Ageing population is now a global challenge, where physical deterioration is the common feature in elderly people. In addition, the diseases, such as spinal cord injury, stroke, and injury, could cause a partial or total loss of the ability of human locomotion. Thus, assistance is necessary for them to perform safe activities of daily living. Robotic hip exoskeletons are able to support ambulatory functions in elderly people and provide rehabilitation for the patients with gait impairments. They can also augment human performance during normal walking, loaded walking, and manual handling of heavy-duty tasks by providing assistive force/torque. In this article, a systematic review of robotic hip exoskeletons is presented, where biomechanics of the human hip joint, pathological gait pattern, and common approaches to the design of robotic hip exoskeletons are described. Finally, limitations of the available robotic hip exoskeletons and their possible future directions are discussed, which could serve a useful reference for the engineers and researchers to develop robotic hip exoskeletons with practical and plausible applications in geriatric orthopaedics. The past decade has witnessed a remarkable progress in research and development of robotic hip exoskeletons. Our aim is to summarize recent developments of robotic hip exoskeletons for the engineers, clinician scientists and rehabilitation personnel to develop efficient robotic hip exoskeletons for practical and plausible applications.
The ability to sense external force is an important technique for force feedback, haptics and safe interaction control in minimally-invasive surgical robots (MISRs). Moreover, this ability plays a significant role in the restricting refined surgical operations. The wrist joints of surgical robot end-effectors are usually actuated by several long-distance wire cables. Its two forceps are each actuated by two cables. The scope of force sensing includes multidimensional external force and one-dimensional clamping force. This paper focuses on one-dimensional clamping force sensing method that do not require any internal force sensor integrated in the end-effector’s forceps. A new clamping force estimation method is proposed based on a joint torque disturbance observer (JTDO) for a cable-driven surgical robot end-effector. The JTDO essentially considers the variations in cable tension between the actual cable tension and the estimated cable tension using a Particle Swarm Optimization Back Propagation Neural Network (PSO-BPNN) under free motion. Furthermore, a clamping force estimator is proposed based on the forceps’ JTDO and their mechanical relations. According to comparative analyses in experimental studies, the detection resolutions of collision force and clamping force were 0.11 N. The experimental results verify the feasibility and effectiveness of the proposed clamping force sensing method.
17 August 2020 in Journal of Mechanisms and Robotics
This paper illustrates the development and experimental validation of a robotic ankle–foot orthosis (AFO) with a series elastic actuator (SEA) and a magneto-rheological (MR) brake. First, the biomechanics of a human ankle joint during walking is explained. Next, the hardware design of the robotic AFO is introduced, including its mechanical structure, actuator design and configuration, and electronic system. The SEA is primarily composed of an electric motor, a planetary gearbox, a torsion spring, and a pair of bevel gears. The MR brake can modulate the viscosity of the robotic AFO and generate a large braking torque of 21.8 Nm with a low power of 8.8 W. Additionally, the modeling of the robotic AFO is presented, followed by an introduction to its control; several gait evaluation indices are proposed as well. Finally, a pilot study is conducted to verify the effectiveness of the developed robotic AFO. The experimental results demonstrate that the robotic AFO has the potential to provide dorsiflexion assistance, thus preventing foot slap and toe drag, in addition to plantarflexion assistance for the forward propulsion of the body. During a gait cycle, an average power of 0.23 W is harvested, and an 8% improvement in the system energy efficiency is achieved.