Matthias Frankl

Dr. Matthias Frankl

Paul Scherrer Institut
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MFMatthias Frankl
Matthias Frankl
MHMathieu Hursin
Mathieu Hursin
DRDimitri Rochman
Dimitri Rochman
AVAlexander Vasiliev
Alexander Vasiliev
HFHakim Ferroukhi
Hakim Ferroukhi
Presently, a criticality safety evaluation methodology for the final geological disposal of Swiss spent nuclear fuel is under development at the Paul Scherrer Institute in collaboration with the Swiss National Technical Competence Centre in the field of deep geological disposal of radioactive waste. This method in essence pursues a best estimate plus uncertainty approach and includes burnup credit. Burnup credit is applied by means of a computational scheme called BUCSS-R (Burnup Credit System for the Swiss Reactors–Repository case) which is complemented by the quantification of uncertainties from various sources. BUCSS-R consists in depletion, decay and criticality calculations with CASMO5, SERPENT2 and MCNP6, respectively, determining the keff eigenvalues of the disposal canister loaded with the Swiss spent nuclear fuel assemblies. However, the depletion calculation in the first and the criticality calculation in the third step, in particular, are subject to uncertainties in the nuclear data input. In previous studies, the effects of these nuclear data-related uncertainties on obtained keff values, stemming from each of the two steps, have been quantified independently. Both contributions to the overall uncertainty in the calculated keff values have, therefore, been considered as fully correlated leading to an overly conservative estimation of total uncertainties. This study presents a consistent approach eliminating the need to assume and take into account unrealistically strong correlations in the keff results. The nuclear data uncertainty quantification for both depletion and criticality calculation is now performed at once using one and the same set of perturbation factors for uncertainty propagation through the corresponding calculation steps of the evaluation method. The present results reveal the overestimation of nuclear data-related uncertainties by the previous approach, in particular for spent nuclear fuel with a high burn-up, and underline the importance of consistent nuclear data uncertainty quantification methods. However, only canister loadings with UO2 fuel assemblies are considered, not offering insights into potentially different trends in nuclear data-related uncertainties for mixed oxide fuel assemblies.

1 January 2022 in Journal of Instrumentation
Verified
Journal Article
Open access
JMJ. Maestre
J. Maestre
CBC. Bahamonde
C. Bahamonde
IGI. Lamas Garcia
I. Lamas Garcia
KKK. Kershaw
K. Kershaw
NBNicolo Biancacci
Nicolo Biancacci
MCMarco Calviani
Marco Calviani
Beam Intercepting Devices (BIDs) are essential protection elements for the operation of the Large Hadron Collider (LHC) complex. The LHC internal beam dump (LHC Target Dump Injection or LHC TDI) is the main protection BID of the LHC injection system; its main function is to protect LHC equipment in the event of a malfunction of the injection kicker magnets during beam transfer from the SPS to the LHC. Several issues with the TDI were encountered during LHC operation, most of them due to outgassing from its core components induced by electron cloud effects, which led to limitations of the injector intensity and hence had an impact on LHC availability. The absorbing cores of the TDIs, and of beam intercepting devices in general, need to deal with high thermo-mechanical loads induced by the high intensity particle beams. In addition, devices such as the TDI — where the absorbing materials are installed close to the beam, are important contributors to the accelerator impedance budget. To reduce impedance, the absorbing materials that make up the core must be typically coated with high electrical conductivity metals. Beam impact testing of the coated absorbers is a crucial element of development work to ensure their correct operation. In the work covered by this paper, the behaviour of several metal-coated absorber materials was investigated when exposed to high intensity and high energy proton beams in the HiRadMat facility at CERN. Different coating configurations based on copper and molybdenum, and absorbing materials such as isostatic graphite, Carbon Fibre Composite (CfC) and Silicon Carbide reinforced with Silicon Carbide fibres (SiC-SiC), were tested in the facility to assess the TDI's performance and to extract information for other BIDs using these materials. In addition to beam impact tests and an extensive Post Irradiation Examination (PIE) campaign to assess the performance of the coatings and the structural integrity of the substrates, extensive numerical simulations were carried out.

27 March 2025 in Nuclear Engineering and Design
Verified
Journal Article
Open access
MFMatthias Frankl
Matthias Frankl
LBL. Berry
L. Berry
AVAlexander Vasiliev
Alexander Vasiliev
DRD. Rochman
D. Rochman
HFH. Ferroukhi
H. Ferroukhi
MWM. Wittel
M. Wittel

28 August 2025 in Nuclear Science and Engineering
Verified
Journal Article
Open access
AVAlexander Vasiliev
Alexander Vasiliev
MFMatthias Frankl
Matthias Frankl
DRDimitri Rochman
Dimitri Rochman
HFHakim Ferroukhi
Hakim Ferroukhi