Presently, a criticality safety evaluation methodology for the final geological disposal of Swiss spent nuclear fuel is under development at the Paul Scherrer Institute in collaboration with the Swiss National Technical Competence Centre in the field of deep geological disposal of radioactive waste. This method in essence pursues a best estimate plus uncertainty approach and includes burnup credit. Burnup credit is applied by means of a computational scheme called BUCSS-R (Burnup Credit System for the Swiss Reactors–Repository case) which is complemented by the quantification of uncertainties from various sources. BUCSS-R consists in depletion, decay and criticality calculations with CASMO5, SERPENT2 and MCNP6, respectively, determining the keff eigenvalues of the disposal canister loaded with the Swiss spent nuclear fuel assemblies. However, the depletion calculation in the first and the criticality calculation in the third step, in particular, are subject to uncertainties in the nuclear data input. In previous studies, the effects of these nuclear data-related uncertainties on obtained keff values, stemming from each of the two steps, have been quantified independently. Both contributions to the overall uncertainty in the calculated keff values have, therefore, been considered as fully correlated leading to an overly conservative estimation of total uncertainties. This study presents a consistent approach eliminating the need to assume and take into account unrealistically strong correlations in the keff results. The nuclear data uncertainty quantification for both depletion and criticality calculation is now performed at once using one and the same set of perturbation factors for uncertainty propagation through the corresponding calculation steps of the evaluation method. The present results reveal the overestimation of nuclear data-related uncertainties by the previous approach, in particular for spent nuclear fuel with a high burn-up, and underline the importance of consistent nuclear data uncertainty quantification methods. However, only canister loadings with UO2 fuel assemblies are considered, not offering insights into potentially different trends in nuclear data-related uncertainties for mixed oxide fuel assemblies.
This paper presents the steady state analysis of the Rostov-II benchmark using the conventional two-step approach. It involves the STREAM/RAST-K and CASMO-5/PARCS code systems. This paper documents a comprehensive code-to-code comparison between Serpent 2, CASMO-5, and STREAM at the lattice level for the different fuel assemblies (FAs) loaded in the Rostov-II core; and between Serpent 2, PARCS, and RAST-K at the core level in 2D. Finally, the 3D results of both deterministic models are compared to the steady state measurements of the Rostov-II benchmark. With respect to the measurements available in the Rostov-II benchmark, comparable accuracy (30 ppm difference in boron concentration, 2% assembly power) with an industrial calculation scheme (BIPR8) are reported up to 36.73 EFPDs. The calculations reported in the paper showed that the modeling of the resonance self-shielding in the lattice code as well as the geometrical modeling of the reflector are key for an accurate solution (reducing the in-out power tilt). At the core simulator level, a fairly crude 1D reflector model appears to be enough. Overall, this paper provides the detailed models and conditions used in STREAM/RAST-K and CASMO-5/PARCS, and accurate calculation solution for the Rostov-II benchmark with STREAM/RAST-K and CASMO-5/PARCS compared with measurement.
1 September 2013 in Nuclear Engineering and Design
The possibility of measuring the gas-phase velocity in a two-phase mixture through the use of neutron noise techniques is demonstrated in the zero-power reactor CROCUS of the Ecole Polytechnique Federale de Lausanne. It is the first step toward the experimental validation of an existing theoretical model whose objective is the reconstruction of the void profile in a channel. The use of zero-power research reactors is advantageous due to their clean environment in terms of signal fluctuations. To this end, a channel was installed in the reflector of CROCUS. A two-component mixture is generated inside the channel through the injection of compressed air. The signal fluctuations of neutron detectors located at various axial locations next to the channel are processed to determine the transit time of the gas phase between detectors. Four methods are presented based on the detector signal time series either in the time domain (time correlations between signals) or in the frequency domain (phase of the cross-power spectral density. All four methods returned consistent transit times and similar experimental uncertainty. The largest possible gas injection rates as well as the highest possible neutron flux level improve the visibility of the traveling perturbation and reduce the experimental uncertainty on the transit time for a given acquisition time.