Michael Fridrich

Mr. Michael Fridrich

VSB-TUO
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in IEEE Access
Verified
Journal Article
Open access
MFMarcel Fajkus
Marcel Fajkus
MKM. Kostelansky
M. Kostelansky
MFMichael Fridrich
Michael Fridrich
JCJakub Cubik
Jakub Cubik
SKStanislav Kepak
Stanislav Kepak
JNJan Nedoma
Jan Nedoma
Currently, the use of fiber-optic Bragg gratings in biomedical applications, especially in the field of magnetic resonance imaging (MRI), is becoming popular. In these applications, the fiber Bragg grating (FBG) encapsulation plays a crucial role in terms of the accuracy and reproducibility of the measurements. This paper describes in detail the fabrication method of a prototype FBG sensor, which is realized by encapsulating a Bragg grating between two layers of the MR-compatible material Acrylonitrile Butadiene Styrene (ABS) by 3D printing. The sensor thus created, implemented, for example, on the chest of a human body, enables monitoring of the vital functions of the human body. The paper describes the complete procedure for the creation of the prototype sensor, including strain and temperature dependence, as well as results of long-term experimental measurements against the conventional electrocardiography (ECG) standard. Results based on the objective Bland-Altman (B-A) method confirm that the implemented sensor can be used for reliable monitoring of cardiac activity (>95% based on B-A). Taking into account the single fiber optic cable, its simple implementation, its small size and weight < 5g, the presented sensor represents an interesting alternative to conventional ECG.

23 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Radek MartinekRadek Martinek
Radek Martinek
JVJan Vanus
Jan Vanus
JNJan Nedoma
Jan Nedoma
MFMichael Fridrich
Michael Fridrich
JFJaroslav Frnda
Jaroslav Frnda
AKAleksandra Kawala-Sterniuk
Aleksandra Kawala-Sterniuk
This publication describes an innovative approach to voice control of operational and technical functions in a real Smart Home (SH) environment, where, for voice control within SH, it is necessary to provide robust technological systems for building automation and for technology visualization, software for recognition of individual voice commands, and a robust system for additive noise canceling. The KNX technology for building automation is used and described in the article. The LabVIEW SW tool is used for visualization, data connectivity to the speech recognizer, connection to the sound card, and the actual mathematical calculations within additive noise canceling. For the actual recognition of commands, the SW tool for recognition within the Microsoft Windows OS is used. In the article, the least mean squares algorithm (LMS) and independent component analysis (ICA) are used for additive noise canceling from the speech signal measured in a real SH environment. Within the proposed experiments, the success rate of voice command recognition for different types of additive interference (television, vacuum cleaner, washing machine, dishwasher, and fan) in the real SH environment was compared. The recognition success rate was greater than 95% for the selected experiments.

3 July 2020 in IEEE Access
Verified
Journal Article
Open access
MFMarcel Fajkus
Marcel Fajkus
MFMichael Fridrich
Michael Fridrich
JNJan Nedoma
Jan Nedoma
RKRadana Kahankova
Radana Kahankova
Radek MartinekRadek Martinek
Radek Martinek
JKJakub Kolarik
Jakub Kolarik
This article introduces fiber Bragg grating (FBG) system for monitoring selected traffic flow parameters in urban areas. The system is able to monitor traffic density or speed of cars driving in single lane. The proposed system consists of five Bragg gratings encapsulated in Polydimethylsiloxane polymer and is characterized by easy and inexpensive installation in the milled upper layer of the road covered with an asphalt mixture. The results of first operational tests presented in this study include 3978 passing vehicles of various specifications. The system’s vehicle detection success rate is 99.62%. And further, a mean absolute error 1.35 kph and a relative error 2.62% when measuring vehicle speed.

9 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JNJan Nedoma
Jan Nedoma
MSMartin Stolarik
Martin Stolarik
SKStanislav Kepak
Stanislav Kepak
MPMiroslav Pinka
Miroslav Pinka
Radek MartinekRadek Martinek
Radek Martinek
MFMichael Fridrich
Michael Fridrich
At present, one of the primary tasks of the construction industry is to build transport infrastructure. This concerns both the construction of new bypasses of towns and the repair of existing roads, which are damaged by congestion, especially by freight transport. Whether it is a new building or a reconstruction, it is always very important to choose a suitable method of subsoil treatment. One of the most commonly used methods for soil treatment is currently compaction using vibratory rollers. This method is very effective both in terms of results and due to its low financial demands compared to other methods. Vibration is transmitted to the surrounding rock environment when compacting the subsoil using vibratory rollers. Although the intensity of these vibrations is not as pronounced as in other methods of subsoil treatment, such vibrations can have a significant effect, for example during compaction in urban areas or in an area with the presence of historical objects. Therefore, it is very advisable to monitor the effect of these vibrations on the environment during construction. This paper brings an original experimental comparative study of standard seismic instrumentation with a developed interferometric sensor for the field of monitoring vibrations generated during compaction of subsoil using vibrating rollers. The paper presents time and frequency domain results, as well as attenuation curves, which represent real attenuation of vibrations in a given rock environment. The results presented here show that a system operating on a different physical principle from the one used at present has the potential to replace the existing, very expensive, seismic equipment.

30 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MFMarcel Fajkus
Marcel Fajkus
JNJan Nedoma
Jan Nedoma
Radek MartinekRadek Martinek
Radek Martinek
MFMichael Fridrich
Michael Fridrich
EBEmil Bednar
Emil Bednar
PZPetr Zmij
Petr Zmij
The publication describes the design, production, and practical verification of an alternative pressure sensor suitable for measuring the pressure of gas, based on a combination of fiber-optic technology and 3D printing methods. The created sensor uses FBG (Fiber Bragg Grating) suitably implemented on a movable membrane. The sensor is equipped with a reference FBG to compensate for the effect of ambient temperature on the pressure measurement. The sensor is characterized by its immunity to EM interference, electrical passivity at the measuring point, small size, and resistance to moisture and corrosion. The FBG pressure sensor has a pressure sensitivity of 9.086 pm/mbar in the range from 0 to 9 mbar with a correlation coefficient of 0.9982. The pressure measurement in the specified range shows an average measurement error of 0.049 mbar and a reproducibility parameter of 0.0269 ± 0.0135 mbar.

1 October 2020 in IEEE Access
Verified
Journal Article
Open access
JNJan Nedoma
Jan Nedoma
Radek MartinekRadek Martinek
Radek Martinek
MFMarcel Fajkus
Marcel Fajkus
JBJindrich Brablik
Jindrich Brablik
RKRadana Kahankova
Radana Kahankova
KBKhosrow Behbehani
Khosrow Behbehani
This first-ever study demonstrates the applicability of a fiber Bragg grating (FBG) system for MR cardiac triggering of cardiovascular magnetic resonance at 3 Tesla. The unique patented system senses body movements caused by cardiac activity using a non-invasive ballistocardiography (BCG) sensor. The pilot research compares a novel FBG-based system with clinically used triggering systems based on electrocardiography (ECG) and pulse oximetry (POX). The pilot pre-clinical study was conducted on 8 subjects at a Siemens Prisma 3T MR Scanner. The study compares images from two basic cardiac sequences, TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery), using objective methods and subjective evaluation by clinical experts. The study presents original results that confirm the applicability of optical sensors in the field of cardiac triggering having a number of advantages in comparison to conventional solutions, such as no eddy current interference, ease of placement of the sensor on the patient’s body, and senor reusability. The proposed FBG-based system achieves comparable results with the most frequently used and most accurate ECG-based and POX-based clinical systems. In terms of subjective evaluation by experts, the FBG system outperformed the POX-based system used in clinical practice.