber sensors, passive elements that are immune to electromagnetic noise, are capable of structural monitoring by being enclosed in power transformers. In this work, optical fiber sensors embedded in 3D printed structures are studied for vibration monitoring. The fiber sensor is encapsulated between two pressboard spacers, simulating the conditions inside the power transformer, and characterized for vibrations with frequencies between 10 and 800 Hz, with a constant acceleration of 10 m/s2. Thermal aging and electrical tests are also accomplished, aiming to study the oil compatibility of the 3D printed structure. The results reported in this work suggest that structural monitoring in power transformers can be achieved using optical fiber sensors, prospecting real-time monitoring.

13 May 2022 in Photonics
Verified
Journal Article
Open access
PDF file
Daniela SilvaDaniela Silva
Daniela Silva
CMCatarina Silva Monteiro
Catarina Silva Monteiro
SSSusana Silva
Susana Silva
Orlando FrazãoOrlando Frazão
Orlando Frazão
JPJoana Vaz Pinto
Joana Vaz Pinto
Susana SérioSusana Sério
Susana Sério
Thin films of titanium dioxide (TiO2) and titanium (Ti) were deposited onto glass and optical fiber supports through DC magnetron sputtering, and their transmission was characterized with regard to their use in optical fiber-based sensors. Deposition parameters such as oxygen partial pressure, working pressure, and sputtering power were optimized to attain films with a high reflectance. The films deposited on glass supports were characterized by UV-Vis spectroscopy, X-ray diffraction (XRD), and scanning electron microscopy (SEM). Regarding the deposition parameters, all three parameters were tested simultaneously, changing the working pressure, the sputtering power, and the oxygen percentage. It was possible to conclude that a lower working pressure and higher applied power lead to films with a higher reflectance. Through the analysis of the as-sputtered thin films using X-ray diffraction, the deposition of both Ti and TiO2 films was confirmed. To study the applicability of TiO2 and Ti in fiber sensing, several thin films were deposited in single mode fibers (SMFs) using the sputtering conditions that revealed the most promising results in the glass supports. The sputtered TiO2 and Ti thin films were used as mirrors to increase the visibility of a low-finesse Fabry–Perot cavity and the possible sensing applications were studied.

30 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CCCristina Cunha
Cristina Cunha
CMCatarina Silva Monteiro
Catarina Silva Monteiro
AVAntónio Vaz
António Vaz
SSSusana Silva
Susana Silva
Orlando FrazãoOrlando Frazão
Orlando Frazão
SNSusana Novais
Susana Novais
This paper presents an approach to enhancing sensitivity in optical sensors by integrating self-image theory and graphene oxide coating. The sensor is specifically engineered to quantitatively assess glucose concentrations in aqueous solutions that simulate the spectrum of glucose levels typically encountered in human saliva. Prior to sensor fabrication, the theoretical self-image points were rigorously validated using Multiphysics COMSOL 6.0 software. Subsequently, the sensor was fabricated to a length corresponding to the second self-image point (29.12 mm) and coated with an 80 µm/mL graphene oxide film using the Layer-by-Layer technique. The sensor characterization in refractive index demonstrated a wavelength sensitivity of 200 ± 6 nm/RIU. Comparative evaluations of uncoated and graphene oxide-coated sensors applied to measure glucose in solutions ranging from 25 to 200 mg/dL showed an eightfold sensitivity improvement with one bilayer of Polyethyleneimine/graphene. The final graphene oxide-based sensor exhibited a sensitivity of 10.403 ± 0.004 pm/(mg/dL) and demonstrated stability with a low standard deviation of 0.46 pm/min and a maximum theoretical resolution of 1.90 mg/dL.