The path planning of robot is of great significance for the logistics industry, which helps to improve the efficiency of warehousing, sorting and distribution. On the basis of ant colony algorithm, multi step search strategy is used instead of single step search strategy, pheromone update mechanism is redesigned, and path smoothing is configured to improve the performance of the algorithm. The experimental results show that the improved ant colony algorithm proposed in this paper can plan a shorter optimal path on the 16 * 16 grid logistics storage site, and the path length is saved by 9.21%.
BACKGROUND: Medical image security has been paid more attention in the medical field. OBJECTIVE: In order to achieve a higher security level of medical image encryption, this paper proposes a stream cipher enhanced logic mapping encryption method. METHODS: According to the theory of stream cipher, this method uses Chebyshev map to form encryption key. A series of coding operations are used to set the initial value before image chaos processing. Combining with logical mapping, the original image information is encrypted by chaos from X and Y dimensions. RESULTS: The experimental results show that the NPCR value of the encrypted image is 0.9874 after the blood cells are encrypted. CONCLUSIONS: All four evaluation methods fully prove that this method has excellent encryption performance.
Color, texture, and shape are the common features used for the retrieval systems. However, many medical images have a spot of color information. Therefore, the discriminative texture and shape features should be extracted to obtain a satisfied retrieval result. In order to increase the credibility of the retrieval process, many features can be combined to be used for medical image retrieval. Meanwhile, more features require more processing time, which will decrease the retrieval speed. In this paper, wavelet decomposition is adopted to generate different resolution images. Bag-of-feature, texture, and LBP feature are extracted from three different-level wavelet images. Finally, the similarity measure function is obtained by fusing these three types of features. Experimental results show that the proposed multi-feature fusion method can achieve a higher retrieval accuracy with an acceptable retrieval time.
The precise characterization and measurement of new nanomaterials and nano devices require in situ SEM nanorobotic instrumentation systems, which put forward further technical requirements on nanopositioning techniques of compact structure, cross-scale, nanometer accuracy, high vacuum and non-magnetic environment compatibility, etc. In this work, a novel cross-scale nanopositioning stage was proposed, which combined the advantages of piezoelectric stick-slip positioner and piezoelectric scanner techniques and adopted the idea of macro/micro positioning. A new structure design of a single flexible hinge shared by a small and large PZT was proposed to effectively reduce the size of the positioning stage and achieve millimeter stroke and nanometer motion positioning accuracy. Then, the cross-scale motion generation mechanism of the dual piezoelectric stick-slip drive was studied, the system-level dynamics model of the proposed positioning stages was constructed, and the mechanism design was optimized. Further, a prototype was manufactured and a series of experiments were carried out to test the performance of the stage. The results show that the proposed positioning stage has a maximum motion range of 20 mm and minimum step length of 70 nm under the small piezoceramic ceramic macro-motion stepping mode, and a maximum scanning range of 4.9 μm and motion resolution of 16 nm under the large piezoceramic ceramic micro-motion scanning mode. Moreover, the proposed stage has a compact structure size of 30 × 17 × 8 mm3, with a maximum motion speed of 10 mm/s and maximum load of 2 kg. The experimental results confirm the feasibility of the proposed stage, and nanometer positioning resolution, high accuracy, high speed, and a large travel range were achieved, which demonstrates that the proposed stage has significant performance and potential for many in situ SEM nanorobotic instrument systems.
The piezoelectrically-actuated stick-slip nanopositioning stage (PASSNS) has been applied extensively, and many designs of PASSNSs have been developed. The friction force between the stick-slip surfaces plays a critical role in successful movement of the stage, which influences the load capacity, dynamic performance, and positioning accuracy of the PASSNS. Toward solving the influence problems of friction force, this paper presents a novel stick-slip nanopositioning stage where the flexure hinge-based friction force adjusting unit was employed. Numerical analysis was conducted to estimate the static performance of the stage, a dynamic model was established, and simulation analysis was performed to study the dynamic performance of the stage. Further, a prototype was manufactured and a series of experiments were carried out to test the performance of the stage. The results show that the maximum forward and backward movement speeds of the stage are 1 and 0.7 mm/s, respectively, and the minimum forward and backward step displacements are approximately 11 and 12 nm, respectively. Compared to the step displacement under no working load, the forward and backward step displacements only increase by 6% and 8% with a working load of 20 g, respectively. And the load capacity of the PASSNS in the vertical direction is about 72 g. The experimental results confirm the feasibility of the proposed stage, and high accuracy, high speed, and good robustness to varying loads were achieved. These results demonstrate the great potential of the developed stage in many nanopositioning applications.
BACKGROUND: Key area location is an important content of medical image processing and an important detail of auxiliary medical diagnosis. OBJECTIVE: In this paper, a prior knowledge fusion method based on Haar-like feature and contour feature is proposed to locate and detect key areas in medical images. METHOD: For the image to be processed, six Haar-like features and five contour features are extracted respectively. The improvement of Haar-like feature extraction template better adapts to the complexity of regional structure of medical images. The design of the contour feature extraction process fully reflects the consideration of feature invariance. The two features, together with prior knowledge, are fed into their respective decision makers and final fusers as the basis for determining and locating key regions. RESULTS: The experimental results show that the proposed method has excellent performance in locating key regions of medical images on MRI. When the capacity of the database increases from 10 to 200, the accuracy of locating the key areas of the image to be processed still reaches more than 90%. CONCLUSION: The proposed method realizes the accurate location of the key areas of medical images, which is of great significance for the auxiliary medical diagnosis.