Abdallah Karmalawi

Dr. Abdallah Karmalawi


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Optik
Verified
Journal Article
Closed access
AKAbdallah Karmalawi
Abdallah Karmalawi
DRDiaa A. Rayan
Diaa A. Rayan
MRMohamed M. Rashad
Mohamed M. Rashad

3 February 2021 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
AKAbdallah Karmalawi
Abdallah Karmalawi
AAAlaaeldin A. Abdelmageed
Alaaeldin A. Abdelmageed

1 August 2023 in ACTA IMEKO
Verified
Journal Article
Open access
PDF file
AKAbdallah Karmalawi
Abdallah Karmalawi
This paper presents the design, characterization, and traceability of reference solar panel modules for determining the performance of photovoltaic (PV) modules at standard test conditions (STC). The research introduces an advanced experimental system based on a class AAA pulsed solar simulator to measure the radiometric, electrical performances, and efficiency of PV modules. I-V/P characteristics of three PV modules at different STCs and the associated uncertainty budget of the system were estimated. I-V characteristic and associated parameters including Isc, Voc, Pmax, FF, and efficiency were measured. The radiometric and electrical traceability were discussed, and the relative expanded combined uncertainties were concluded to be 1.62 % (Isc), 0.42 % (Voc), 2.05 % (Pmax), and 2.5% (η), with a coverage factor k = 2. Reference solar panel modules were also used on-site to test the performance of large PV panels, and the results are reported.

13 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Ahmed Abdelhady A. KhalilAhmed Abdelhady A. Khalil
Ahmed Abdelhady A. Khalil
AKAbdallah Karmalawi
Abdallah Karmalawi
Moamen R. A. ElsayedMoamen R. A. Elsayed
Moamen R. A. Elsayed
RERamy El-Bashar
Ramy El-Bashar
HAHamdy Abdelhamid
Hamdy Abdelhamid
Mohamed Farhat O. HameedMohamed Farhat O. Hameed
Mohamed Farhat O. Hameed
Near-infrared (NIR) photodetectors are essential for LiDAR, optical communication, and sensing technologies requiring fast response and low power consumption. This work reports a PN photodiode incorporating a co-sputtered MoS2–Al2O3 composite layer to enhance NIR photoresponse for LiDAR and environmental sensing applications. The composite layer improves device performance through defect passivation, dielectric screening, and modified carrier transport behavior. Under 100 mW·cm−2 illumination at 4 V, the device delivers a photocurrent of 10 mA with a response time of 155 µs, corresponding to an approximately threefold (~300%) improvement compared to a reference structure. Spectral measurements show peak responsivity at 970 nm with extended sensitivity up to 1100 nm. These results indicate that embedding Al2O3 within the MoS2 improves the MoS2/Si interface and facilitates infrared photon absorption in the Si substrate, leading to enhanced vertical carrier collection and reduced recombination compared with conventional surface-passivated MoS2/dielectric layers-based devices. The proposed device demonstrates a low-cost, broadband photodiode architecture suitable for eye-safe LiDAR and environmental monitoring applications.

1 January 2023 in Indian Journal of Pure & Applied Physics
Verified
Journal Article
Closed access
PDF file
AKAbdallah Karmalawi
Abdallah Karmalawi
This article aims to establish a new system for pyranometer calibration traceable to the radiometric chain. Different spectrum high flux LEDs have been used as tunable irradiance sources. The calibration procedure, uncertainty budget, and traceability chain of the solar irradiance measurements are presented. Additionally, the results were evaluated using a reference pyranometer, calibrated traceable to radiometric traceability and World Radiometric Reference (WRR). The uncertainty values are also estimated to be around 1.19 % (k = 2) for LEDs-based pyranometer-pyranometer calibration (WRR traceability), and about 0.68 % ( k = 2 ) for reference standard radiometer based (Radiometric traceability). The deviation between the reference pyranometer and the pyranometer under test was about 0.8% using LED at 655nm for irradiance of 500 W/m2. The sensitivity results have been evaluated by reference standard pyranometer traceable to WRR using a xenon lamp as a solar source, with a deviation of about 1 %.

6 July 2026 in Applied Optics
Verified
Journal Article
Closed access
EEEsraa M. El-Mahdy
Esraa M. El-Mahdy
AKAbdallah Karmalawi
Abdallah Karmalawi
AAAlaaeldin Abdelmageed
Alaaeldin Abdelmageed
SESamira Abd El-Mongy
Samira Abd El-Mongy
NNNadra Nada
Nadra Nada
A compact light-emitting-diode (LED)-based system was developed for spectral responsivity measurements of photodetectors in the visible and near-infrared regions. Arrays of narrowband LEDs provided quasi-monochromatic radiation at discrete wavelengths without the need for monochromators. Responsivity values measured with the LED system were compared with those obtained from a conventional double-monochromator facility. For the blue detector, the relative deviation was about 4% at 450 nm; for the infrared detector, deviations across 800–1100 nm were generally a few percent and about 1.5% at 970 nm. Expanded relative uncertainties were 2.03% at 450 nm and 2.78% at 840 nm (k=2).